Prevention of False-Positive Results: Development of an HPTLC Autographic Assay for the Detection of Natural Tyrosinase Inhibitors

被引:35
|
作者
Taibon, Judith [1 ]
Ankli, Anita [2 ]
Schwaiger, Stefan [1 ]
Magnenat, Camille
Boka, Vasilik-Ioanna [4 ]
Simoes-Pires, Claudia [3 ]
Aligiannis, Naktarios [4 ]
Cuendet, Muriel [3 ]
Skaltsounis, Alexios-Leandros [4 ]
Reich, Eike [2 ]
Stuppner, Hermann [1 ]
机构
[1] Univ Innsbruck, Inst Pharm Pharmacognosy, CMBI, CCB, A-6020 Innsbruck, Austria
[2] CAMAG Lab, Muttenz, Switzerland
[3] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[4] Univ Athens, Fac Pharm, Dept Pharmacognosy & Nat Prod Chem, Athens, Greece
关键词
autographic assay; HPTLC-MS; tyrosinase inhibitors; false positive results; AGENTS; SKIN;
D O I
10.1055/s-0035-1546250
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
A simple and rapid high-performance thin-layer chromatography-based autographic assay was established to screen plant extracts for the presence of tyrosinase-inhibiting substances. Three mobile phases were selected for the chromatographic separation of different types of extracts. After development, the plate was sprayed with the substrate solution Levodopa followed by a solution of the enzyme tyrosinase. Several known tyrosinase inhibitors were tested simultaneously as positive controls. They were detected as white spots with white light in remission from the plate as well as with white light transmitted through the plate. Some of the investigated extracts included spots showing a different behaviour; some lipophilic substances appeared as white spots in white light remission but were black in white light transmission. This behaviour, which could lead to false-positive results, was due to poor wettability of the corresponding spots. False-positive results were eliminated by adding Triton X-100 to the Levodopa solution and drying the plate after 10 minutes incubation with a molecular sieve. Tyrosinase inhibitors can be clearly identified as white spots against a dark background in white light remission as well as in white light transmitted through the plate. The established high-performance thin-layer chromatography autographic assay was validated and can be used as a standard method for the detection of tyrosinase inhibitors in plant extracts without causing false-positive results.
引用
收藏
页码:1198 / 1204
页数:7
相关论文
共 50 条
  • [41] False-positive results in premature infants with the Platelia® Aspergillus sandwich enzyme-linked immunosorbent assay
    Siemann, M
    Koch-Dörfler, M
    Gaude, M
    MYCOSES, 1998, 41 (9-10) : 373 - 377
  • [42] Enteral nutrition may cause false-positive results of Aspergillus Galactomannan assay in absence of gastrointestinal diseases
    Girmenia, Corrado
    Santilli, Stefania
    Ballaro, Daniele
    Del Giudice, Ilaria
    Armiento, Daniele
    Mauro, Francesca Romana
    MYCOSES, 2011, 54 (06) : E883 - E884
  • [43] The reconstructed skin micronucleus assay in EpiDerm™: Reduction of false-positive results - a mechanistic study with epigallocatechin gallate
    Yuki, Katsuyuki
    Ikeda, Naohiro
    Nishiyama, Naohiro
    Kasamatsu, Toshio
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2013, 757 (02) : 148 - 157
  • [44] FALSE-POSITIVE RESULTS IN THE RADIOIMMUNOASSAY DETECTION OF STILBENE DERIVATIVES AFTER ADMINISTRATION OF FLUORINATED CORTICOSTEROIDS TO ANIMALS
    BRUNN, H
    FISTER, P
    EIGENBRODT, E
    STOJANOWIC, V
    FOOD AND CHEMICAL TOXICOLOGY, 1985, 23 (10) : 931 - 935
  • [45] LEPROSY AS CAUSE OF FALSE-POSITIVE RESULTS IN SEROLOGICAL ASSAYS FOR THE DETECTION OF ANTIBODIES TO HIV-1
    ANDRADE, VL
    AVELLEIRA, JC
    MARQUES, A
    VIANNA, FR
    SCHECHTER, M
    INTERNATIONAL JOURNAL OF LEPROSY AND OTHER MYCOBACTERIAL DISEASES, 1991, 59 (01) : 125 - 126
  • [46] CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results
    Trilisky, Igor
    Dachman, Abraham H.
    Wroblewski, Kristen
    Vannier, Michael W.
    Horne, John M.
    RADIOGRAPHICS, 2014, 34 (07) : 1885 - 1905
  • [47] FALSE-POSITIVE RESULTS WITH EMIT(R)II AMPHETAMINE METHAMPHETAMINE ASSAY IN USERS OF COMMON PSYCHOTROPIC-DRUGS
    SMITHKIELLAND, A
    OLSEN, KM
    CHRISTOPHERSEN, AS
    CLINICAL CHEMISTRY, 1995, 41 (06) : 951 - 952
  • [48] Experimental evidence of false-positive Comet test results due to TiO2 particle - assay interactions
    Rajapakse, Katarina
    Drobne, Damjana
    Kastelec, Damijana
    Marinsek-Logar, Romana
    NANOTOXICOLOGY, 2013, 7 (05) : 1043 - 1051
  • [49] Cross-reactivity of SARS-CoV-2 with HIV chemiluminescent assay leading to false-positive results
    Tan, Shaun S.
    Chew, Ka Lip
    Saw, Sharon
    Jureen, Roland
    Sethi, Sunil
    JOURNAL OF CLINICAL PATHOLOGY, 2021, 74 (09) : 614 - 614