LROC analysis of human detection performance in PET and time-of-flight PET

被引:1
|
作者
Gifford, HC [1 ]
Wells, RG [1 ]
King, MA [1 ]
机构
[1] Univ Massachusetts, Med Ctr, Dept Nucl Med, Worcester, MA 01655 USA
关键词
image quality; objective task assessment; signal-to-noise ratio (SNR); receiver operating characteristic (ROC) study; localization ROC (LROC); position emission tomography (PET); time-of-flight PET (TOFPET);
D O I
10.1117/12.349641
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous investigations into time-of-flight positron emission tomography (TOFPET) have shown that stochastic noise in images can be reduced when the reconstruction process accounts for the differences in detection times of coincidence photons. Among the factors that influence this reduction are the sensitivity and the spatial and temporal resolutions of the TOFPET detectors. Within the framework of a simplified time-of-flight imaging model, we have considered the effect of these factors on task performance for human observers. The task was detection of mediastinal "hot" tumors in simulated images of the chest. There were 14 simulated TOFPET systems and 2 simulated PET systems considered. Image reconstruction was performed using filtered backprojection (FBP) for PET and a modified FBP for TOFPET. Localization receiver operating characteristic (LROC) methodology, in which the observers must detect and locate the tumors, was used. The LROC study gives insight into how TOFPET detector characteristics might improve in order to make possible observer task performance on a par with PET. A comparison of our results to a theoretical result from the literature was also conducted.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 50 条
  • [21] Time Resolution Performance of an Electro-Optical-Coupled PET Detector for Time-of-Flight PET/MRI
    Bieniosek, Matthew F.
    Olcott, Peter D.
    Levin, Craig S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2531 - 2533
  • [22] Evaluation of Fourier rebinning of time-of-flight PET data to non time-of-flight
    Li, Quanzheng
    Cho, S.
    Ahn, S.
    Ren, R.
    Leahy, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [23] Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?
    Giovanni Lucignani
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 969 - 971
  • [24] Experimental evaluation of a simple lesion detection task with time-of-flight PET
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02): : 373 - 384
  • [25] Time-of-flight PET and PET/MRI: recurrent dreams or actual realities?
    Lucignani, Giovanni
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (08) : 969 - 971
  • [26] Design and Performance of a High Spatial Resolution, Time-of-Flight PET Detector
    Krishnamoorthy, Srilalan
    LeGeyt, Benjamin
    Werner, Matthew E.
    Kaul, Madhuri
    Newcomer, F. M.
    Karp, Joel S.
    Surti, Suleman
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1092 - 1098
  • [27] TOFPET 2: A high-performance circuit for PET time-of-flight
    Di Francesco, Agostino
    Bugalho, Ricardo
    Oliveira, Luis
    Rivetti, Angelo
    Rolo, Manuel
    Silva, Jose C.
    Varela, Joao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 194 - 195
  • [28] Development of a detector module for Time-of-Flight PET with improved timing performance
    Niknejad, Tahereh
    Borrego, Ana Rita
    Bugalho, Ricardo
    di Francesco, Agostino
    Ferramacho, Luis
    Leong, Carlos
    Rolo, Manuel
    Silva, Rui
    Silva, Jose C.
    Silveira, Miguel
    Tavernier, Stefaan
    Varela, Joao
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [29] Physical and clinical performance of the mCT time-of-flight PET/CT scanner
    Jakoby, B. W.
    Bercier, Y.
    Conti, M.
    Casey, M. E.
    Bendriem, B.
    Townsend, D. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2375 - 2389
  • [30] State of the art and challenges of time-of-flight PET
    Conti, Maurizio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 1 - 11