Can Transcranial Electrical Stimulation Localize Brain Function?

被引:41
|
作者
Karabanov, Anke Ninija [1 ]
Saturnino, Guilherme Bicalho [1 ,2 ]
Thielscher, Axel [1 ,2 ]
Siebner, Hartwig Roman [1 ,3 ,4 ]
机构
[1] Univ Copenhagen, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre Hosp, Hvidovre, Denmark
[2] Tech Univ Denmark, Dept Elect Engn, Copenhagen, Denmark
[3] Univ Copenhagen, Bispebjerg Hosp, Dept Neurol, Copenhagen, Denmark
[4] Univ Copenhagen, Inst Clin Med, Fac Hlth Sci & Med, Copenhagen, Denmark
来源
FRONTIERS IN PSYCHOLOGY | 2019年 / 10卷
关键词
TES; cognition; electric field modeling; non-specific effects; transcranial alternate current stimulation; transcranial direct current stimulation; dosing; GALVANIC VESTIBULAR STIMULATION; MOTOR CORTEX EXCITABILITY; MAGNETIC STIMULATION; TEMPORAL POLE; TDCS; FREQUENCY; INTENSITY; FIELD; FLICKER; NETWORK;
D O I
10.3389/fpsyg.2019.00213
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
Transcranial electrical stimulation (TES) uses constant (TDCS) or alternating currents (TACS) to modulate brain activity. Most TES studies apply low-intensity currents through scalp electrodes (<= 2 mA) using bipolar electrode arrangements, producing weak electrical fields in the brain (< 1 V/m). Low-intensity TES has been employed in humans to induce changes in task performance during or after stimulation. In analogy to focal transcranial magnetic stimulation, TES-induced behavioral effects have often been taken as evidence for a causal involvement of the brain region underlying one of the two stimulation electrodes, often referred to as the active electrode. Here, we critically review the utility of bipolar low-intensity TES to localize human brain function. We summarize physiological substrates that constitute peripheral targets for TES and may mediate subliminal or overtly perceived peripheral stimulation during TES. We argue that peripheral co-stimulation may contribute to the behavioral effects of TES and should be controlled for by "sham" TES. We discuss biophysical properties of TES, which need to be considered, if one wishes to make realistic assumptions about which brain regions were preferentially targeted by TES. Using results from electric field calculations, we evaluate the validity of different strategies that have been used for selective spatial targeting. Finally, we comment on the challenge of adjusting the dose of TES considering dose-response relationships between the weak tissue currents and the physiological effects in targeted cortical areas. These considerations call for caution when attributing behavioral effects during or after low-intensity TES studies to a specific brain region and may facilitate the selection of best practices for future TES studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Invasive and Transcranial Photoacoustic Imaging of the Vascular Response to Brain Electrical Stimulation
    Tsytsarev, Vassiliy
    Yao, Junjie
    Hu, Song
    Li, Li
    Favazza, Christopher P.
    Maslov, Konstantin I.
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [22] Electrical and magnetic stimulation to improve brain function
    Pascual-Leone, Alvaro
    FASEB JOURNAL, 2013, 27
  • [23] Transcranial electrical stimulation nomenclature
    Bikson, Marom
    Esmaeilpour, Zeinab
    Adair, Devin
    Kronberg, Greg
    Tyler, William J.
    Antal, Andrea
    Datta, Abhishek
    Sabel, Bernhard A.
    Nitsche, Michael A.
    Loo, Colleen
    Edwards, Dylan
    Ekhtiari, Hamed
    Knotkova, Helena
    Woods, Adam J.
    Hampstead, Benjamin M.
    Badran, Bashar W.
    Peterchev, Angel V.
    BRAIN STIMULATION, 2019, 12 (06) : 1349 - 1366
  • [24] Transcranial magnetic stimulation can diagnose electrical burn-induced myelopathy
    Seo, Cheong Hoon
    Jang, Ki Un
    Lee, Byoung Chul
    Choi, Ihn-Geun
    Kim, Jong Hyun
    Chun, Wook
    Jeong, Je Hoon
    Kang, Tae-Cheon
    BURNS, 2011, 37 (04) : 687 - 691
  • [25] Can noninvasive brain stimulation enhance function in the ageing brain?
    Vallence, Ann-Maree
    Goldsworthy, Mitchell R.
    JOURNAL OF NEUROPHYSIOLOGY, 2014, 111 (01) : 1 - 3
  • [26] BRAIN ELECTRICAL ACTIVITY IN PATIENTS WITH STROKE UNDER TRANSCRANIAL MAGNETIC STIMULATION THERAPY
    Estrada Vinajera, Genco
    Morales Chacon, Lilia
    Gomez Fernandez, Lazaro
    MUSCLE & NERVE, 2014, 50 (04) : 639 - 639
  • [27] BRAIN ELECTRICAL ACTIVITY IN PATIENTS WITH STROKE UNDER TRANSCRANIAL MAGNETIC STIMULATION THERAPY
    Estrada Vinajera, G.
    Morales Chacon, L.
    Gomez Fernandez, L.
    MUSCLE & NERVE, 2013, 48 (04) : 636 - 636
  • [28] Using transcranial electrical stimulation to enhance cognitive functions in the typical and atypical brain
    Kadosh, Roi Cohen
    TRANSLATIONAL NEUROSCIENCE, 2013, 4 (01) : 20 - 33
  • [29] In Vivo Measurements of Transcranial Electrical Stimulation in Lesioned Human Brain: A Case Report
    Jiang, Hongjie
    Wang, Minmin
    Wu, Dan
    Zhang, Jianmin
    Zhang, Shaomin
    BRAIN SCIENCES, 2022, 12 (11)
  • [30] Changes in spontaneous brain bioelectrical activity during transcranial electrical and electromagnetic stimulation
    Sharova E.V.
    Mel'nikov A.V.
    Novikova M.R.
    Kulikov M.A.
    Grechenko T.N.
    Shekhter E.D.
    Zaslavskii A.Yu.
    Neuroscience and Behavioral Physiology, 2007, 37 (5) : 451 - 457