Enhanced sensing of anthraquinone dyes using multiwalled carbon nanotubes modified electrode

被引:7
|
作者
Valarmathi, Munirathinam [1 ]
Gomathi, Anandhan [2 ]
Manisankar, Paramasivam [3 ]
机构
[1] NKR Govt Arts Coll W, Dept Chem, Namakkal 637001, India
[2] Sri KGS Arts Coll, Dept Chem, Srivaikuntam 628619, India
[3] Alagappa Univ, Dept Ind Chem, Karaikkudi 630003, Tamil Nadu, India
关键词
textile dyes; differential pulse stripping voltammetry; glassy carbon electrode; multiwalled carbon nano tube (MWCNT); zeolite (ZE); ALIZARIN-RED-S; STRIPPING VOLTAMMETRIC DETERMINATION; PYROLYTIC-GRAPHITE ELECTRODE; AMPEROMETRIC BIOSENSORS; PASTE ELECTRODE; ELECTROCHEMICAL INVESTIGATIONS; CHLOROTRIAZINE DYES; REACTIVE DYES; ADSORPTION; FILMS;
D O I
10.1080/03067319.2011.629348
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric behaviour of two anthraquinone dyes such as Alizarin Red S (ARS) and Reactive blue 4 (RB4) was investigated at plain glassy carbon electrode (GCE), multiwalled carbon nano tube modified GCE (MWCNT/GCE) and zeolite modified GCE (ZE/GCE) using cyclic voltammetry. Effects of pH, scan rate and concentration were studied. The surface morphology of the modified electrode in the absence and presence of dye molecules was characterized by scanning electron microscopy (SEM). A systematic study on the variation of experimental parameters with differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived. MWCNT/GCE performed well among the three electrode systems and the limit of detection (LOD) was 0.036 mu g?mL-1 for ARS and 0.05 mu g?mL-1 for RB4 on this modified system. Suitability of the differential pulse stripping voltammetric method for the trace determination of textile dyes in effluents was also realized.
引用
收藏
页码:349 / 363
页数:15
相关论文
共 50 条
  • [32] Amperometric hydrazine sensor using a glassy carbon electrode modified with gold nanoparticle-decorated multiwalled carbon nanotubes
    Hamidi, Hassan
    Bozorgzadeh, Somayyeh
    Haghighi, Behzad
    MICROCHIMICA ACTA, 2017, 184 (11) : 4537 - 4543
  • [33] Sensitive determination of hydrazine using poly(phenolphthalein), Au nanoparticles and multiwalled carbon nanotubes modified glassy carbon electrode
    Hatip, Muege
    Kocak, Suleyman
    Dursun, Zekerya
    TURKISH JOURNAL OF CHEMISTRY, 2021, 45 (01) : 167 - +
  • [34] ELECTROCHEMICAL DETERMINATION OF CAPSAICIN AND SILYMARIN USING A GLASSY CARBON ELECTRODE MODIFIED BY GOLD NANOPARTICLE DECORATED MULTIWALLED CARBON NANOTUBES
    Mpanza, Thabani
    Sabela, Myalowenkosi I.
    Mathenjwa, Sanele S.
    Kanchi, Suvardhan
    Bisetty, Krishna
    ANALYTICAL LETTERS, 2014, 47 (17) : 2813 - 2828
  • [35] Sensitive and selective determination of hydrazine using glassy carbon electrode modified with Pd nanoparticles decorated multiwalled carbon nanotubes
    Haghighi, Behzad
    Hamidi, Hassan
    Bozorgzadeh, Somayyeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) : 1411 - 1416
  • [36] Amperometric hydrazine sensor using a glassy carbon electrode modified with gold nanoparticle-decorated multiwalled carbon nanotubes
    Hassan Hamidi
    Somayyeh Bozorgzadeh
    Behzad Haghighi
    Microchimica Acta, 2017, 184 : 4537 - 4543
  • [37] Sensitive detection of sulfasalazine at screen printed carbon electrode modified with functionalized multiwalled carbon nanotubes
    Sadeghi, Susan
    Garmroodi, Aziz
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 727 : 171 - 178
  • [38] Sensitive and selective determination of hydrazine using glassy carbon electrode modified with Pd nanoparticles decorated multiwalled carbon nanotubes
    Behzad Haghighi
    Hassan Hamidi
    Somayyeh Bozorgzadeh
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1411 - 1416
  • [39] Amperometric thrombin aptasensor using a glassy carbon electrode modified with polyaniline and multiwalled carbon nanotubes tethered with a thiolated aptamer
    Zhaohong Su
    Xiaolin Xu
    Haitao Xu
    Yi Zhang
    Chaorong Li
    Yan Ma
    Dongcheng Song
    Qingji Xie
    Microchimica Acta, 2017, 184 : 1677 - 1682
  • [40] Amperometric thrombin aptasensor using a glassy carbon electrode modified with polyaniline and multiwalled carbon nanotubes tethered with a thiolated aptamer
    Su, Zhaohong
    Xu, Xiaolin
    Xu, Haitao
    Zhang, Yi
    Li, Chaorong
    Ma, Yan
    Song, Dongcheng
    Xie, Qingji
    MICROCHIMICA ACTA, 2017, 184 (06) : 1677 - 1682