Effect of elaborate plastic hinge definition on the pushover analysis of reinforced concrete buildings

被引:14
|
作者
Eslami, A. [1 ]
Ronagh, H. R. [1 ]
机构
[1] Univ Queensland, Sch Civil Engn, Brisbane, Qld 4072, Australia
来源
关键词
pushover analysis; plastic rotation; hinge properties; nonlinear behavior; defined hinges; FEMA hinges; MOMENT-RESISTING FRAMES; PERFORMANCE-BASED DESIGN; SEISMIC PERFORMANCE; FRP; DUCTILE; MODEL;
D O I
10.1002/tal.1035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to its simplicity, lumped plasticity approach is usually used for nonlinear characterization of reinforced concrete (RC) members in pushover analysis. In this approach, the inelastic force deformation of hinges could be defined as either the nonlinear properties suggested in FEMA-356 and ATC-40 or defined hinges quantified on the basis of the properties of RC members. However, the nonlinear response of RC structures relies heavily on the inelastic properties of the structural members concentrated in the plastic hinges. To provide a comparative study, this paper attempts to show the results of pushover analyses of RC structures modeled on the basis of the FEMA nonlinear hinges and defined hinges. Following the validation of the adopted models, the force-deformation curves of the defined hinges are determined in a rigorous approach considering the material inelastic behavior, reinforcement details and dimensions of the members. For the case studies, two four-story and one eight-story frames are considered in order to represent low-rise and mid-rise buildings with different ductility. Nonlinear responses of both models are elaborated in terms of the inter-story drift, hinging pattern, failure mechanism and the pushover curve. It is confirmed that FEMA hinges underestimate the strength and more importantly the displacement capacity, especially for the frame possessing low ductility. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:254 / 271
页数:18
相关论文
共 50 条
  • [31] Calibration of the Length of the Plastic Hinge for Numerical Models of Reinforced Concrete Members
    Barbagallo, Francesca
    Bosco, Melina
    Floridia, Andrea
    Marino, Edoardo M.
    Panarelli, Dario
    Rossi, Pier Paolo
    Spinella, Nino
    BUILDINGS, 2022, 12 (10)
  • [32] Probabilistic Approach for Estimating Plastic Hinge Length of Reinforced Concrete Columns
    Ning, Chao-Lie
    Li, Bing
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (03)
  • [33] Equivalent plastic hinge length of circular reinforced concrete bridge columns
    1600, Chinese Society of Civil Engineering (49):
  • [34] Shear strength model for plastic hinge region of reinforced concrete column
    Wei W.
    Shao C.
    Huang H.
    Li Z.
    Han G.
    Zhuang W.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (09): : 54 - 64
  • [35] Plastic hinge of reinforced concrete beam based on fiber element model
    Chen Xiaoming
    Duan Jin
    Li Yungui
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2017), 2017, 143 : 46 - 50
  • [36] Impact of Plastic Hinge Properties on Capacity Curve of Reinforced Concrete Bridges
    Shatarat, Nasim
    Shehadeh, Mutasem
    Naser, Mohammad
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2017, 2017
  • [38] On the effect of plastic hinge relocation in RC buildings using CFRP
    Eslami, A.
    Dalalbashi, A.
    Ronagh, H. R.
    COMPOSITES PART B-ENGINEERING, 2013, 52 : 350 - 361
  • [39] A plastic hinge method for static pushover analysis of 3D frame structures
    Damci, Erdem
    Oeztorun, Namik Kemal
    Celik, Tuncer
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2024, 25 (04) : 370 - 391
  • [40] Performance-based Pushover Analysis for Reinforced Concrete Frame
    Zhang, Hui-zhi
    Cui, Ku-qin
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 2426 - +