Single-shot femtosecond coherent anti-Stokes Raman-scattering thermometry

被引:78
|
作者
Lang, T [1 ]
Motzkus, M [1 ]
机构
[1] Max Planck Inst Quantum Opt, D-85748 Garching, Germany
关键词
D O I
10.1364/JOSAB.19.000340
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new time-domain single-shot detection technique based on nonresonant femtosecond coherent anti-Stokes Raman scattering is introduced for the determination of temperatures in flames and combustion processes, Chirped probe pulses are used to map the time evolution of the molecular dynamics initiated by a pump and a Stokes pulse onto the spectrum of the coherent anti-Stokes Raman-scattering signal pulses. An analytical description of this mapping process is given, which specifies ranges of linear and nonlinear time-frequency mapping, and an experimental realization is presented for single-shot thermometry on H-2. (C) 2002 Optical Society of America.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 50 条
  • [11] One-dimensional vibrational coherent anti-Stokes Raman-scattering thermometry
    Jonuscheit, J
    Thumann, A
    Schenk, M
    Seeger, T
    Leipertz, A
    OPTICS LETTERS, 1996, 21 (19) : 1532 - 1534
  • [12] SINGLE-PULSE COHERENT ANTI-STOKES RAMAN-SCATTERING
    ROH, WB
    SCHREIBER, PW
    TARAN, JPE
    APPLIED PHYSICS LETTERS, 1976, 29 (03) : 174 - 176
  • [13] COHERENT ANTI-STOKES RAMAN-SCATTERING SPECTROSCOPY
    HUDSON, BS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 175 (MAR): : 30 - 30
  • [14] COHERENT ANTI-STOKES RESONANCE RAMAN-SCATTERING
    HERRMANN, J
    LANDMANN, M
    OPTICAL AND QUANTUM ELECTRONICS, 1979, 11 (02) : 161 - 172
  • [15] Theoretical modeling of single-laser-shot, chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering thermometry
    Richardson, D. R.
    Lucht, R. P.
    Kulatilaka, W. D.
    Roy, S.
    Gord, J. R.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 104 (03): : 699 - 714
  • [16] Theoretical modeling of single-laser-shot, chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering thermometry
    D. R. Richardson
    R. P. Lucht
    W. D. Kulatilaka
    S. Roy
    J. R. Gord
    Applied Physics B, 2011, 104 : 699 - 714
  • [17] GAS THERMOMETRY BY FOURIER-ANALYSIS OF ROTATIONAL COHERENT ANTI-STOKES RAMAN-SCATTERING
    LASSER, T
    MAGENS, E
    LEIPERTZ, A
    OPTICS LETTERS, 1985, 10 (11) : 535 - 537
  • [18] Single-shot interferometric approach to background free broadband coherent anti-Stokes Raman scattering spectroscopy
    Lee, Young Jong
    Cicerone, Marcus T.
    OPTICS EXPRESS, 2009, 17 (01): : 123 - 135
  • [19] Supersonic flow diagnostics by single-shot time-domain coherent anti-Stokes Raman scattering
    Ribet, I
    Scherrer, B
    Bouchardy, P
    Pot, T
    Taran, JP
    Lefebvre, M
    JOURNAL OF RAMAN SPECTROSCOPY, 2000, 31 (8-9) : 689 - 696
  • [20] INVESTIGATION OF BIOMOLECULES BY COHERENT ANTI-STOKES RAMAN-SCATTERING