This paper presents the results of measurements of indoor radon concentrations in the X-ray rooms of a selection of hospitals in the metropolitan area of Mexico City. The metropolitan area of Mexico City is Mexico's largest metropolitan area by population; the number of patients requiring the use of X-rays is also the highest. An understanding of indoor radon concentrations in X-ray rooms is necessary for the estimation of the radiological risk to which patients, radiologists and medical technicians are exposed. The indoor radon concentrations were monitored for a period of six months using nuclear track detectors (NTD) consisting of a closed-end cup system with CR-39 (Lantrack (R)) polycarbonate as detector material. The indoor radon concentrations were found to be between 75 and 170 Bq m(-3), below the USEPA-recommended indoor radon action level for working places of 400 Bq m(-3). It is hoped that the results of this study will contribute to the establishment of recommended action levels by the Mexican regulatory authorities responsible for nuclear safety.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 50 条
  • [21] A HISTORY OF RADIATION SHIELDING OF X-RAY THERAPY ROOMS
    MCGINLEY, PH
    MINER, MS
    HEALTH PHYSICS, 1995, 69 (05): : 759 - 765
  • [22] ORGANIZATION OF X-RAY DIAGNOSIS IN OPERATING-ROOMS
    KOLLATH, J
    FRANKFUR.AM
    STRNAD, F
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1974, : 420 - 420
  • [23] New and improved method for building x-ray rooms
    Toch, M
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1923, 15 : 229 - 231
  • [24] Monitoring of the shape of the anode voltage curve in X-ray diagnostic apparatuses installed in X-ray rooms
    Shengeliya N.A.
    Biomedical Engineering, 2001, 35 (5) : 279 - 281
  • [25] AN X-RAY SURVEY OF ESKIMOS
    LEWIS, HW
    WHERRETT, GJ
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1947, 57 (04) : 357 - 359
  • [26] WHICH - X-RAY SURVEY
    MCDERMOTT, VGM
    GRIFFIN, TMJ
    CLINICAL RADIOLOGY, 1991, 43 (06) : 435 - 435
  • [27] Perspective article Survey of the distribution of dental X-ray machines in Taiwan's hospitals
    Cheng, Feng-Chou
    Hu, Yu -Ting
    Chiang, Chun -Pin
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (02) : 1270 - 1273
  • [28] Hard X-ray survey for galactic and extragalactic x-ray sources
    Manchanda, RK
    NEW CENTURY OF X-RAY ASTRONOMY, 2001, 251 : 386 - 387
  • [29] IMPROVED X-RAY SERVICE FOR LARGE HOSPITALS
    CLIFTON, VK
    AUSTRALASIAN RADIOLOGY, 1972, 16 (01): : 35 - &
  • [30] Nationwide survey of radon levels in indoor workplaces in Mexico using Nuclear Track Methodology
    Espinosa, G.
    Golzarri, J. I.
    Angeles, A.
    Griffith, R. V.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 1051 - 1054