In vitro evaluation of clot capture efficiency of an absorbable vena cava filter

被引:8
|
作者
Dria, Stephen J. [1 ]
Eggers, Mitchell D. [1 ,2 ,3 ]
机构
[1] Adient Med, Pearland, TX USA
[2] Baylor Coll Med, Dept Orthoped Surg, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Intervent Radiol, Houston, TX 77030 USA
关键词
DEEP-VEIN THROMBOSIS; PULMONARY-EMBOLISM; VENOUS THROMBOEMBOLISM; COMPLICATIONS; PREVENTION; MANAGEMENT; RATES; VIVO;
D O I
10.1016/j.jvsv.2016.05.006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study was to determine the in vitro dot capture efficiency (CCE) of an investigational absorbable inferior vena cava filter (IVCF) vs the Greenfield IVCF. Methods: Investigational absorbable and Greenfield filters were challenged with polyacrylamide clot surrogates ranging from 3 x 5 to 10 x 24 mm (diameter x length) in a flow loop simulating the venous system. Filters were challenged with clots until CCE standard error of 5% or less was achieved under binomial statistics. Pressure gradients across the filters were measured for the largest size clot, enabling calculation of forces on the filter. Results: The in vitro CCE of the absorbable IVCF was statistically similar to that of the Greenfield filter for all clot sizes apart from the 3 x 10-mm clot, for which there was statistically significant difference between filter CCEs (absorbable filter, 59%; Greenfield filter, 31%; P =.0001). CCE ranged from an average 32% for the 3 x 5-mm clot to 100% for 7 x 10-mm and larger clots for the absorbable IVCF. Pressure gradient across the absorbable filter with 10 x 24-mm clot averaged 0.14 mm Hg, corresponding to a net force on the filter of 2.1 x 10(-3) N, compared with 0.39 mm Hg or 5.8 x 10(-3) N (P <.001) for the Greenfield filter. Conclusions: CCE of the absorbable filter was statistically similar to or an improvement on that of the Greenfield stainless steel filter for all dot sizes tested. CCE of the Greenfield filter in this study aligned with data from previous studies. Given the efficacy of the Greenfield filter in attenuating the risk of pulmonary embolism, the current study suggests that the absorbable filter may be a viable candidate for subsequent human testing.
引用
收藏
页码:472 / 478
页数:7
相关论文
共 50 条
  • [31] Crux® vena cava filter
    Murphy, Erin H.
    Johnson, Eric D.
    Kopchok, George E.
    Fogarty, Thomas J.
    Arko, Frank R.
    EXPERT REVIEW OF MEDICAL DEVICES, 2009, 6 (05) : 477 - 485
  • [32] IN-VITRO EVALUATION OF VENA-CAVA FILTERS
    HAMMER, FD
    ROUSSEAU, HP
    JOFFRE, FG
    SENTENAC, BP
    TRANVAN, T
    BARTHELEMY, RP
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (06) : 869 - 876
  • [33] A review of preclinical absorbable inferior vena cava filters
    Wong, Joanna K. L.
    Tan, Matthew
    Bakhshayesh, Peyman
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (02) : 510 - +
  • [34] Design and evaluation of a novel biodegradable inferior vena cava filter
    Yang, Caihong
    Ma, Fengcang
    Gao, Chenguang
    Kang, Yahong
    Zhang, Guoyi
    Liu, Ping
    Jiang, Hongyan
    Chang, Zhaohua
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2019, 33 (08) : 1060 - 1069
  • [35] In vitro assessment of the hemodynamic effects of a partial occlusion in a vena cava filter
    Couch, GG
    Kim, H
    Ojha, M
    JOURNAL OF VASCULAR SURGERY, 1997, 25 (04) : 663 - 672
  • [36] NEW RETRIEVABLE PERCUTANEOUS VENA-CAVA FILTER - EXPERIMENTAL IN-VITRO AND IN-VIVO EVALUATION
    NEUERBURG, J
    GUNTHER, RW
    RASSMUSSEN, E
    VORWERK, D
    TONN, K
    HANDT, S
    KUPPER, W
    HANSEN, JV
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) : 224 - 229
  • [37] THE VENA TECH FILTER - EVALUATION OF A NEW INFERIOR VENA-CAVA INTERRUPTION DEVICE
    CULL, DL
    WHEELER, JR
    GREGORY, RT
    SNYDER, SO
    GAYLE, RG
    PARENT, FN
    JOURNAL OF CARDIOVASCULAR SURGERY, 1991, 32 (05): : 691 - 696
  • [38] ACUTE THROMBOSIS OF A VENA-CAVA FILTER WITH A CLOT ABOVE THE FILTER - SUCCESSFUL TREATMENT WITH LOW-DOSE UROKINASE
    TARDY, B
    PAGE, Y
    ZENI, F
    LAFOND, P
    DECOUSUS, H
    BERTRAND, JC
    CHEST, 1994, 106 (05) : 1607 - 1609
  • [39] Inferior vena cava filter placement: Preinsertion inferior vena cava imaging
    Matthews, BD
    Joels, CS
    LeQuire, MH
    AMERICAN SURGEON, 2003, 69 (08) : 649 - 653
  • [40] Direct superior vena cava puncture for inferior vena cava filter retrieval
    Deshmukh, Ashwin
    Parmar, Gaurav
    Lozada, Juan Carlos Perez
    Cornman-Homonoff, Joshua
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (04): : 638 - 639