Experimental study of Perfobond shear connectors in composite construction

被引:68
|
作者
Vianna, J. da. C. [1 ]
de Andrade, S. A. L. [1 ,2 ]
Vellasco, P. C. G. da S. [2 ]
Costa-Neves, L. F. [3 ]
机构
[1] Pontifical Catholic Univ Rio de Janeiro, Dept Civil Engn, PUC Rio, BR-22451900 Gavea, RJ, Brazil
[2] Univ Estado Rio De Janeiro, Dept Struct Engn, UERJ, Rio De Janeiro, Brazil
[3] Univ Coimbra, Dept Civil Engn, ISISE, P-3000 Coimbra, Portugal
关键词
Perfobond connector; Experimental analysis; Composite structural systems; Composite construction; Structural behaviour; Shear transfer; STRUCTURAL RESPONSE;
D O I
10.1016/j.jcsr.2012.11.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental programme of the Perfobond connector structural response. Two series of push-out test are discussed: the first series, consisting of three tests, was conducted using a concrete class C25/30, and was previously published in Vianna et al. (2009)[1], while in the second series, with eight different configurations, with repetition, thus in a total of sixteen tests, concrete class C50/60 was used. The other variables in the tests were the number of holes drilled in the connectors, the presence of reinforcing steel bars at the connector holes and the concrete slab thickness. All the shear connectors had 12.5 mm thickness. The experimental results are presented and discussed, focusing on the shear connector resistance, slip capacity and failure modes. The results are compared with the first series that was presented by Vianna et al. (2009) [1]. In addition, the connector resistances are compared to existing analytical formulations. Finally, an analytical formulation developed in the scope of this study for this specific shear connector type is presented and its performance compared to the test results. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 75
页数:14
相关论文
共 50 条
  • [1] Experimental study on behavior of π-type perfobond shear connectors
    Li G.
    Wang Z.
    Yang Z.
    Xu W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (02): : 131 - 141
  • [2] Experimental studies on shear behavior of perfobond connectors
    Xue, Weichen
    Dai, Yan
    Zhou, Liang
    Lu, Yuanchun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (05): : 103 - 111
  • [3] STUDY OF EARTH RETAINING COMPOSITE WALL STRUCTURE WITH PERFOBOND SHEAR CONNECTORS
    Taira, Yohei
    Furuichi, Kosuke
    Ichinomiya, Toshimichi
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 1213 - 1216
  • [4] Feasibility study on triangular perfobond rib shear connectors in composite slab
    Ramasamy, Vetturayasudharsanan
    Govindan, Balaji
    MATERIALS TODAY-PROCEEDINGS, 2020, 21 : 133 - 136
  • [5] Experimental evaluation of the structural response of Perfobond shear connectors
    Candido-Martins, J. P. S.
    Costa-Neves, L. F.
    Vellasco, P. C. G. da S.
    ENGINEERING STRUCTURES, 2010, 32 (08) : 1976 - 1985
  • [6] A PARAMETRIC STUDY OF PERFOBOND RIB SHEAR CONNECTORS
    OGUEJIOFOR, EC
    HOSAIN, MU
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1994, 21 (04) : 614 - 625
  • [7] Experimental study on shear mechanism of perfobond connectors in wind turbines foundation
    Lü W.-R.
    Zhu F.
    Lu B.-R.
    Shi W.-H.
    Zhang J.-Z.
    He X.-K.
    Qing S.-Q.
    Gongcheng Lixue/Engineering Mechanics, 2018, 35 (07): : 127 - 138
  • [8] Experimental Studies on FRP-Concrete Composite Deck with FRP Perfobond Shear Connectors
    Xue, Weichen
    Ge, Chang
    Tan, Yuan
    Wang, Yongsheng
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 219 - 223
  • [9] Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach
    Vianna, J. da. C.
    Costa-Neves, L. F.
    Vellasco, P. C. G. da S.
    de Andrade, S. A. L.
    ENGINEERING STRUCTURES, 2008, 30 (09) : 2381 - 2391
  • [10] Shear strength study of perfobond rib connectors
    Department of Bridge Engineering, Tongji University, Shanghai 200092, China
    Harbin Gongye Daxue Xuebao, 2007, SUPPL. 2 (280-282):