Integration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean intra-abdominal pressure

被引:10
|
作者
Ahmadi-Noorbakhsh, Siavash [1 ]
Malbrain, Manu L. N. G. [2 ,3 ]
机构
[1] Saadat Abad Vet Specialty Clin, Tehran, Iran
[2] WSACS, Execut Comm, B-3360 Lovenjoel, Belgium
[3] Ziekenhuis Netwerk Antwerpen ZNA Stuivenberg, ICU & High Care Burn Unit, Dept Intens Care, B-2060 Antwerp, Belgium
来源
关键词
Tidal Volume; Abdominal Compartment Syndrome; Peep Level; Dynamic Compliance; Pulsion Medical System;
D O I
10.1186/2110-5820-2-S1-S18
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The intra-abdominal pressure (IAP) is an important clinical parameter that can significantly change during respiration. Currently, IAP is recorded at end-expiration (IAP(ee)), while continuous IAP changes during respiration (Delta IAP) are ignored. Herein, a novel concept of considering continuous IAP changes during respiration is presented. Methods: Based on the geometric mean of the IAP waveform (MIAP), a mathematical model was developed for calculating respiratory-integrated MIAP (i.e. MIAP(ri) = IAP(ee) + i . Delta IAP), where 'i' is the decimal fraction of the inspiratory time, and where Delta IAP can be calculated as the difference between the IAP at end-inspiration (IAP(ei)) minus IAP(ee). The effect of various parameters on IAP(ee) and MIAP(ri) was evaluated with a mathematical model and validated afterwards in six mechanically ventilated patients. The MIAP of the patients was also calculated using a CiMON monitor (Pulsion Medical Systems, Munich, Germany). Several other parameters were recorded and used for comparison. Results: The human study confirmed the mathematical modelling, showing that MIAP(ri) correlates well with MIAP (R-2 = 0.99); MIAP(ri) was significantly higher than IAP(ee) under all conditions that were used to examine the effects of changes in IAP(ee), the inspiratory/expiratory (I:E) ratio, and Delta IAP (P < 0.001). Univariate Pearson regression analysis showed significant correlations between MIAP(ri) and IAP(ei) (R = 0.99), IAP(ee) (R = 0.99), and.IAP (R = 0.78) (P < 0.001); multivariate regression analysis confirmed that IAP(ee) (mainly affected by the level of positive end-expiratory pressure, PEEP), Delta IAP, and the I:E ratio are independent variables (P < 0.001) determining MIAP. According to the results of a regression analysis, MIAP can also be calculated as MIAP = -0.3 + IAP(ee) + 0.4 . Delta IAP + 0.5 . I/E. Conclusions: We believe that the novel concept of MIAP is a better representation of IAP (especially in mechanically ventilated patients) because MIAP takes into account the IAP changes during respiration. The MIAP can be estimated by the MIAPri equation. Since MIAP(ri) is almost always greater than the classic IAP, this may have implications on end-organ function during intra-abdominal hypertension. Further clinical studies are necessary to evaluate the physiological effects of MIAP.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Abdominal perfusion pressure monitoring in intra-abdominal hypertension
    Cheatham, Michael L.
    ACTA CLINICA BELGICA, 2009, 64 (03) : 244 - 244
  • [42] EXTENDED MEASUREMENTS OF INTRA-ABDOMINAL PRESSURE DO NOT INCREASE THE DETECTION RATE OF INTRA-ABDOMINAL HYPERTENSION
    Blaser, A. Reintam
    Sarapuu, S.
    Tamme, K.
    Starkopf, J.
    INTENSIVE CARE MEDICINE, 2012, 38 : S168 - S168
  • [43] Epidural analgesia decreases intra-abdominal pressure in postoperative patients with primary intra-abdominal hypertension
    Hakobyan, R. V.
    Mkhoyan, G. G.
    ACTA CLINICA BELGICA, 2008, 63 (02) : 86 - 92
  • [44] Effects of ovariohysterectomy on intra-abdominal pressure and abdominal perfusion pressure in cats
    Bosch, L.
    Rivera del Alamo, M. M.
    Andaluz, A.
    Monreal, L.
    Torrente, C.
    Garcia-Arnas, F.
    Fresno, L.
    VETERINARY RECORD, 2012, 171 (24) : 622 - +
  • [45] The gold standard technique for intra-abdominal pressure monitoring in septic patients:: Continuous intra-abdominal pressure monitoring (CIAPM)
    Bodnar, Zsolt
    Sipka, Sandor
    Szentkereszty, Zoltan
    Hajdu, Zoltan
    Balogh, Zsolt
    INFLAMMATION RESEARCH, 2007, 56 : S213 - S214
  • [46] RECTAL PRESSURE MEASUREMENTS AND INTRA-ABDOMINAL PRESSURE CHANGES
    BARBALIAS, GA
    UROLOGY, 1983, 21 (03) : 331 - 331
  • [47] THE EFFECT OF POSITIVE END-EXPIRATORY PRESSURE (PEEP) ON INTRA-ABDOMINAL PRESSURE MEASUREMENTS
    De Keulenaer, B. L.
    De Waele, J. J.
    Malbrain, M. L. N. G.
    ACTA CLINICA BELGICA, 2009, 64 (03): : 254 - 254
  • [48] Positive end-expiratory pressure adjusted for intra-abdominal pressure - A pilot study
    Regli, Adrian
    De Keulenaer, Bart Leon
    Palermo, Annamaria
    van Heerden, Peter Vernon
    JOURNAL OF CRITICAL CARE, 2018, 43 : 390 - 394
  • [49] Intra-abdominal pressure and intra-abdominal hypertension in critically ill obstetric patients: a prospective cohort study
    Tyagi, A.
    Singh, S.
    Kumar, M.
    Sethi, A. K.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2017, 32 : 33 - 40
  • [50] Continuous intra-abdominal pressure measurement technique
    Balogh, Z
    Jones, F
    D'Amours, S
    Parr, M
    Sugrue, M
    AMERICAN JOURNAL OF SURGERY, 2004, 188 (06): : 679 - 683