Effect of elaborate plastic hinge definition on the pushover analysis of reinforced concrete buildings

被引:14
|
作者
Eslami, A. [1 ]
Ronagh, H. R. [1 ]
机构
[1] Univ Queensland, Sch Civil Engn, Brisbane, Qld 4072, Australia
来源
关键词
pushover analysis; plastic rotation; hinge properties; nonlinear behavior; defined hinges; FEMA hinges; MOMENT-RESISTING FRAMES; PERFORMANCE-BASED DESIGN; SEISMIC PERFORMANCE; FRP; DUCTILE; MODEL;
D O I
10.1002/tal.1035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to its simplicity, lumped plasticity approach is usually used for nonlinear characterization of reinforced concrete (RC) members in pushover analysis. In this approach, the inelastic force deformation of hinges could be defined as either the nonlinear properties suggested in FEMA-356 and ATC-40 or defined hinges quantified on the basis of the properties of RC members. However, the nonlinear response of RC structures relies heavily on the inelastic properties of the structural members concentrated in the plastic hinges. To provide a comparative study, this paper attempts to show the results of pushover analyses of RC structures modeled on the basis of the FEMA nonlinear hinges and defined hinges. Following the validation of the adopted models, the force-deformation curves of the defined hinges are determined in a rigorous approach considering the material inelastic behavior, reinforcement details and dimensions of the members. For the case studies, two four-story and one eight-story frames are considered in order to represent low-rise and mid-rise buildings with different ductility. Nonlinear responses of both models are elaborated in terms of the inter-story drift, hinging pattern, failure mechanism and the pushover curve. It is confirmed that FEMA hinges underestimate the strength and more importantly the displacement capacity, especially for the frame possessing low ductility. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:254 / 271
页数:18
相关论文
共 50 条
  • [1] Effects of plastic hinge properties in nonlinear analysis of reinforced concrete buildings
    Inel, Mehmet
    Ozmen, Hayri Baytan
    ENGINEERING STRUCTURES, 2006, 28 (11) : 1494 - 1502
  • [2] Modelling of framed shear walls for pushover analysis of reinforced concrete buildings
    Geevar, Indu
    Sengupta, Amlan K.
    Indian Concrete Journal, 2014, 88 (05): : 58 - 68
  • [3] Constitutive Relationship of FRP Reinforced Column Plastic Hinge Zone Based on Pushover Analysis
    Sheng, Guohua
    Zhu, Fusheng
    Zhang, Jun
    Zhu, Guangshan
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 699 - 703
  • [4] Plastic hinge length of reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2008, 105 (03) : 290 - 300
  • [5] Plastic hinge analysis for lightly reinforced and unconfined concrete structural walls
    Ryan D. Hoult
    Helen M. Goldsworthy
    Elisa Lumantarna
    Bulletin of Earthquake Engineering, 2018, 16 : 4825 - 4860
  • [6] Plastic hinge analysis for lightly reinforced and unconfined concrete structural walls
    Hoult, Ryan D.
    Goldsworthy, Helen M.
    Lumantarna, Elisa
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (10) : 4825 - 4860
  • [7] PUSHOVER ANALYSIS FOR REINFORCED CONCRETE STRUCTURES
    Baciu, Catalin
    ICMT '07: INTERNATIONAL CONFERENCE ON MILITARY TECHNOLOGIES, 2007, : 111 - 117
  • [9] Use of Plastic Hinge Model in Nonlinear Pushover Analysis of a Pile
    Chiou, Jiunn-Shyang
    Yang, Ho-Hsiung
    Chen, Cheng-Hsing
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2009, 135 (09) : 1341 - 1346
  • [10] Assessment of plastic hinge length in reinforced concrete columns
    Pham, Phu-Anh-Huy
    Hung, Chung-Chan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2023,