Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET

被引:107
|
作者
Ahn, Sangtae [1 ]
Ross, Steven G. [2 ]
Asma, Evren [1 ]
Miao, Jun [2 ]
Jin, Xiao [2 ]
Cheng, Lishui [1 ]
Wollenweber, Scott D. [2 ]
Manjeshwar, Ravindra M. [1 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 15期
关键词
PET; penalized likelihood; image reconstruction; quantitation; MAXIMUM-LIKELIHOOD; EMISSION-TOMOGRAPHY; NOISE PROPERTIES; ORDERED SUBSETS; FDG-PET; RESOLUTION; PERFORMANCE; ALGORITHMS; SEGMENTATION; CONVERGENCE;
D O I
10.1088/0031-9155/60/15/5733
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ordered subset expectation maximization (OSEM) is the most widely used algorithm for clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control image noise and does not necessarily achieve optimal quantitation accuracy. As an alternative to OSEM, we have recently implemented a penalized likelihood (PL) image reconstruction algorithm for clinical PET using the relative difference penalty with the aim of improving quantitation accuracy without compromising visual image quality. Preliminary clinical studies have demonstrated visual image quality including lesion conspicuity in images reconstructed by the PL algorithm is better than or at least as good as that in OSEM images. In this paper we evaluate lesion quantitation accuracy of the PL algorithm with the relative difference penalty compared to OSEM by using various data sets including phantom data acquired with an anthropomorphic torso phantom, an extended oval phantom and the NEMA image quality phantom; clinical data; and hybrid clinical data generated by adding simulated lesion data to clinical data. We focus on mean standardized uptake values and compare them for PL and OSEM using both time-of-flight (TOF) and non-TOF data. The results demonstrate improvements of PL in lesion quantitation accuracy compared to OSEM with a particular improvement in cold background regions such as lungs.
引用
收藏
页码:5733 / 5751
页数:19
相关论文
共 50 条
  • [21] Partial Volume Correction for Penalized-Likelihood Image Reconstruction in Oncological PET Applications
    Ahn, Sangtae
    Asma, Evren
    Ross, Steven G.
    Manjeshwar, Ravindra M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [22] Clinical comparison of FDG PET image reconstruction by ordered subsets expectation maximization (OSEM) and sinogram rebinning with attenuation-weighted osem (AWOSEM).
    Valk, PE
    Rao, J
    Finley, BR
    Farboud, B
    Bruckbauer, T
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 199P - 199P
  • [23] Penalized-Likelihood PET Image Reconstruction Using 3D Structural Convolutional Sparse Coding
    Xie, Nuobei
    Gong, Kuang
    Guo, Ning
    Qin, Zhixing
    Wu, Zhifang
    Liu, Huafeng
    Li, Quanzheng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (01) : 4 - 14
  • [24] Comparison of sinogram- and image-domain penalized-likelihood image reconstruction estimators
    Vargas, Phillip A.
    La Riviere, Patrick J.
    MEDICAL PHYSICS, 2011, 38 (08) : 4811 - 4823
  • [25] Clinical Significance of Bayesian penalized-likelihood and Motion Correction PET Reconstruction Algorithms
    Kaya, G.
    Pala, H.
    Tuncel, M.
    Ugur, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S163 - S163
  • [26] A clinical evaluation of the impact of the Bayesian penalized likelihood reconstruction algorithm on PET FDG metrics
    Vallot, Delphine
    Caselles, Olivier
    Chaltiel, Leonor
    Fernandez, Anthony
    Gabiache, Erwan
    Dierickx, Lawrence
    Zerdoud, Slimane
    Bauriaud, Mathilde
    Courbon, Frederic
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (11) : 979 - 984
  • [27] Comparison of Numerical Convergence Speeds of Convergent and Accelerated Algorithms for Penalized Likelihood PET Image
    Cheng, Lishui
    Asma, Evren
    Ahn, Sangtae
    Manjeshwar, Ravindra M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [28] Regularization parameter selection for penalized-likelihood list-mode image reconstruction in PET
    Zhang, Mengxi
    Zhou, Jian
    Niu, Xiaofeng
    Asma, Evren
    Wang, Wenli
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12): : 5114 - 5130
  • [29] THEORETICAL ANALYSIS OF LESION DETECTABILITY IN PENALIZED MAXIMUM-LIKELIHOOD PATLAK PARAMETRIC IMAGE RECONSTRUCTION USING DYNAMIC PET
    Yang, Li
    Wang, Guobao
    Qi, Jinyi
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1188 - 1191
  • [30] Optimization of Bayesian penalized likelihood reconstruction parameters for quantitative brain Positron Emission Tomography (PET) imaging
    Ribeiro, D.
    Hallett, W.
    Howes, O.
    McCutcheon, R.
    Nour, M.
    Tavares, A. A. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S860 - S861