Cell barrier characterization in transwell inserts by electrical impedance spectroscopy

被引:29
|
作者
Linz, Georg [1 ,2 ]
Djeljadini, Suzana [1 ,2 ]
Steinbeck, Lea [1 ,2 ]
Koese, Gurbet [3 ]
Kiessling, Fabian [3 ]
Wessling, Matthias [1 ,2 ]
机构
[1] DWI Leibniz Inst Interact Mat, Forckenbeckstr 50, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Aachener Verfahrenstech Chem Proc Engn, Forckenbeckstr 51, D-52074 Aachen, Germany
[3] Rhein Westfal TH Aachen, Fac Med, Inst Expt Mol Imaging, D-52074 Aachen, Germany
来源
BIOSENSORS & BIOELECTRONICS | 2020年 / 165卷 / 165期
基金
欧洲研究理事会;
关键词
Caco-2; Membrane capacitance; Electrical impedance spectroscopy (EIS); Sonoporation; Transepithelial electrical resistance (TEER); Transwell insert; APICAL MEMBRANE; LINE CACO-2; CAPACITANCE; RESISTANCE; DECREASE; SYSTEM; AREA;
D O I
10.1016/j.bios.2020.112345
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We describe an impedance-based method for cell barrier integrity testing. A four-electrode electrical impedance spectroscopy (EIS) setup can be realized by simply connecting a commercial chopstick-like electrode (STX-1) to a potentiostat allowing monitoring cell barriers cultivated in transwell inserts. Subsequent electric circuit modeling of the electrical impedance results the capacitive properties of the barrier next to the well-known transepithelial electrical resistance (TEER). The versatility of the new method was analyzed by the EIS analysis of a Caco-2 monolayer in response to (a) different membrane coating materials, (b) two different permeability enhancers ethylene glycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) and saponin, and (c) sonoporation. For the different membrane coating materials, the TEERs of the standard and new protocol coincide and increase during cultivation, while the capacitance shows a distinct maximum for three different surface materials (no coating, Matrigel (R), and collagen I). The permeability enhancers cause a decline in the TEER value, but only saponin alters the capacitance of the cell layer by two orders of magnitude. Hence, cell layer capacitance and TEER represent two independent properties characterizing the monolayer. The use of commercial chopstick-like electrodes to access the impedance of a barrier cultivated in transwell inserts enables remarkable insight into the behavior of the cellular barrier with no extra work for the researcher. This simple method could evolve into a standard protocol used in cell barrier research.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Mechanical, electrical properties and impedance spectroscopy characterization of rammed earth
    Rachid Bouferra
    Amal Hachimi
    Amine Zoubir
    Abdelouahab Knidiri
    Said El Hasri
    Lahcen Essaleh
    Mohamed Waqif
    Arabian Journal of Geosciences, 2022, 15 (17)
  • [22] Electrical impedance spectroscopy detects skin barrier dysfunction in childhood atopic dermatitis
    Sasaki, Mari
    Sundberg, Mathilda
    Frei, Remo
    Ferstl, Ruth
    Heye, Kristina N.
    Willems, Erik P.
    Akdis, Cezmi A.
    Lauener, Roger
    Roduit, Caroline
    ALLERGY, 2024, 79 (01) : 142 - 152
  • [23] On-chip epithelial barrier function assays using electrical impedance spectroscopy
    Sun, Tao
    Swindle, Emily J.
    Collins, Jane E.
    Holloway, Judith A.
    Davies, Donna E.
    Morgan, Hywel
    LAB ON A CHIP, 2010, 10 (12) : 1611 - 1617
  • [24] Electrical Impedance Spectroscopy Quantifies Skin Barrier Function in Organotypic In Vitro Models
    van den Brink, Noa J. M.
    Pardow, Felicitas
    Meesters, Luca D.
    van Vlijmen-Willems, Ivonne
    Rodijk-Olthuis, Diana
    Niehues, Hanna
    Jansen, Patrick A. M.
    Roelofs, Susan H.
    Brewer, Matthew G.
    van den Bogaard, Ellen H.
    Smits, Jos P. H.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2024, 144 (11)
  • [25] ELECTRICAL IMPEDANCE SPECTROSCOPY MICROSYSTEM AS A TOOL FOR CANCER CELL ANALYSIS
    Kim, Hyun Soo
    Cho, Younghak
    Frazier, A. Bruno
    Chen, Zhuo .
    Shin, Dong Moon
    Han, Arum
    NEMB2010: PROCEEDINGS OF THE ASME FIRST GLOBAL CONGRESS ON NANOENGINEERING FOR MEDICINE AND BIOLOGY - 2010, 2010, : 49 - 49
  • [26] Electrical Impedance Spectroscopy Microflow Cytometer for cell viability tests
    Gonzalez-Murillo, J. J.
    Monge-Azemar, M.
    Bartoli, J.
    Flores, A.
    Moreno, M.
    Garcia-Celma, M.
    Romano-Rodriguez, A.
    Svendsen, W.
    Samitier, J.
    Rodriguez-Trujillo, R.
    PROCEEDINGS OF THE 2018 12TH SPANISH CONFERENCE ON ELECTRON DEVICES (CDE), 2018,
  • [27] AN ELECTRICAL MODEL OPTIMIZATION FOR SINGLE CELL FLOW IMPEDANCE SPECTROSCOPY
    Claudel, J.
    Nadi, M.
    Elmazria, O.
    Kourtiche, D.
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2016, 9 (02): : 526 - 536
  • [28] Electrical Impedance Spectroscopy Microflow Cytometer for cell viability tests
    Gonzalez-Murillo, J. J.
    Monge-Azemar, M.
    Bartoli, J.
    Flores, A.
    Moreno, M.
    Garcia-Celma, M.
    Romano-Rodriguez, A.
    Svendsen, W.
    Samitier, J.
    Rodriguez-Trujillo, R.
    PROCEEDINGS OF THE 2018 12TH SPANISH CONFERENCE ON ELECTRON DEVICES (CDE), 2018,
  • [29] Optimization of a Lab on a Chip for Electrical Impedance Spectroscopy Parallel Annulus Test Cell for Electrical Impedance Spectroscopy to minimize uncertainty during measurement
    Ghanshyam, Manjari Jyoti
    Paulson, Kevin
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 763 - 768
  • [30] Improved micro-impedance spectroscopy to determine cell barrier properties
    Sohag, Md Mehadi Hasan
    Nicoud, Olivier
    Amine, Racha
    Khalil-Mgharbel, Abir
    Alcaraz, Jean-Pierre
    Vilgrain, Isabelle
    Martin, Donald K.
    EUROBIOTECH JOURNAL, 2020, 4 (03): : 150 - 155