Mid-Term Clinical Results after Open Rotator Cuff Reconstruction in Double-Row Technique with Titanium Anchor Screws

被引:1
|
作者
Geyer, S. [1 ]
Schoch, C. [2 ]
Nelitz, M. [3 ]
Geyer, M. [2 ]
机构
[1] St Vinzenz Klin Pfronten, Orthopadie, D-87459 Pfronten, Germany
[2] St Vinzenz Klin Pfronten, Chirurg Orthopadie, D-87459 Pfronten, Germany
[3] MVZ Oberstdorf, Orthopadie Unfallchirurg, Oberstdorf, Germany
来源
关键词
open rotator cuff repair; double-row; costs; re-tear rate; SUTURE-BRIDGE TECHNIQUE; SUPRASPINATUS TENDON; SINGLE-ROW; REPAIR; INTEGRITY; OUTCOMES; TEARS;
D O I
10.1055/s-0035-1545966
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The double-row rotator cuff repair is discussed controversially. Despite improved biomechanical properties, reduced re-tear rates and higher costs, no significant difference compared to single-row fixation in the clinical results is found. Mid-term results of an open double-row fixation with titanium anchor screws are presented. Material and Methods: 237 patients (m=142, f=95, median age: 56.3 years) were operated in 2007 with this technique by the senior author (M.G.). Preoperatively, 2 years and 4,5 years postoperatively a subjective shoulder score (SSG) with follow-up rates of 86, 87 and 83%, was evaluated. 5.1 years postoperatively an objective evaluation of 131 patients using the Constant-Murley scores (CS), the simple shoulder tests (SST), Gerbers shoulder value and the evaluation with school grades followed. The integrity of the cuff was checked with ultrasound. The absolute (re-tears and partial re-tears) and the relative (re-tears, partial re-tears, thinning and thickening of the cuff) re-tear rates were evaluated. Results: In SSG a highly significant improvement from 51 to 83 points was found (p<0.001). In CS80 points (min.: 18; max.: 100), and in SST 11 points (min.: 2; max.: 12) were achieved. The shoulder value of Gerber increased significantly from preoperative 28.1 to 84.5% 5.1 years postoperative (p<0.001).The absolute re-tear rate, evaluated in ultrasound was 7.6%, the relative re-tear rate 17.6%. For primary rotator cuff reconstructions a higher CS with 82 points and a lower relative re-tear rate with 10.5% were found. The patients age had no significant influence on the clinical outcome. The rupture size showed a significant impact on the re-tear rate and the scores (p<0.05). Between the operated and healthy shoulder neither strength nor mobility were found to be significantly different. Men reached a highly significant better strength than women (p<0.001) which also resulted in a significantly better outcome in the CS (p<0.01). The costs for open titanium transfixation technique with 330Euro per case are markedly less than for arthroscopic suture bridge technique with 600 to 1000Euro per case. Conclusion: Open double-row cuff repair with titanium screws is a safe and cost effective technique with a low re-tear rate with comparable clinical results regarding open and arthroscopic procedures.
引用
收藏
页码:399 / 407
页数:9
相关论文
共 50 条
  • [21] Does the Literature Support Double-Row Suture Anchor Fixation for Arthroscopic Rotator Cuff Repair? A Systematic Review Comparing Double-Row and Single-Row Suture Anchor Configuration
    Nho, Shane J.
    Slabaugh, Mark A.
    Seroyer, Shane T.
    Grumet, Robert C.
    Wilson, Joseph B.
    Verma, Nikhil N.
    Romeo, Anthony A.
    Bach, Bernard R., Jr.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (11): : 1319 - 1328
  • [22] Long-term results after open rotator cuff reconstruction
    Kuehn, P.
    Koelbel, R.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2009, 4 (03): : 137 - 144
  • [23] Magnetic resonance appearance of bioabsorbable anchor screws for double row arthroscopic rotator cuff repairs
    Aditya C. Pawaskar
    Aashay Kekatpure
    Nam-Su Cho
    Yong-Girl Rhee
    In-Ho Jeon
    Indian Journal of Orthopaedics, 2015, 49 : 164 - 170
  • [24] Magnetic resonance appearance of bioabsorbable anchor screws for double row arthroscopic rotator cuff repairs
    Pawaskar, Aditya C.
    Kekatpure, Aashay
    Cho, Nam-Su
    Rhee, Yong-Girl
    Jeon, In-Ho
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 164 - 170
  • [25] Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique
    H. El-Azab
    S. Buchmann
    K. Beitzel
    S. Waldt
    Andreas B. Imhoff
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1730 - 1737
  • [26] Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique
    El-Azab, H.
    Buchmann, S.
    Beitzel, K.
    Waldt, S.
    Imhoff, Andreas B.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (12) : 1730 - 1737
  • [27] Functional Outcomes After Double-Row Versus Single-Row Rotator Cuff Repair
    Nicholas, Stephen J.
    Lee, Steven J.
    Mullaney, Michael J.
    Tyler, Timothy F.
    Fukunaga, Takumi
    Johnson, Christopher D.
    McHugh, Malachy P.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2016, 4 (10)
  • [28] A Novel Method to Determine Suture Anchor Loading After Rotator Cuff Repair A Study of Two Double-Row Techniques
    Khoury, Lisa D.
    Kwon, Young W.
    Kummer, Frederick J.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2010, 68 (01): : 25 - 28
  • [29] Arthroscopic double-row reconstruction of rotator cuff ruptures. Current state of the art
    Gerhardt, C.
    Scheibel, M.
    ARTHROSKOPIE, 2012, 25 (02) : 103 - 110
  • [30] Open double-row rotator cuff repair using the LASA-DR screw
    Schoch, C.
    Geyer, S.
    Geyer, M.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 78 - 89