Acrylonitrile-butadiene-styrene (ABS) composite electrode for the simultaneous determination of vitamins B2 and B6 in pharmaceutical samples

被引:24
|
作者
de Oliveira, Grasielli C. [1 ]
Pereira, Lucas C. [1 ]
Silva, Ana L. [1 ]
Semaan, Felipe S. [1 ]
Castilho, Marilza [2 ]
Ponzio, Eduardo A. [1 ]
机构
[1] Univ Fed Fluminense, Inst Quim, Grp Eletroquim & Eletroanalit GE, Campus Valonguinho, BR-24020141 Niteroi, RJ, Brazil
[2] Univ Fed Mato Grosso, Dept Quim, Grp Eletroanalit & Novos Mat GENMAT, BR-78060900 Cuiaba, MT, Brazil
关键词
Composite electrode; Graphite; ABS; Pyridoxine; Riboflavin; CARBON-PASTE ELECTRODE; WATER-SOLUBLE VITAMINS; THERMAL-DEGRADATION; VOLTAMMETRIC DETERMINATION; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL-BEHAVIOR; SELECTIVE DETERMINATION; PYRIDOXINE VITAMIN-B-6; RIBOFLAVIN; TERPOLYMER;
D O I
10.1007/s10008-018-3897-z
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A lab-made affordable composite electrode based on acrylonitrile-butadiene-styrene (ABS) and graphite was developed and applied for the simultaneous determination of vitamins B-2 (riboflavin, VB2) and B-6 (pyridoxine, VB6) in pharmaceutical samples. Different ABS-graphite composite electrodes (AGCE) were prepared in proportions ranging from 40 to 80% (graphite, m/m) and characterized by a many complimentary techniques such as thermogravimetry (TG), Raman spectroscopy, Fourier transform-infrared (FTIR), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Differential pulse voltammetry (DPV) was employed for analytical purposes, being several parameters investigated to determine the optimum experimental conditions. Best performance was obtained using as electrolyte 0.1 mol L-1 acetate buffer solution (pH 4.0), with a pulse amplitude of 100 mV, a scan increment of 5 mV, a modulation of time of 0.05 s, and a time interval of 0.5 s, resulting in a scanning rate of 10 mV s(-1). The use of a 70% AGCE electrode under optimized conditions provided as linear responses for VB2 and VB6 intervals from 0.25 to 1.2 mu mol L-1 (r = 0.997), and from 25 to 454 mu mol L-1 (r = 0.989), respectively, with limits of detection of 0.15 mu mol L-1 for VB2 and 10 mu mol L-1 for VB6. The AGCE presented satisfactory results for the simultaneous determination of VB2 and VB6 in commercially available tablets, with recoveries between 99.5 and 98.0%, being those statistically compatible to those found by a reference spectrophotometric procedure.
引用
收藏
页码:1607 / 1619
页数:13
相关论文
共 50 条
  • [1] Acrylonitrile-butadiene-styrene (ABS) composite electrode for the simultaneous determination of vitamins B2 and B6 in pharmaceutical samples
    Grasielli C. de Oliveira
    Lucas C. Pereira
    Ana L. Silva
    Felipe S. Semaan
    Marilza Castilho
    Eduardo A. Ponzio
    [J]. Journal of Solid State Electrochemistry, 2018, 22 : 1607 - 1619
  • [2] Simultaneous Voltammetric Determination of Cd2+ and Pb2+ in Gasoline Samples Employing a Chemically Modified Acrylonitrile-Butadiene-Styrene (ABS) Composite Electrode
    de Oliveira, Grasielli C.
    Vicentino, Priscila O.
    Cassella, Ricardo J.
    Xing, Yutao T.
    Ponzio, Eduardo A.
    [J]. ELECTROANALYSIS, 2021, 33 (03) : 682 - 694
  • [3] Multianalyte electrochemical electrode for the determination of vitamins B2 and B6 in complex biosystem
    Wang, Huimin
    Zhang, Xueli
    Wang, Shuangjue
    Xiao, Sa
    Ma, Hanyue
    Wang, Xia
    [J]. MICROCHEMICAL JOURNAL, 2020, 158
  • [4] Simultaneous Determination of Vitamins B1, B2 and B6 by Liquid Chromatography with MS Detection
    Bartoskova, Marie Pokorna
    Rysova, Jana
    Pinkrova, Jitka
    [J]. CHEMICKE LISTY, 2020, 114 (05): : 361 - 365
  • [5] A multicommuted fluorescence-based sensing system for simultaneous determination of Vitamins B2 and B6
    Llorent-Martínez, EJ
    García-Reyes, JF
    Ortega-Barrales, P
    Molina-Díaz, A
    [J]. ANALYTICA CHIMICA ACTA, 2006, 555 (01) : 128 - 133
  • [6] SIMULTANEOUS DETERMINATION OF VITAMINS B1, B2 AND B6 IN MULTIVITAMIN TABLET AND BIOLOGICAL FLUID BY RP-HPLC
    Soni, Himesh
    Singhai, A. K.
    Mishra, Kaushelendra
    Sharma, Sarvesh
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2012, 3 (07): : 2163 - 2167
  • [7] ERYTHROCYTE VITAMINS B1, B2 AND B6 AND ERYTHROPOIETIN
    MYDLIK, M
    DERZSIOVA, K
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 1993, 13 (06) : 464 - 466
  • [8] Simultaneous determination of vitamins B2, B6 and C using silver-doped poly(L-arginine)-modified glassy carbon electrode
    Liu, G.
    Wang, Y. M.
    Sun, D. M.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (01) : 102 - 109
  • [9] Simultaneous determination of vitamins B2, B6 and C using silver-doped poly(L-arginine)-modified glassy carbon electrode
    G. Liu
    Y. M. Wang
    D. M. Sun
    [J]. Journal of Analytical Chemistry, 2016, 71 : 102 - 109
  • [10] STABILIZATION OF VITAMINS IN PHARMACEUTICAL PREPARATIONS .5. VITAMINS B1, B2, B6 AND NIACINAMIDE IN ORAL LIQUID FORMULATIONS
    AGRAWAL, DK
    MOHANRAO, VK
    [J]. JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1962, D 21 (06): : 189 - &