Intercomparison of SO2 camera systems for imaging volcanic gas plumes

被引:37
|
作者
Kern, Christoph [1 ]
Luebcke, Peter [2 ]
Bobrowski, Nicole [2 ]
Campion, Robin [3 ]
Mori, Toshiya [4 ]
Smekens, Jean-Francois [5 ]
Stebel, Kerstin [6 ]
Tamburello, Giancarlo [7 ]
Burton, Mike [8 ]
Platt, Ulrich [2 ]
Prata, Fred [6 ]
机构
[1] USGS Cascades Volcano Observ, Vancouver, WA 98683 USA
[2] Heidelberg Univ, Inst Environm Phys, INF 229, D-69120 Heidelberg, Germany
[3] Univ Nacl Autonoma Mexico, Inst Geofis, Mexico City 04510, DF, Mexico
[4] Univ Tokyo, Grad Sch Sci, Bunkyo Ku, Tokyo 1130033, Japan
[5] Arizona State Univ, Sch Earth & Space Explorat, Tempe, AZ 85287 USA
[6] Norwegian Inst Air Res, Climate & Atmosphere Dept, N-2007 Metier, Norway
[7] Univ Palermo, Dipartimento Sci Terra & Mare, I-90123 Palermo, Italy
[8] Ist Nazl Geofis & Vulcanol, I-56122 Pisa, Italy
关键词
SO2; Camera; Volcanic gas emissions; Sulfur dioxide; Ultraviolet spectroscopy; Instrument intercomparison; Remote sensing; EMISSIONS;
D O I
10.1016/j.jvolgeores.2014.08.026
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
SO2 camera systems are increasingly being used to image volcanic gas plumes. The ability to derive SO2 emission rates directly from the acquired imagery at high time resolution allows volcanic process studies that incorporate other high time-resolution datasets. Though the general principles behind the SO2 camera have remained the same for a number of years, recent advances in CCD technology and an improved understanding of the physics behind the measurements have driven a continuous evolution of the camera systems. Here we present an intercomparison of seven different SO2 cameras. In the first part of the experiment, the various technical designs are compared and the advantages and drawbacks of individual design options are considered. Though the ideal design was found to be dependent on the specific application, a number of general recommendations are made. Next, a time series of images recorded by all instruments at Stromboli Volcano (Italy) is compared. All instruments were easily able to capture SO2 clouds emitted from the summit vents. Quantitative comparison of the SO2 load in an individual cloud yielded an intra-instrument precision of about 12%. From the imagery, emission rates were then derived according to each group's standard retrieval process. A daily average SO2 emission rate of 61 +/- 10 t/d was calculated. Due to differences in spatial integration methods and plume velocity determination, the time-dependent progression of SO2 emissions varied significantly among the individual systems. However, integration over distinct degassing events yielded comparable SO2 masses. Based on the intercomparison data, we find an approximate 1-sigma precision of 20% for the emission rates derived from the various SO2 cameras. Though it may still be improved in the future, this is currently within the typical accuracy of the measurement and is considered sufficient for most applications. Published by Elsevier B.V.
引用
收藏
页码:22 / 36
页数:15
相关论文
共 50 条
  • [41] Characterization and initial field test of an 8–14 μm thermal infrared hyperspectral imager for measuring SO2 in volcanic plumes
    Andrea Gabrieli
    Robert Wright
    Paul G. Lucey
    John N. Porter
    Harold Garbeil
    Eric Pilger
    Mark Wood
    Bulletin of Volcanology, 2016, 78
  • [42] Radioactive properties of SO2 gas
    Liu, Linhua
    Yan, Youcai
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 14 (04): : 293 - 295
  • [43] SO2 CONVERSION .3. REMOVING SO2 FROM FLUE GAS
    STITES, JG
    HORLACHE.WR
    BACHOFER, JL
    BARTMAN, JS
    CHEMICAL ENGINEERING PROGRESS, 1969, 65 (10) : 74 - &
  • [44] MEASUREMENT OF SO2 IN POWER-STATION PLUMES WITH DIFFERENTIAL LIDAR
    ADRAIN, RS
    BRASSINGTON, DJ
    SUTTON, S
    VAREY, RH
    OPTICAL AND QUANTUM ELECTRONICS, 1979, 11 (03) : 253 - 264
  • [45] Measurements of HONO, NO, NOy and SO2 in aircraft exhaust plumes at cruise
    Jurkat, T.
    Voigt, C.
    Arnold, F.
    Schlager, H.
    Kleffmann, J.
    Aufmhoff, H.
    Schaeuble, D.
    Schaefer, M.
    Schumann, U.
    GEOPHYSICAL RESEARCH LETTERS, 2011, 38
  • [46] Remote CO, COS, CO2, SO2, HCl detection and temperature estimation of volcanic gas
    Mori, T
    Notsu, K
    GEOPHYSICAL RESEARCH LETTERS, 1997, 24 (16) : 2047 - 2050
  • [47] Remote CO, COS, CO2, SO2, HCl detection and temperature estimation of volcanic gas
    Mori, Toshiya
    Notsu, Kenji
    Geophysical Research Letters, 1997, 24 (16): : 2047 - 2050
  • [48] UVolc: A software platform for measuring volcanic SO2 fluxes
    Kantzas, Euripides P.
    McGonigle, Andrew J. S.
    Tamburello, Giancarlo
    Bryant, Robert G.
    COMPUTERS & GEOSCIENCES, 2012, 40 : 194 - 199
  • [49] Modest volcanic SO2 emissions from the Indonesian archipelago
    Bani, Philipson
    Oppenheimer, Clive
    Tsanev, Vitchko
    Scaillet, Bruno
    Primulyana, Sofyan
    Saing, Ugan Boyson
    Alfianti, Hilma
    Marlia, Mita
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [50] A new permanent, low-cost, low-power SO2 camera for continuous measurement of volcanic emissions
    Wilkes, Thomas Charles
    Pering, Tom David
    Aguilera, Felipe
    Layana, Susana
    Nadeau, Patricia
    Kern, Christoph
    McGonigle, Andrew John Samuel
    Aguilera, Mauricio
    Zhu, Chengxi
    FRONTIERS IN EARTH SCIENCE, 2023, 11