Experimental study of Perfobond shear connectors in composite construction

被引:68
|
作者
Vianna, J. da. C. [1 ]
de Andrade, S. A. L. [1 ,2 ]
Vellasco, P. C. G. da S. [2 ]
Costa-Neves, L. F. [3 ]
机构
[1] Pontifical Catholic Univ Rio de Janeiro, Dept Civil Engn, PUC Rio, BR-22451900 Gavea, RJ, Brazil
[2] Univ Estado Rio De Janeiro, Dept Struct Engn, UERJ, Rio De Janeiro, Brazil
[3] Univ Coimbra, Dept Civil Engn, ISISE, P-3000 Coimbra, Portugal
关键词
Perfobond connector; Experimental analysis; Composite structural systems; Composite construction; Structural behaviour; Shear transfer; STRUCTURAL RESPONSE;
D O I
10.1016/j.jcsr.2012.11.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental programme of the Perfobond connector structural response. Two series of push-out test are discussed: the first series, consisting of three tests, was conducted using a concrete class C25/30, and was previously published in Vianna et al. (2009)[1], while in the second series, with eight different configurations, with repetition, thus in a total of sixteen tests, concrete class C50/60 was used. The other variables in the tests were the number of holes drilled in the connectors, the presence of reinforcing steel bars at the connector holes and the concrete slab thickness. All the shear connectors had 12.5 mm thickness. The experimental results are presented and discussed, focusing on the shear connector resistance, slip capacity and failure modes. The results are compared with the first series that was presented by Vianna et al. (2009) [1]. In addition, the connector resistances are compared to existing analytical formulations. Finally, an analytical formulation developed in the scope of this study for this specific shear connector type is presented and its performance compared to the test results. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 50 条
  • [31] Shear Behavior of Perfobond Rib Shear Connectors for Pre-fabricated Composite Bridges
    装配式组合梁桥开孔钢板连接件抗剪性能
    2018, Chang'an University (31):
  • [32] Experimental study of PZ shear connectors in composite beams
    Yu, Jie
    Wang, Yu-Hang
    Li, Cheng-Yi
    Tan, Ji-Ke
    Yu, Zhou
    Shen, Qi-Wen
    STRUCTURES, 2025, 75
  • [33] Mechanical behavior of steel-concrete composite decks with perfobond shear connectors
    Allahyari, Hamed
    Dehestani, Mehdi
    Beygi, Morteza H. A.
    Neya, Bahram Navayi
    Rahmani, Ebrahim
    STEEL AND COMPOSITE STRUCTURES, 2014, 17 (03): : 339 - 358
  • [34] Behavior of composite girder with Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Choi, Jaegu
    Park, Se-Jun
    Ahn, Jin-Hee
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 103 : 275 - 289
  • [35] Experimental Study on Flexural Performance of HSS-UHPC Composite Beams with Perfobond Strip Connectors
    He, Shaohua
    Li, Quanfeng
    Yang, Gang
    Zhou, Xuan
    Mosallam, Ayman S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (06)
  • [36] Behaviour of Perfobond shear connectors at high temperatures
    Rodrigues, Joao Paulo C.
    Laim, Luis
    ENGINEERING STRUCTURES, 2011, 33 (10) : 2744 - 2753
  • [37] Research on shear strength of perfobond rib connectors
    Zhu W.
    Cui Y.
    Liu Y.
    Heng J.
    2017, Science Press (38): : 129 - 136
  • [38] Shear behavior and analytical model of perfobond connectors
    Zheng, Shuangjie
    Liu, Yuqing
    Yoda, Teruhiko
    Lin, Weiwei
    STEEL AND COMPOSITE STRUCTURES, 2016, 20 (01): : 71 - 89
  • [39] Experimental and numerical investigations on the flexural behavior of steel-uhpc composite slabs with perfobond rib shear connectors
    Zhou M.
    Xiao J.-L.
    Yang T.-Y.
    Nie J.-G.
    Fan J.-S.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (07): : 19 - 29
  • [40] Experimental Study on the Mechanical Properties of Perfobond Rib Shear Connectors with Steel Fiber High Strength Concrete
    Wu, Fangwen
    Liu, Shuo
    Xue, Chengfeng
    Yang, Kangkang
    Feng, Yanpeng
    Zhang, Hao
    MATERIALS, 2021, 14 (12)