The Heat Strain of Various Athletic Surfaces: A Comparison Between Observed and Modeled Wet-Bulb Globe Temperatures

被引:25
|
作者
Pryor, J. Luke [1 ,3 ]
Pryor, Riana R. [1 ,2 ,3 ]
Grundstein, Andrew [4 ]
Casa, Douglas J. [3 ]
机构
[1] Calif State Univ, Dept Kinesiol, 5275 North Campus Dr,M-S SG25, Fresno, CA 93740 USA
[2] Calif State Univ, Cent Calif Sports Sci Inst, Fresno, CA USA
[3] Univ Connecticut, Dept Kinesiol, Korey Stringer Inst, Storrs, CT USA
[4] Univ Georgia, Dept Geog, Climatol Res Lab, Athens, GA 30602 USA
关键词
exercise; exertional heat illnesses; environment; activity modification; STANDARD METEOROLOGICAL MEASUREMENTS; ENVIRONMENTAL-CONDITIONS; UNITED-STATES; ILLNESS; STRESS; INDEX; WBGT; MICROCLIMATES; U.S;
D O I
10.4085/1062-6050-52.11.15
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Context: The National Athletic Trainers' Association recommends using onsite wet-bulb globe temperature (WBGT) measurement to determine whether to modify or cancel physical activity. However, not all practitioners do so and instead they may rely on the National Weather Service (NWS) to monitor weather conditions. Objective: To compare regional NWS WBGT estimates with local athletic-surface readings and compare WBGT measurements among various local athletic surfaces. Design: Observational study. Setting: Athletic fields. Main Outcome Measure(s): Measurements from 2 identical WBGT devices were averaged on 10 athletic surfaces within an NWS station reporting radius. Athletic surfaces consisted of red and black all-weather tracks (track), blue and black hard tennis courts (tennis), nylon-knit artificial green turf, green synthetic turfgrass, volleyball sand, softball clay, natural grass (grass), and a natural lake (water). Measurements (n = 143 data pairs) were taken over 18 days (May through September) between 1 PM and 4: 30 PM in direct sunlight 1.2 m above ground. The starting location was counterbalanced across surfaces. The NWS weather data were entered into an algorithm to model NWS WBGT. Results: Black tennis, black track, red track, and volleyball sand WBGT recordings were greater than NWS estimates (P <= .05). When all athletic-surface measurements were combined, NWS (26.85 degrees C +/- 2.93 degrees C) underestimated athletic-surface WBGT measurements (27.52 degrees C +/- 3.13 degrees C; P < .001). The range of difference scores (-4.42 degrees C to 6.14 degrees C) and the absolute mean difference (1.71 degrees C +/- 1.32 degrees C) were large. The difference between the onsite and NWS WBGT measurements resulted in misclassification of the heat-safety activity category 45% (65/143) of the time (chi(2)(1) = 3.857, P = .05). The WBGT of water was 1.4 degrees C to 2.7 degrees C lower than that of all other athletic surfaces (P = .04). We observed no other differences among athletic surfaces but noted large WBGT measurement variability among athletic playing surfaces. Conclusions: Clinicians should use an onsite WBGT device to determine environmental conditions and the need for modification of athletic events, especially as environmental conditions worsen. Given the large WBGT variability among athletic surfaces, WBGT measurements should be obtained from each athletic surface.
引用
收藏
页码:1056 / 1064
页数:9
相关论文
共 50 条
  • [41] Physical modelling of globe and natural wet bulb temperatures to predict WBGT heat stress index in outdoor environments
    Gaspar, Adelio R.
    Quintela, Divo A.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2009, 53 (03) : 221 - 230
  • [42] Evaluation of wet bulb globe temperature index for estimation of heat strain in hot/humid conditions in the Persian Gulf
    Dehghan, Habibolah
    Mortazavi, Seyed Bagher
    Jafari, Mohammad J.
    Maracy, Mohammad R.
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2012, 17 (12): : 1108 - 1113
  • [43] Identifying the need for locally-observed wet bulb globe temperature across outdoor athletic venues for current and future climates in a desert environment
    Guyer, Haven
    Georgescu, Matei
    Hondula, David M.
    Wardenaar, Floris
    Vanos, Jennifer
    ENVIRONMENTAL RESEARCH LETTERS, 2021, 16 (12):
  • [44] A mathematical correction based on weight analysis on instantaneous dry-bulb and wet-bulb temperatures tolerances specified for cooling capacity test and heat pump test
    Zhang, Zhongbin
    Huang, Hu
    Li, Yinglin
    Huang, Yi
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (03) : 261 - 265
  • [45] Investigating wet-bulb globe temperature on heat-related illness in general population for alerting heat exposure: A time-stratified case-crossover study
    Lin, Yi-Chun
    Jung, Chau-Ren
    Hwang, Bing-Fang
    Chen, Chen-Peng
    URBAN CLIMATE, 2025, 59
  • [46] The association between wet-bulb globe temperature and other thermal indices (DI, MDI, PMV, PPD, PHS, PSI and PSIhr): a field study
    Zare, Sajad
    Hasheminejad, Naser
    Bateni, Mokhles
    Baneshi, Mohammad Reza
    Shirvan, Hossein Elahi
    Hemmatjo, Rasoul
    INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, 2020, 26 (01) : 71 - 79
  • [47] Relatively minor influence of individual characteristics on critical wet-bulb globe temperature (WBGT) limits during light activity in young adults (PSU HEAT Project)
    Wolf, S. Tony
    Havenith, George
    Kenney, W. Larry
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 134 (05) : 1216 - 1223
  • [48] Physiological strain under different wet bulb temperatures during daylong humid heat exposure in young men
    Xu, Huijuan
    Zhang, Lei
    Jin, Zhao
    Wang, Aobing
    Liu, Zhijian
    Wang, Faming
    BUILDING AND ENVIRONMENT, 2025, 274
  • [49] Event-Based Heat-Related Risk Assessment Model for South Korea Using Maximum Perceived Temperature, Wet-Bulb Globe Temperature, and Air Temperature Data
    Kang, Misun
    Kim, Kyu Rang
    Shin, Ju-Young
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (08)
  • [50] Potential effect of heat adaptation on association between number of heatstroke patients transported by ambulance and wet bulb globe temperature in Japan
    Oka, Kazutaka
    Honda, Yasushi
    Phung, Vera Ling Hui
    Hijioka, Yasuaki
    ENVIRONMENTAL RESEARCH, 2023, 216