Experimental characterization of monolithic-crystal small animal PET detectors read out by APD arrays

被引:61
|
作者
Maas, Marnix C. [1 ]
van der Laan, D. J.
Schaart, Dennis R.
Huizenga, Jan
Brouwer, J. C.
Bruyndonckx, Peter
Leonard, Sophie
Lemaitre, Cedric
van Eijk, Carel W. E.
机构
[1] Delft Univ Technol, NL-2629 JB Delft, Netherlands
[2] Vrije Univ Brussels, Inter Univ Inst High Energies, B-1050 Brussels, Belgium
关键词
angle of incidence; avalanche photodiode (APD); depth-of-interaction; monolithic scintillator crystals; nearest neighbor method; positron emission tomography (PET); spatial resolution;
D O I
10.1109/TNS.2006.873711
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Minimizing dead space is one way to increase the detection efficiency of small-animal PET scanners. By using monolithic scintillator crystals (e.g., 20 mm x 10 mm x 10 mm LSO), loss of efficiency due to inter-crystal reflective material is minimized. Readout of such crystals can be performed by means of one or more avalanche photo-diode (APD) arrays optically coupled to the crystal. The entry point of a gamma photon on the crystal surface can be estimated from the measured distribution of the scintillation light over the APD array(s). By estimating the entry point, correction for the depth-of-interaction (DOI) is automatically provided. We are studying the feasibility of such detector modules. To this end, a 64-channel test setup has been developed. Experiments to determine the effect on the spatial resolution of crystal surface finish and detector geometry have been carried out. The first results of these experiments are presented and compared to simulation results. The crystal surface finish has only a small influence on the spatial resolution. The spatial resolution of 20 mm x 10 nun x 10 mm detectors is significantly better when read out on the front side than when read out on the back side. With a 20 mm x 10 mm x 20 mm crystal coupled to two APD arrays, a very small resolution degradation of only similar to 0.2 min is observed for an incidence angle of 30 degrees compared to normal incidence.
引用
收藏
页码:1071 / 1077
页数:7
相关论文
共 30 条
  • [1] Performance of APD-based monolithic-crystal detectors for small animal PET
    Maas, Marnix C.
    van der Laan, D. J.
    Schaart, Dennis R.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    van Eijk, Carel W. E.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2017 - 2021
  • [2] Experimental characterization of novel small animal PET detector modules based on scintillation crystal blocks read out by APD arrays
    Maas, MC
    van der Laan, DJ
    Schaart, DR
    Huizenga, J
    Brouwer, JC
    Bruyndonckx, P
    Léonard, S
    Lemaître, C
    van Eijk, CWE
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2942 - 2946
  • [3] Limits on the spatial resolution of monolithic scintillators read out by APD arrays
    van der Laan, D. J.
    Maas, Marnix C.
    Bruyndonckx, Peter
    Schaart, Dennis R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6479 - 6496
  • [4] A cross-correlation method for crystal identification in APD-based phoswich detectors used in small animal PET scanner
    Semmaoui, Hicham
    Lecomte, Roger
    Fontaine, Rejean
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 597 (2-3): : 238 - 241
  • [5] Simulated performance of a small-animal PET scanner based on monolithic scintillation detectors
    van der Laan, D. J.
    Maas, M. C.
    de Jong, H. W. A. M.
    Schaart, D. R.
    Bruyndonckx, P.
    Lemaitre, C.
    van Eijk, C. W. E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 227 - 230
  • [6] Small animal PET prototype based on LSO crystals read out by avalanche photodiodes
    Fries, O.
    Bradbury, S.M.
    Gebauer, J.
    Holl, I.
    Lorenz, E.
    Renker, D.
    Ziegler, S.I.
    [J]. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 387 (1-2): : 220 - 224
  • [7] A small animal PET prototype based on LSO crystals read out by avalanche photodiodes
    Fries, O
    Bradbury, SM
    Gebauer, J
    Holl, I
    Lorenz, E
    Renker, D
    Ziegler, SI
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 387 (1-2): : 220 - 224
  • [8] Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules
    Braem, A.
    Chesi, E.
    Joram, C.
    Rudge, A.
    Seguinot, J.
    Weilhammer, P.
    De Leo, R.
    Nappi, E.
    Lustermann, W.
    Schinzel, D.
    Johnson, I.
    Renker, D.
    Albrecht, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 300 - 308
  • [9] Ultra-high-resolution depth-encoding small animal PET detectors: Using GAGG and LYSO crystal arrays
    Niu, Ming
    Liu, Zheng
    Kuang, Zhonghua
    Wang, Xiaohui
    Ren, Ning
    Sang, Ziru
    Wu, San
    Cong, Longhan
    Sun, Tao
    Hu, Zhanli
    Yang, Yongfeng
    [J]. MEDICAL PHYSICS, 2022, 49 (05) : 3006 - 3020
  • [10] Characterization of three layer depth of interaction PET detectors for small animal imaging
    Behnamian, H.
    Shafiee, M.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):