Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo Measurements

被引:51
|
作者
Itu, Lucian [1 ,2 ]
Sharma, Puneet [1 ]
Ralovich, Kristof [1 ,3 ]
Mihalef, Viorel [1 ]
Ionasec, Razvan [1 ]
Everett, Allen [4 ]
Ringel, Richard [4 ]
Kamen, Ali [1 ]
Comaniciu, Dorin [1 ]
机构
[1] Siemens Corp Res & Technol, Princeton, NJ 08540 USA
[2] Transilvania Univ Brasov, Brasov 500024, Romania
[3] Tech Univ Munich, D-85748 Garching, Germany
[4] Johns Hopkins Univ, Sch Med, Baltimore, MD 21287 USA
关键词
Pressure gradient; CFD; Reduced-order models; Coarctation of aorta; Non-invasive; PC-MRI; PEAK-TO-PEAK; BLOOD-FLOW; ARTERIAL; PRESSURE; SIMULATION; GRADIENT; MODELS;
D O I
10.1007/s10439-012-0715-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a CFD-based approach for the non-invasive hemodynamic assessment of pre- and post-operative coarctation of aorta (CoA) patients. Under our approach, the pressure gradient across the coarctation is determined from computational modeling based on physiological principles, medical imaging data, and routine non-invasive clinical measurements. The main constituents of our approach are a reduced-order model for computing blood flow in patient-specific aortic geometries, a parameter estimation procedure for determining patient-specific boundary conditions and vessel wall parameters from non-invasive measurements, and a comprehensive pressure-drop formulation coupled with the overall reduced-order model. The proposed CFD-based algorithm is fully automatic, requiring no iterative tuning procedures for matching the computed results to observed patient data, and requires approximately 6-8 min of computation time on a standard personal computer (Intel Core2 Duo CPU, 3.06 GHz), thus making it feasible for use in a clinical setting. The initial validation studies for the pressure-drop computations have been performed on four patient datasets with native or recurrent coarctation, by comparing the results with the invasively measured peak pressure gradients recorded during routine cardiac catheterization procedure. The preliminary results are promising, with a mean absolute error of less than 2 mmHg in all the patients.
引用
收藏
页码:669 / 681
页数:13
相关论文
共 50 条
  • [1] Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo Measurements
    Lucian Itu
    Puneet Sharma
    Kristóf Ralovich
    Viorel Mihalef
    Razvan Ionasec
    Allen Everett
    Richard Ringel
    Ali Kamen
    Dorin Comaniciu
    [J]. Annals of Biomedical Engineering, 2013, 41 : 669 - 681
  • [2] COARCTATION OF THE AORTA - NON-INVASIVE HEMODYNAMIC ASSESSMENT BEFORE AND AFTER SURGERY
    WALDMAN, JD
    GOODMAN, AH
    TUMEO, AR
    TURNER, SW
    PAPPELBAUM, SJ
    [J]. PEDIATRIC RESEARCH, 1979, 13 (04) : 353 - 353
  • [3] Non-Invasive Imaging Assessment in Patients with Aortic Coarctation: A Contemporary Review
    Leo, Isabella
    Sabatino, Jolanda
    Avesani, Martina
    Moscatelli, Sara
    Bianco, Francesco
    Borrelli, Nunzia
    De Sarro, Rosalba
    Leonardi, Benedetta
    Calcaterra, Giuseppe
    Surkova, Elena
    Di Salvo, Giovanni
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [4] Validation and Diagnostic Performance of a CFD-Based Non-invasive Method for the Diagnosis of Aortic Coarctation
    Lu, Qiyang
    Lin, Weiyuan
    Zhang, Ruichen
    Chen, Rui
    Wei, Xiaoyu
    Li, Tingyu
    Du, Zhicheng
    Xie, Zhaofeng
    Yu, Zhuliang
    Xie, Xinzhou
    Liu, Hui
    [J]. FRONTIERS IN NEUROINFORMATICS, 2020, 14
  • [5] Subject-specific simulation for non-invasive assessment of aortic coarctation: Towards a translational approach
    Mercuri, Massimiliano
    Wustmann, Kerstin
    von Tengg-Kobligk, Hendrik
    Goksu, Cemil
    Hose, D. Rodney
    Narracott, Andrew
    [J]. MEDICAL ENGINEERING & PHYSICS, 2020, 77 : 69 - 79
  • [6] NON-INVASIVE ASSESSMENT OF AORTIC AND MITRAL REGURGITATION
    OHLSSON, J
    WRANNE, B
    MARKLUND, T
    [J]. EUROPEAN HEART JOURNAL, 1985, 6 (10) : 851 - 857
  • [7] NON-INVASIVE ASSESSMENT OF HEMODYNAMIC AND ELECTROPHYSIOLOGICAL EFFECTS OF MEDIGOXIN
    BURGESS, CD
    WARRINGTON, SJ
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1978, 6 (05) : P441 - P441
  • [8] Non-invasive hemodynamic assessment in critically ill children
    Durand, P.
    Salin, J. Bailly
    Roulleau, P.
    [J]. REANIMATION, 2013, 22 (02): : 164 - 172
  • [9] Is validation of non-invasive hemodynamic measurement devices actually required?
    Salvi, Paolo
    [J]. HYPERTENSION RESEARCH, 2014, 37 (01) : 7 - 9
  • [10] Is validation of non-invasive hemodynamic measurement devices actually required?
    Paolo Salvi
    [J]. Hypertension Research, 2014, 37 : 7 - 9