Beam Monitors for Tomorrow: The Challenges of Electron and Photon FLASH RT

被引:22
|
作者
Vignati, Anna [1 ,2 ]
Giordanengo, Simona [2 ]
Fausti, Federico [2 ,3 ]
Villarreal, Oscar A. Marti [1 ,2 ]
Milian, Felix Mas [1 ,4 ]
Mazza, Giovanni [2 ]
Shakarami, Zahra [1 ,2 ]
Cirio, Roberto [1 ,2 ]
Monaco, Vincenzo [1 ,2 ]
Sacchi, Roberto [1 ,2 ]
机构
[1] Univ Torino, Phys Dept, Turin, Italy
[2] INFN Natl Inst Nucl Phys, Turin Div, Turin, Italy
[3] Devices & Technol Torino Srl, DE TEC TOR, Turin, Italy
[4] Univ Estadual Santa Cruz, Dept Exact & Technol Sci DCET, Ilheus, BA, Brazil
关键词
FLASH RT; electron beams; photon beams; beam monitors; silicon detector; DETECTORS; SENSORS; DESIGN;
D O I
10.3389/fphy.2020.00375
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The emergent FLASH RadioTherapy (RT) uses ultrahigh dose-rate irradiation (up to 10(7)Gy/s instantaneous dose-rate in each mu s pulse) to deliver a single high dose of irradiation in a very short time (<200 ms). Pre-clinical studies at ultrahigh dose-rates recently showed an increased ratio between tumoricidal effect and normal tissue toxicity (therapeutic index), compared to conventional RT at standard Gy/min dose-rates. If confirmed by biologicalin vivovalidations, this could represent a breakthrough in cancer treatment. However, the reliability and the accuracy of experimental studies are nowadays limited by the lack of detectors able to measure online the beam fluence at FLASH dose-rates. The behavior of standard beam monitors (gas-filled ionization chambers) is compromised by the volume recombination caused by the amount of charges created per unit volume and unit time, due to the large dose-rate. Moreover, due to the lack of proper monitoring devices and to the uncertainties of its future applications, very few facilities are able to deliver at present FLASH irradiations. In this contribution, we report about the physical and technological challenges of monitoring high and ultra-high dose-rates with electrons and photon beams, starting from the pre-clinical and clinical constraints for new devices. Based on the extensive experience in silicon detectors for monitoring applications in RT with external beams, the work then investigates silicon sensors as a possible option to tackle such extreme requirements and a rugged thin and large (e.g., 10 x 10 cm(2)) flat detector (silicon-based sensor + readout electronics) is therefore outlined. This study aims at presenting the FLASH-RT dosimetry problem and analyzing the possibilities for a silicon sensor to be employed as sensing device for several FLASH scenarios, including some ideas on the readout part. However, more detailed simulations and studies are demanded to delineate more precisely the technical choices to be undertaken in order to tackle the clinical accuracy required on the beam fluence, typically a few %, during photon and electron high and ultra-high irradiations, the required minimal perturbation of the beam and the high level of radiation resistance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Electron beam characterization with beam loss monitors
    Verra, L.
    Turner, M.
    Gessner, S.
    Gschwendtner, E.
    Velotti, F.
    Muggli, P.
    [J]. PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2020, 23 (03):
  • [2] BEAM MONITORS FOR THE PHOTON FACTORY STORAGE RING
    SHIBATA, S
    KATSURA, T
    NAKAGAWA, H
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 113 - 113
  • [3] BEAM PROFILE MONITORS FOR A TAGGED PHOTON-BEAM FACILITY
    ARENDS, J
    BREUER, M
    DAHMEN, HD
    DETEMPLE, P
    SCHNEIDER, W
    URBAN, D
    ZUCHT, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (1-2): : 89 - 92
  • [4] Implementation and validation of a beam-current transformer on a medical pulsed electron beam LINAC for FLASH-RT beam monitoring
    Oesterle, Roxane
    Jorge, Patrik Goncalves
    Grilj, Veljko
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Germond, Jean-Francois
    Bochud, Francois
    Bailat, Claude
    Moeckli, Raphael
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (11): : 165 - 171
  • [5] Resolution studies at beam position monitors at the FLASH facility at DESY
    Baboi, N.
    Lund-Nielsen, J.
    Noelle, D.
    Riesch, W.
    Traber, T.
    Kruse, J.
    Wendtt, M.
    [J]. BEAM INSTRUMENTATION WORKSHOP 2006, 2006, 868 : 227 - +
  • [6] CAMBRIDGE ELECTRON ACCELERATOR BEAM POSITION MONITORS
    LAW, LA
    HOLCOMB, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1965, NS12 (03) : 856 - &
  • [7] The electron beam orbit sensitivity of the photon flux of the photon beam line
    Hsu, I
    Luo, GH
    Tsang, KL
    Chu, CC
    Yu, CI
    Weng, WT
    Chung, SC
    [J]. PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 3364 - 3366
  • [8] An electron beam detector for the FLASH II beam dump
    Good, J.
    Kube, G.
    Leuschner, N.
    Perlick, F.
    Sachwitz, M.
    Schmitz, M.
    Wittenburg, K.
    Wohlenberg, T.
    [J]. ADVANCES IN X-RAY FREE-ELECTRON LASERS II: INSTRUMENTATION, 2013, 8778
  • [9] An electron beam detector for the FLASH II beam dump
    Good, J.
    Kube, G.
    Leuschner, N.
    Perlick, F.
    Sachwitz, M.
    Schmitz, M.
    Wittenburg, K.
    Wohlenberg, T.
    [J]. 11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [10] FLASH RADIOGRAPHY OF ELECTRON BEAM WELDING
    BRYANT, LE
    [J]. MATERIALS EVALUATION, 1971, 29 (10) : 237 - &