Fabrication and characterization of titanium-matrix composite with 20 vol% hydroxyapatite for use as heavy load-bearing hard tissue replacement

被引:36
|
作者
Chu, CL [1 ]
Xue, XY
Zhu, JC
Yin, ZD
机构
[1] SE Univ, Dept Mat Sci & Engn, Nanjing 210018, Peoples R China
[2] SE Univ, Zhong Da Hosp, Gen Med Ctr, Nanjing 210009, Peoples R China
[3] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
关键词
D O I
10.1007/s10856-006-7310-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Titanium-matrix composite with 20 vol% HA ceramic was fabricated by hot pressing technique and the microstructure of the composite was studied by transmission electron microscope (TEM). The mechanical and biological properties of the composite were investigated by mechanical and in vivo studies. The experimental results by TEM observation show the bonding state of Ti/HA interface in Ti-20 vol% HA composite with the relative density of 97.86% is good, however, there exists an interfacial transition zone between Ti and HA. In Ti matrix of the composite and pure Ti metal, an interesting substructure comprised of screw dislocations with Burgers vectors b of 1/3 < 1120 > was found. Screw dislocations are straight and regularly distributed, and cross slip can be observed. The subgrain boundaries consist of dislocation network walls with equidistant dislocation lines in the same direction. Elastic modulus and Vicker's hardness of Ti-20 vol%HA composite are 102.6 GPa and 3.41 GPa respectively. Owing to the existence of 20 vol% HA ceramic, bending strength and fracture toughness of the composite decrease sharply to 170.1 MPa and 3.57 MPa.m(1/2) respectively, which are only about 17.5 and 12% of those of pure Ti metal. In vivo studies indicate Ti-20 vol% HA composite has good biocompatibility, and even better osteointegration ability than pure titanium, especially in the early stage after the implantation. In conclusion, Ti-20 vol% HA composite is suitable for heavy load-bearing hard tissue replacement from the point of view of both mechanical properties and biocompatibility. (c) 2006 Springer Science + Business Media, Inc.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 14 条
  • [1] Fabrication and characterization of titanium-matrix composite with 20 vol% hydroxyapatite for use as heavy load-bearing hard tissue replacement
    Chenglin Chu
    Xiaoyan Xue
    Jingchuan Zhu
    Zhongda Yin
    [J]. Journal of Materials Science: Materials in Medicine, 2006, 17 : 245 - 251
  • [2] Fabrication and characterization of hydroxyapatite reinforced with 20 vol % Ti particles for use as hard tissue replacement
    C. Chu
    P. Lin
    Y. Dong
    X. Xue
    J. Zhu
    Z. Yin
    [J]. Journal of Materials Science: Materials in Medicine, 2002, 13 : 985 - 992
  • [3] Fabrication and characterization of hydroxyapatite reinforced with 20 vol % Ti particles for use as hard tissue replacement
    Chu, C
    Lin, P
    Dong, Y
    Xue, X
    Zhu, J
    Yin, Z
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (10) : 985 - 992
  • [4] Fabrication of composite scaffolds using hydroxyapatite, epoxy resin and silica for load-bearing applications
    Alam, Md. Kawcher
    Hossain, Md. Sahadat
    Bahadur, Newaz Mohammed
    Ahmed, Samina
    [J]. MATERIALS ADVANCES, 2024, 5 (16): : 6661 - 6671
  • [5] Load-bearing study and interfacial interactions of hydroxyapatite composite coatings for bone tissue engineering
    Awasthi, Shikha
    Pandey, Sarvesh Kumar
    Gaur, Jeet Kumar
    Srivastava, Chandan
    [J]. MATERIALS CHEMISTRY FRONTIERS, 2022, 6 (24) : 3731 - 3747
  • [6] Fabrication of graded porous titanium-magnesium composite for load-bearing biomedical applications
    Jiang, Guofeng
    Li, Qiuyan
    Wang, Cunlong
    Dong, Jie
    He, Guo
    [J]. MATERIALS & DESIGN, 2015, 67 : 354 - 359
  • [7] A novel composite scaffold consisted of porous titanium and chitosan sponge for load-bearing applications: Fabrication, characterization and cellular activity
    Li, Xiang
    Ma, Xiang-Yu
    Feng, Ya-Fei
    Wang, Lin
    Wang, Chengtao
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2015, 117 : 78 - 84
  • [8] Mechanical and biological properties of hydroxyapatite reinforced with 40 vol. % titanium particles for use as hard tissue replacement
    Chu, CL
    Xue, XY
    Zhu, JC
    Yin, ZD
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (06) : 665 - 670
  • [9] Mechanical and biological properties of hydroxyapatite reinforced with 40 vol. % titanium particles for use as hard tissue replacement
    Chenglin Chu
    Xiaoyan Xue
    Jingchuan Zhu
    Zhongda Yin
    [J]. Journal of Materials Science: Materials in Medicine, 2004, 15 : 665 - 670
  • [10] Porous poly(ε-caprolactone) scaffolds for load-bearing tissue regeneration: Solventless fabrication and characterization
    Allaf, Rula M.
    Rivero, Iris V.
    Abidi, Noureddine
    Ivanov, Ilia N.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (06) : 1050 - 1060