Correction of acidosis in hemodialysis decreases whole-body protein degradation

被引:0
|
作者
Graham, KA
Reaich, D
Channon, SM
Downie, S
Goodship, THJ
机构
[1] UNIV NEWCASTLE UPON TYNE, ROYAL VICTORIA INFIRM, DEPT MED, NEWCASTLE UPON TYNE NE1 4LP, TYNE & WEAR, ENGLAND
[2] UNIV DUNDEE, DEPT ANAT & PHYSIOL, DUNDEE, SCOTLAND
来源
关键词
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Correction of acidosis in hemodialysis (HD) decreases protein degradation. The effect of the correction of chronic metabolic acidosis in chronic renal failure patients treated with HD was determined from the kinetics of infused L-[1-C-13]leucine. Six HD patients were studied before (acid) and after (bicarbonate) correction of acidosis (pH: acid 7.36 +/- 0.01, bicarbonate 7.40 +/- 0.01, P < 0.005). Leucine appearance from body protein (PD) and leucine disappearance into body protein (PS) decreased significantly with correction of acidosis (PD: acid 180.6 +/- 7.3, bicarbonate 130.9 +/- 7.2 mu mol . kg(-1). h(-1), P < 0.005; PS: acid 172.3 +/- 6.8, bicarbonate 122.0 +/- 6.8 mu mol . kg(-1). h(-1), P < 0.005). There was no significant change in leucine oxidation or plasma amino acid concentrations. These results demonstrate that optimal correction of acidosis in HD is beneficial in terms of protein turnover and may improve long-term nutritional status in HD.
引用
收藏
页码:632 / 637
页数:6
相关论文
共 50 条
  • [31] INCREASED WHOLE-BODY PROTEIN BREAKDOWN PREDOMINATES OVER INCREASED WHOLE-BODY PROTEIN-SYNTHESIS IN MULTIPLE ORGAN FAILURE
    ARNOLD, J
    CAMPBELL, IT
    SAMUELS, TA
    DEVLIN, JC
    GREEN, CJ
    HIPKIN, LJ
    MACDONALD, IA
    SCRIMGEOUR, CM
    SMITH, K
    RENNIE, MJ
    CLINICAL SCIENCE, 1993, 84 (06) : 655 - 661
  • [32] Arterial stiffness acutely decreases after whole-body vibration in humans
    Otsuki, T.
    Takanami, Y.
    Aoi, W.
    Kawai, Y.
    Ichikawa, H.
    Yoshikawa, T.
    ACTA PHYSIOLOGICA, 2008, 194 (03) : 189 - 194
  • [33] WHOLE-BODY PROTEIN-TURNOVER IN ADULT HEMODIALYSIS-PATIENTS AS MEASURED BY STABLE ISOTOPE TECHNIQUES
    BERKELHAMMER, CH
    BAKER, JP
    JEEJEEBHOY, KN
    WHITTALL, R
    SLATER, A
    LEITER, LA
    ULDALL, PR
    WOLMAN, SL
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (04): : 840 - 840
  • [34] WHOLE-BODY PROTEIN-TURNOVER IN ADULT HEMODIALYSIS-PATIENTS AS MEASURED BY STABLE ISOTOPE TECHNIQUES
    BERKELHAMMER, CH
    BAKER, JP
    JEEJEEBHOY, KN
    WHITTALL, R
    SLATER, A
    LEITER, LA
    ULDALL, PR
    WOLMAN, SL
    CLINICAL RESEARCH, 1985, 33 (02): : A701 - A701
  • [35] WHOLE-BODY COUNTER WITH AN INVARIANT RESPONSE FOR WHOLE-BODY ANALYSIS
    MARISS, P
    JAHNS, E
    SCHOBER, O
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1978, 3 (02): : 129 - 135
  • [36] USE OF WHOLE-BODY SCINTILLATION CAMERA AS A WHOLE-BODY COUNTER
    LOTT, A
    SONNEMAK.R
    WILLIAMS, B
    TAUXE, WN
    SOUTHERN MEDICAL JOURNAL, 1973, 66 (11) : 1338 - 1338
  • [37] Joint Intensity Inhomogeneity Correction for Whole-Body MR Data
    Dzyubachyk, Oleh
    van der Geest, Rob J.
    Staring, Marius
    Boernert, Peter
    Reijnierse, Monique
    Bloem, Johan L.
    Lelieveldt, Boudewijn P. F.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I, 2013, 8149 : 106 - 113
  • [38] Adaptive, segmented attenuation correction for whole-body PET imaging
    Xu, M
    Cutler, PD
    Luk, WK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 331 - 336
  • [39] Correction factor for potassium-40 whole-body counting
    Japan Atom. Ener. Research Institute, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195, Japan
    不详
    J Nucl Sci Technol, 10 (952-956):
  • [40] Correction factor for potassium-40 whole-body counting
    Kinase, S
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1999, 36 (10) : 952 - 956