Incidence and impact of prosthesis-patient mismatch following transcatheter aortic valve implantation

被引:7
|
作者
Seoudy, Hatim [1 ]
Guessefeld, Nathalie [1 ]
Frank, Johanne [1 ]
Freitag-Wolf, Sandra [2 ]
Lutter, Georg [3 ,4 ]
Eden, Matthias [1 ,4 ]
Rangrez, AshrafYusuf [1 ,4 ]
Kuhn, Christian [1 ,4 ]
Frey, Norbert [1 ,4 ]
Frank, Derk [1 ,4 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Internal Med 3, Cardiol & Angiol, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Med Informat & Stat, Kiel, Germany
[3] Univ Hosp Schleswig Holstein, Dept Cardiovasc Surg, Kiel, Germany
[4] DZHK German Ctr Cardiovasc Res, Partner Site Hamburg Kiel Lubeck, Kiel, Germany
关键词
Transcatheter aortic valve implantation; Aortic stenosis; Valvular heart disease; VALVULAR HEART-DISEASE; LOW-RISK PATIENTS; CLINICAL IMPACT; REPLACEMENT; STENOSIS; MORTALITY; INTERMEDIATE; EXPERIENCE;
D O I
10.1007/s00392-018-1394-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe implications of prosthesis-patient mismatch (PPM) in the context of transcatheter aortic valve implantation (TAVI) are still controversial. The objective of our study was thus to investigate theincidence and prognostic impact of PPM after TAVI.MethodsOur analysis included 613 TAVI patients in whom the indexed effective orifice area (iEOA) after TAVI was obtained in vivo using echocardiography. Prosthesis sizing was guided by pre-procedural ECG-gated computed tomography. Based on VARC-2 established criteria for significant PPM (iEOA0.85 cm(2)/m(2) in the setting of BMI<30kg/m(2) and iEOA0.7 cm(2)/m(2) in the context of BMI30kg/m(2)), patients were attributed to a No PPM or a PPM group.ResultsWe observed PPM after TAVI in 192 patients (31.3%) with moderate PPM being present in 150 subjects (24.5%) and severe PPM in 42 patients (6.9%). EuroSCORE, impaired LV function, and male gender were associated with PPM status. The No PPM group was characterized by higher rates of self-expandable valves (40.4% vs. 25.5%, p<0.001). In a multivariate analysis age>81.2 years, chronic obstructive pulmonary disease, peripheral artery disease, impaired LV function, acute kidney failure stage 3 as well as periprocedural myocardial infarction emerged as independent risk predictors for all-cause mortality after TAVI. After a median follow-up of 12.2 months PPM failed to show a significant association with overall survival (79.2% vs. 79.3%,p=0.692).ConclusionsThe incidence of PPM after TAVI seems to be substantially lower than after SAVR. PPM was less common using self-expandable valves. In our analysis, patients with PPM following TAVI did not have higher rates of all-cause mortality.
引用
收藏
页码:660 / 668
页数:9
相关论文
共 50 条
  • [41] Prosthesis-patient mismatch after transcatheter aortic valve implantation: prevalence and prognostic impact with respect to baseline left ventricular function
    Schofer, Niklas
    Deuschl, Florian
    Ruebsamen, Nicole
    Skibowski, Johanna
    Seiffert, Moritz
    Voigtlaender, Lisa
    Schaefer, Andreas
    Schneeberger, Yvonne
    Schirmer, Johannes
    Reichenspurner, Hermann
    Blankenberg, Stefan
    Conradi, Lenard
    Schafer, Ulrich
    [J]. EUROINTERVENTION, 2019, 14 (16) : 1648 - 1655
  • [42] Impact of prosthesis-patient mismatch on hemodynamic and clinical outcomes after transcatheter aortic valve implantation with balloon-expandable valves
    Ewe, S. H.
    Delgado, V.
    Tamborini, G.
    Muratori, M.
    Pepi, M.
    Van der Kley, F.
    Fusari, M.
    Biglioli, P.
    Bax, J. J.
    Marsan, N. A.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 904 - 904
  • [43] Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch
    Kim, Hyo-Hyun
    Lee, Sak
    Joo, Hyun-Chel
    Kim, Jung-Hwan
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Lee, Seung-Hyun
    [J]. ANNALS OF THORACIC SURGERY, 2020, 109 (03): : 661 - 667
  • [44] Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement
    Tasca, G
    Brunelli, F
    Cirillo, M
    DallaTomba, M
    Mhagna, Z
    Troise, G
    Quaini, E
    [J]. ANNALS OF THORACIC SURGERY, 2005, 79 (02): : 505 - 510
  • [45] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prosthesis
    Okuno, Taishi
    Khan, Faisal
    Asami, Masahiko
    Praz, Fabien
    Winkel, Mirjam
    Lanz, Jonas
    Huber, Adrian
    Grani, Christoph
    Raber, Lorenz
    Stortecky, Stefan
    Valgimigli, Marco
    Windecker, Stephan
    Pilgrim, Thomas
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B739 - B739
  • [46] Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact
    Leon del Pino, Maria del Carmen
    Ruiz Ortiz, Martin
    Delgado Ortega, Monica
    Sanchez Fernandez, Jose
    Ferreiro Quero, Carlos
    Duran Jimenez, Enrique
    Romero Moreno, Miguel
    Segura Saint-Gerons, Jose
    Ojeda Pineda, Soledad
    Pan Alvarez-Ossorio, Manuel
    Mesa Rubio, Dolores
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (05): : 827 - 836
  • [47] Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
    Poulin, Frederic
    Yingchoncharoen, Teerapat
    Wilson, William M.
    Horlick, Eric M.
    Genereux, Philippe
    Tuzcu, E. Murat
    Stewart, William
    Osten, Mark D.
    Woo, Anna
    Thavendiranathan, Paaladinesh
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (02):
  • [48] Correction: Prosthesis–patient mismatch after transcatheter aortic valve implantation
    Masaki Miyasaka
    Norio Tada
    [J]. Cardiovascular Intervention and Therapeutics, 2023, 38 : 267 - 267
  • [49] Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact
    María del Carmen León del Pino
    Martín Ruíz Ortiz
    Mónica Delgado Ortega
    José Sánchez Fernández
    Carlos Ferreiro Quero
    Enrique Durán Jiménez
    Miguel Romero Moreno
    José Segura Saint-Gerons
    Soledad Ojeda Pineda
    Manuel Pan Álvarez-Ossorio
    Dolores Mesa Rubio
    [J]. The International Journal of Cardiovascular Imaging, 2019, 35 : 827 - 836
  • [50] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    [J]. GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440