LROC analysis of human detection performance in PET and time-of-flight PET

被引:1
|
作者
Gifford, HC [1 ]
Wells, RG [1 ]
King, MA [1 ]
机构
[1] Univ Massachusetts, Med Ctr, Dept Nucl Med, Worcester, MA 01655 USA
关键词
image quality; objective task assessment; signal-to-noise ratio (SNR); receiver operating characteristic (ROC) study; localization ROC (LROC); position emission tomography (PET); time-of-flight PET (TOFPET);
D O I
10.1117/12.349641
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous investigations into time-of-flight positron emission tomography (TOFPET) have shown that stochastic noise in images can be reduced when the reconstruction process accounts for the differences in detection times of coincidence photons. Among the factors that influence this reduction are the sensitivity and the spatial and temporal resolutions of the TOFPET detectors. Within the framework of a simplified time-of-flight imaging model, we have considered the effect of these factors on task performance for human observers. The task was detection of mediastinal "hot" tumors in simulated images of the chest. There were 14 simulated TOFPET systems and 2 simulated PET systems considered. Image reconstruction was performed using filtered backprojection (FBP) for PET and a modified FBP for TOFPET. Localization receiver operating characteristic (LROC) methodology, in which the observers must detect and locate the tumors, was used. The LROC study gives insight into how TOFPET detector characteristics might improve in order to make possible observer task performance on a par with PET. A comparison of our results to a theoretical result from the literature was also conducted.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 50 条
  • [1] Detection performance analysis for time-of-flight PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22): : 6931 - 6950
  • [2] DETECTION PERFORMANCE ANALYSIS FOR TIME-OF-FLIGHT PET
    Cao, Nannan
    Huesman, Ronald H.
    Moses, William W.
    Qi, Jinyi
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 402 - +
  • [3] Time-of-Flight PET
    Lewellen, TK
    SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (03) : 268 - 275
  • [4] Impact of Time-of-Flight on PET Tumor Detection
    Kadrmas, Dan J.
    Casey, Michael E.
    Conti, Maurizio
    Jakoby, Bjoern W.
    Lois, Cristina
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) : 1315 - 1323
  • [5] Performance of the Tachyon Time-of-Flight PET Camera
    Peng, Q.
    Choong, W. -S.
    Vu, C.
    Huber, J. S.
    Janecek, M.
    Wilson, D.
    Huesman, R. H.
    Qi, Jinyi
    Zhou, Jian
    Moses, W. W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 111 - 119
  • [6] PET Performance of the GEMINI TF: A Time-of-flight PET/CT Scanner
    Muzic, Raymond F., Jr.
    Kolthammer, Jeffrey A.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1940 - 1944
  • [7] Advances in time-of-flight PET
    Surti, Suleman
    Karp, Joel S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 12 - 22
  • [8] Imaging Performance of the Tachyon Time-of-Flight PET Camera
    Peng, Q.
    Choong, W. -S.
    Vu, C.
    Huber, J. S.
    Janecek, M.
    Wilson, D.
    Huesman, R. H.
    Moses, W. W.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [9] Performance Investigation of a Time-of-Flight PET/CT Scanner
    Jakoby, B. W.
    Bercier, Y.
    Conti, M.
    Casey, M.
    Gremillion, T.
    Hayden, C.
    Bendriem, B.
    Townsend, D. W.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3013 - +
  • [10] Improved Intrinsic Motion Detection Using Time-of-Flight PET
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (10) : 2131 - 2145