Prevention of False-Positive Results: Development of an HPTLC Autographic Assay for the Detection of Natural Tyrosinase Inhibitors

被引:35
|
作者
Taibon, Judith [1 ]
Ankli, Anita [2 ]
Schwaiger, Stefan [1 ]
Magnenat, Camille
Boka, Vasilik-Ioanna [4 ]
Simoes-Pires, Claudia [3 ]
Aligiannis, Naktarios [4 ]
Cuendet, Muriel [3 ]
Skaltsounis, Alexios-Leandros [4 ]
Reich, Eike [2 ]
Stuppner, Hermann [1 ]
机构
[1] Univ Innsbruck, Inst Pharm Pharmacognosy, CMBI, CCB, A-6020 Innsbruck, Austria
[2] CAMAG Lab, Muttenz, Switzerland
[3] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[4] Univ Athens, Fac Pharm, Dept Pharmacognosy & Nat Prod Chem, Athens, Greece
关键词
autographic assay; HPTLC-MS; tyrosinase inhibitors; false positive results; AGENTS; SKIN;
D O I
10.1055/s-0035-1546250
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
A simple and rapid high-performance thin-layer chromatography-based autographic assay was established to screen plant extracts for the presence of tyrosinase-inhibiting substances. Three mobile phases were selected for the chromatographic separation of different types of extracts. After development, the plate was sprayed with the substrate solution Levodopa followed by a solution of the enzyme tyrosinase. Several known tyrosinase inhibitors were tested simultaneously as positive controls. They were detected as white spots with white light in remission from the plate as well as with white light transmitted through the plate. Some of the investigated extracts included spots showing a different behaviour; some lipophilic substances appeared as white spots in white light remission but were black in white light transmission. This behaviour, which could lead to false-positive results, was due to poor wettability of the corresponding spots. False-positive results were eliminated by adding Triton X-100 to the Levodopa solution and drying the plate after 10 minutes incubation with a molecular sieve. Tyrosinase inhibitors can be clearly identified as white spots against a dark background in white light remission as well as in white light transmitted through the plate. The established high-performance thin-layer chromatography autographic assay was validated and can be used as a standard method for the detection of tyrosinase inhibitors in plant extracts without causing false-positive results.
引用
收藏
页码:1198 / 1204
页数:7
相关论文
共 50 条
  • [1] FALSE-POSITIVE RESULTS WITH MTT ASSAY
    ROLLINO, C
    BORSA, S
    BELLONE, G
    PICCOLI, G
    EMANUELLI, G
    JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 185 (01) : 141 - 143
  • [2] Development and validation of an HPTLC based assay for the screening and identification of tyrosinase inhibitors
    Taibon, J.
    Ankli, A.
    Magnenat, C.
    Simoes-Pires, C. A.
    Boka, V., I
    Argyropoulou, A.
    Aligiannis, N.
    Skaltsounis, A. L.
    Licea, Cuendet M.
    Stuppner, H.
    Reich, E.
    PLANTA MEDICA, 2014, 80 (16) : 1526 - 1526
  • [3] False-positive results of troponin assay with increased IgM antibodies
    Oddoze, C
    Boutib, A
    Desvignes, P
    Djiane, P
    Portugal, H
    ANNALES DE BIOLOGIE CLINIQUE, 2003, 61 (01) : 77 - 80
  • [4] Elimination of False-Positive Results in a Luminex Assay for Pneumococcal Antibodies
    Pickering, Jerry W.
    Larson, Matthew T.
    Martins, Thomas B.
    Copple, Susan S.
    Hill, Harry R.
    CLINICAL AND VACCINE IMMUNOLOGY, 2010, 17 (01) : 185 - 189
  • [5] False-positive acetaminophen results in hyperbilirubinemic patients with an enzymatic colorimetric assay
    Stolk, LM
    Nelissen, B
    van der Heijden, J
    PHARMACY WORLD & SCIENCE, 2003, 25 (05): : 242 - 242
  • [6] Analysis of the characteristics of patients with false-positive HIV screening assay results
    Lin, Yi-Qiang
    Gao, Ya-Ling
    Wang, Mao
    Yan, Shui-Di
    Lin, Li-Rong
    INTERNATIONAL IMMUNOPHARMACOLOGY, 2022, 105
  • [7] Proactive Prevention of False-positive Conflicts in Distributed Ontology Development
    Halilaj, Lavdim
    Grangel-Gonzalez, Irlan
    Vidal, Maria-Esther
    Lohmann, Steffen
    Auer, Soren
    KEOD: PROCEEDINGS OF THE 8TH INTERNATIONAL JOINT CONFERENCE ON KNOWLEDGE DISCOVERY, KNOWLEDGE ENGINEERING AND KNOWLEDGE MANAGEMENT - VOL. 2, 2016, : 43 - 51
  • [8] Serum albumin leads to false-positive results in the XTT and the MTT assay
    Funk, Dorothee
    Schrenk, Hans-Hermann
    Frei, Eva
    BIOTECHNIQUES, 2007, 43 (02) : 178 - +
  • [9] Carryover can be a cause of false-positive results with the Beckman AccuTnI assay
    Dimeski, Goce
    Jones, Brock
    Brown, Nigel
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (06) : 1135 - 1136
  • [10] False-positive Results of Quantiferon-Tb-Gold Assay in Children
    Quintana-Ortega, Cristian
    Mendez-Echevarria, Ana
    del Rosal, Teresa
    Gonzalez-Munoz, Miguel
    Baquero-Artigao, Fernando
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2020, 39 (07) : 620 - 623