Fabrication of CdMnTe semiconductor as radiation detector

被引:13
|
作者
Najam, L. A. [1 ]
Jamil, N. Y. [1 ]
Yousif, R. M. [2 ]
机构
[1] Univ Mosul, Coll Sci, Dept Phys, Mosul 00964, Nineveh, Iraq
[2] Univ Mosul, Coll Environm Sci & Technol, Dept Environm Sci Technol, Mosul 00964, Nineveh, Iraq
关键词
CdMnTe; Gamma ray detector; II-VI materials; MOS device; Energy resolution; GAMMA-RAY DETECTORS; CDZNTE DETECTORS; ION IRRADIATION; X-RAY; FILMS; CRYSTAL; GROWTH;
D O I
10.1007/s12648-012-0051-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this work, devices have been fabricated as to be nuclear detector, from p-CdMnTe. Three devices were prepared: First planar detector with (Au) ohmic contact on both sides; Second as schottky type device of In-CdMnTe with (Au) ohmic contact on the back face; and thirdly metal oxide semiconductor (MOS) device for which the samples annealed under Oxygen flow for (2 h.) at 700 A degrees C, this device (MOS) when connected to conventional nuclear spectroscopy gave reasonable but not high quality signals due to irradiating with Cs-137, Am-241 and (Cs-137 + Am-241). Matlab- software based on numerical methods is used to analyze the data. Resolution through the Full Width at Half Maximum and the area under the peak and the error for this detector are presented.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [31] APPLICATION OF SEMICONDUCTOR DETECTOR FOR RECORDING THE RAYLEIGH SCATTERING OF MOSSBAUER RADIATION
    Reklaitis, J.
    Baltrunas, D.
    Remeikis, V.
    Mazeika, K.
    [J]. LITHUANIAN JOURNAL OF PHYSICS, 2010, 50 (04): : 419 - 426
  • [32] CATHETER SEMICONDUCTOR RADIATION DETECTOR FOR CONTINUOUS MEASUREMENT OF CARDIAC OUTPUT
    UEDA, H
    SASAKI, Y
    IIO, M
    KAIHARA, S
    MACHIDA, K
    ITO, I
    TAKAYANA.SI
    KABAYASH.T
    SUGITA, T
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (12) : 713 - &
  • [33] Development of InSb Semiconductor Detector for High Resolution Radiation Measurement
    Park, Se-Hwan
    Kim, Han Soo
    Shin, Hee-Sung
    Kim, Ho-Dong
    Cho, Yun-Ho
    Kim, Yong Kyun
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (06) : 1577 - 1580
  • [34] A LOW-COST SEMICONDUCTOR RADIATION DETECTOR FOR PET RADIOCHEMISTRY
    RUTH, TJ
    ZEISLER, SK
    REKTOR, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 71 - NUCL
  • [35] PROCESSING AND INTERPRETATION OF DATA BY A SEMICONDUCTOR RADIATION NEEDLE-DETECTOR
    HETENYI, G
    DALZIEL, PD
    STUDNEY, DR
    HOWELL, WD
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1971, 22 (11): : 706 - &
  • [36] Fabrication and characteristics of a fully depleted semi-insulating GaAs semiconductor detector for alpha radiation detection at room temperature in air
    Ha, Jang Ho
    Kim, Yong Kyun
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 576 - 579
  • [37] FABRICATION OF RADIATION DETECTOR USING PBI2 CRYSTAL
    SHOJI, T
    OHBA, K
    SUEHIRO, T
    HIRATATE, Y
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 659 - 662
  • [38] Growth and fabrication method of CdTe and its performance as a radiation detector
    Choi, Hyojeong
    Jeong, Manhee
    Kim, Han Soo
    Kim, Young Soo
    Ha, Jang Ho
    Chai, Jong-Seo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (01) : 27 - 30
  • [39] Growth and fabrication method of CdTe and its performance as a radiation detector
    Hyojeong Choi
    Manhee Jeong
    Han Soo Kim
    Young Soo Kim
    Jang Ho Ha
    Jong-Seo Chai
    [J]. Journal of the Korean Physical Society, 2015, 66 : 27 - 30
  • [40] Growth and fabrication method of CdTe and its performance as a radiation detector
    Park S.
    Kim H.
    Kim D.