Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET

被引:107
|
作者
Ahn, Sangtae [1 ]
Ross, Steven G. [2 ]
Asma, Evren [1 ]
Miao, Jun [2 ]
Jin, Xiao [2 ]
Cheng, Lishui [1 ]
Wollenweber, Scott D. [2 ]
Manjeshwar, Ravindra M. [1 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 15期
关键词
PET; penalized likelihood; image reconstruction; quantitation; MAXIMUM-LIKELIHOOD; EMISSION-TOMOGRAPHY; NOISE PROPERTIES; ORDERED SUBSETS; FDG-PET; RESOLUTION; PERFORMANCE; ALGORITHMS; SEGMENTATION; CONVERGENCE;
D O I
10.1088/0031-9155/60/15/5733
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ordered subset expectation maximization (OSEM) is the most widely used algorithm for clinical PET image reconstruction. OSEM is usually stopped early and post-filtered to control image noise and does not necessarily achieve optimal quantitation accuracy. As an alternative to OSEM, we have recently implemented a penalized likelihood (PL) image reconstruction algorithm for clinical PET using the relative difference penalty with the aim of improving quantitation accuracy without compromising visual image quality. Preliminary clinical studies have demonstrated visual image quality including lesion conspicuity in images reconstructed by the PL algorithm is better than or at least as good as that in OSEM images. In this paper we evaluate lesion quantitation accuracy of the PL algorithm with the relative difference penalty compared to OSEM by using various data sets including phantom data acquired with an anthropomorphic torso phantom, an extended oval phantom and the NEMA image quality phantom; clinical data; and hybrid clinical data generated by adding simulated lesion data to clinical data. We focus on mean standardized uptake values and compare them for PL and OSEM using both time-of-flight (TOF) and non-TOF data. The results demonstrate improvements of PL in lesion quantitation accuracy compared to OSEM with a particular improvement in cold background regions such as lungs.
引用
收藏
页码:5733 / 5751
页数:19
相关论文
共 50 条
  • [1] Optimization of image reconstruction for rapid image acquisition by 18F-NaF bone PET: Comparison of OSEM and Bayesian penalized likelihood algorithms
    Yoshii, T.
    Miwa, K.
    Wagatsuma, K.
    Yamaguchi, M.
    Suga, M.
    Kamitaka, Y.
    Yamao, T.
    Hiratsuka, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S869 - S869
  • [2] Penalized maximum likelihood simultaneous longitudinal PET image reconstruction with difference-image priors
    Ellis, Sam
    Reader, Andrew J.
    MEDICAL PHYSICS, 2018, 45 (07) : 3001 - 3018
  • [3] A new fuzzy penalized likelihood method for PET image reconstruction
    Zhou, J
    Shu, HZ
    Luo, LM
    Zhu, HQ
    COMPUTATIONAL AND INFORMATION SCIENCE, PROCEEDINGS, 2004, 3314 : 550 - 555
  • [4] Analysis of Penalized Likelihood Image Reconstruction for Dynamic PET Quantification
    Wang, Guobao
    Qi, Jinyi
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (04) : 608 - 620
  • [5] Standard OSEM vs. regularized PET image reconstruction: qualitative and quantitative comparison using phantom data and various clinical radiopharmaceuticals
    Lantos, Judit
    Mittra, Erik S.
    Levin, Craig S.
    Iagaru, Andrei
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 8 (02): : 110 - 118
  • [6] Impact of the Bayesian penalized likelihood algorithm (Q.Clear®) in comparison with the OSEM reconstruction on low contrast PET hypoxic images
    Texte, Edgar
    Gouel, Pierrick
    Thureau, Sebastien
    Lequesne, Justine
    Barres, Bertrand
    Edet-Sanson, Agathe
    Decazes, Pierre
    Vera, Pierre
    Hapdey, Sebastien
    EJNMMI PHYSICS, 2020, 7 (01)
  • [7] Impact of the Bayesian penalized likelihood algorithm (Q.Clear®) in comparison with the OSEM reconstruction on low contrast PET hypoxic images
    Edgar Texte
    Pierrick Gouel
    Sébastien Thureau
    Justine Lequesne
    Bertrand Barres
    Agathe Edet-Sanson
    Pierre Decazes
    Pierre Vera
    Sébastien Hapdey
    EJNMMI Physics, 7
  • [8] Does Bayesian penalized likelihood reconstruction (Q.Clear) for FDG-PET always outperform image quality of OSEM-based reconstruction?
    Rogasch, J. M. M.
    Hofheinz, F.
    Suleiman, S.
    Lukas, M.
    Amthauer, H.
    Furth, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S781
  • [9] Diagnostic performance of FDG PET/CT for liver lesions by using SUV difference between Bayesian penalized likelihood (BPL) reconstruction and ordered-subsets expectation maximization (OSEM) reconstruction
    Nogami, Munenobu
    Nakabayashi, Mika
    Yairi, Toshiki
    Hashimoto, Tomohisa
    Maeda, Hiroaki
    Takenaka, Daisuke
    Adachi, Shuji
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [10] Impact of Patient Size on Image Quality in Clinical PET with a Convergent Penalized-Likelihood Image Reconstruction Algorithm
    Ahn, Sangtae
    Wangerin, Kristen A.
    Wollenweber, Scott D.
    Ross, Steven G.
    Stearns, Charles W.
    Kinahan, Paul E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,