Whole-slide image analysis outperforms micrograph acquisition for adipocyte size quantification

被引:12
|
作者
Maguire, Anne S. [1 ,2 ]
Woodie, Lauren N. [3 ,4 ]
Judd, Robert L. [2 ]
Martin, Douglas R. [1 ,2 ]
Greene, Michael W. [3 ]
Graff, Emily C. [1 ,5 ]
机构
[1] Auburn Univ, Coll Vet Med, Scott Ritchey Res Ctr, Auburn, AL 36849 USA
[2] Auburn Univ, Coll Vet Med, Dept Anat Physiol & Pharmacol, Auburn, AL 36849 USA
[3] Auburn Univ, Coll Human Sci, Dept Nutr Dietet & Hospitality Management, Auburn, AL 36849 USA
[4] Univ Penn, Dept Med, Inst Diabet Obes & Metab, Div Endocrinol Diabet & Metab,Perelman Sch Med, Philadelphia, PA 19104 USA
[5] Auburn Univ, Coll Vet Med, Dept Pathobiol, Auburn, AL 36849 USA
关键词
Adipose tissue; obesity; diabetes; hypertrophy; hyperplasia; ADIPOSE-TISSUE EXPANDABILITY; INSULIN-RESISTANT; FAT DEPOSITION; CELL SIZE; ENLARGEMENT; OBESITY; NUMBER;
D O I
10.1080/21623945.2020.1823139
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The distinction between biological processes of adipose tissue expansion is crucial to understanding metabolic derangements, but a robust method for quantifying adipocyte size has yet to be standardized. Here, we compared three methods for histological analysisin situ: one conventional approach using individual micrographs acquired by digital camera, and two with whole-slide image analysis pipelines involving proprietary (Visiopharm) and open-source software (QuPath with a novel ImageJ plugin). We found that micrograph analysis identified 10-40 times fewer adipocytes than whole-slide methods, and this small sample size resulted in high variances that could lead to statistical errors. The agreement of the micrograph method to measure adipocyte area with each of the two whole-slide methods was substantially less (R(2)of 0.6644 and 0.7125) than between the two whole-slide methods (R(2)of 0.9402). These inconsistencies were more pronounced in samples from high-fat diet fed mice. While the use of proprietary software resulted in the highest adipocyte count, the lower cost, ease of use, and minimal variances of the open-source software provided a distinct advantage for measuring the number and size of adipocytes. In conclusion, we recommend whole-slide image analysis methods to consistently measure adipocyte area and avoid unintentional errors due to small sample sizes.
引用
收藏
页码:567 / 575
页数:9
相关论文
共 50 条
  • [21] Considerations for Whole-Slide Analysis of Murine Xenografts Experiments
    Bland, Abigail R.
    Ashton, John C.
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2021, 69 (10) : 627 - 631
  • [22] Detection, quantification, and characterization by whole-slide image analysis of bacterial infection by Vibrio aestuarianus, stained by immunohistochemistry, in the pacific oyster Magallana gigas
    Geslin, Valentin
    Parizadeh, Leila
    Travers, Marie-Agnes
    Tomasetti, Luca
    Gulsrud, Thor Ole
    AQUACULTURE, 2025, 598
  • [23] An efficient context-aware approach for whole-slide image classification
    Shen, Hongru
    Wu, Jianghua
    Shen, Xilin
    Hu, Jiani
    Liu, Jilei
    Zhang, Qiang
    Sun, Yan
    Chen, Kexin
    Li, Xiangchun
    ISCIENCE, 2023, 26 (12)
  • [24] Whole slide image analysis quantification in a mouse lung metastasis model
    Sandusky, George E.
    Surface, Ronne
    Tonsing-Carter, Eva
    Silver, Jayne
    Sinn, Tony
    Pollok, Karen
    CANCER RESEARCH, 2014, 74 (19)
  • [25] Validation of mitotic cell quantification via microscopy and multiple whole-slide scanners
    Tabata, Kazuhiro
    Uraoka, Naohiro
    Benhamida, Jamal
    Hanna, Matthew G.
    Sirintrapun, Sahussapont Joseph
    Gallas, Brandon D.
    Gong, Qi
    Aly, Rania G.
    Emoto, Katsura
    Matsuda, Kant M.
    Hameed, Meera R.
    Klimstra, David S.
    Yagi, Yukako
    DIAGNOSTIC PATHOLOGY, 2019, 14 (1)
  • [26] Automated whole slide image analysis for a translational quantification of liver fibrosis
    Cindy Serdjebi
    Karine Bertotti
    Pinzhu Huang
    Guangyan Wei
    Disha Skelton-Badlani
    Isabelle A. Leclercq
    Damien Barbes
    Bastien Lepoivre
    Yury V. Popov
    Yvon Julé
    Scientific Reports, 12
  • [27] Automated whole slide image analysis for a translational quantification of liver fibrosis
    Serdjebi, Cindy
    Bertotti, Karine
    Huang, Pinzhu
    Wei, Guangyan
    Skelton-Badlani, Disha
    Leclercq, Isabelle A.
    Barbes, Damien
    Lepoivre, Bastien
    Popov, Yury, V
    Jule, Yvon
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [28] Protocol for whole-slide image analysis of human multiplexed tumor tissues using QuPath and R
    Franken, Amelie
    Bila, Michel
    Lambrechts, Diether
    STAR PROTOCOLS, 2024, 5 (04):
  • [29] Validation of mitotic cell quantification via microscopy and multiple whole-slide scanners
    Kazuhiro Tabata
    Naohiro Uraoka
    Jamal Benhamida
    Matthew G. Hanna
    Sahussapont Joseph Sirintrapun
    Brandon D. Gallas
    Qi Gong
    Rania G. Aly
    Katsura Emoto
    Kant M. Matsuda
    Meera R. Hameed
    David S. Klimstra
    Yukako Yagi
    Diagnostic Pathology, 14
  • [30] Developing image analysis pipelines of whole-slide images: Pre- and post-processing
    Smith, Byron
    Hermsen, Meyke
    Lesser, Elizabeth
    Ravichandar, Deepak
    Kremers, Walter
    JOURNAL OF CLINICAL AND TRANSLATIONAL SCIENCE, 2021, 5 (01)