Performance of an energy resolving X-ray pixel detector

被引:7
|
作者
Bates, R
Derbyshire, G
Gannon, WJF
Iles, G
Lowe, B
Mathieson, K
Passmore, MS
Prydderch, M
Seller, P [1 ]
Smith, K
Thomas, SL
机构
[1] Rutherford Appleton Lab, Chilton OX11 0QX, England
[2] Univ Glasgow, Glasgow G12 8QQ, Lanark, Scotland
[3] Univ London Imperial Coll Sci Technol & Med, London SW7 2BZ, England
[4] Oxford Instruments, Abingdon, Oxon, England
关键词
pixels; spectroscopy; bump-bonding; noise; X-ray detector; X-ray; imaging;
D O I
10.1016/S0168-9002(01)01879-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have built a back-illuminated, silicon X-ray detector with 16 x 16 pixels. This is bump-bonded to an integrated circuit containing a corresponding array of pre-amplifiers. The bump-bonded unit is wire bonded to two 128 channel integrated circuits which have signal shaping, peak-hold and sparcification logic. These integrated circuits output the analogue value of the individual X-ray and the address of the 300 pm x 300 mum pixel. The system has previously demonstrated X-ray spectroscopy measurement in the 5-40 keV range with a resolution of I keV FWHM. This paper describes the performance of the system used in an X-ray diffraction experiment performed on the Daresbury Synchrotron Radiation Source. The second part demonstrates the successful operation of this pixellated detector for spectroscopy. In this part, the variation among the pixel outputs is accounted for without significantly affecting the noise performance. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
  • [41] Optimization of detector pixel size for interventional x-ray fluoroscopy
    Manjeshwar, RM
    Wilson, DL
    MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 : 23 - 34
  • [42] A CMOS Analog Integrated Circuit for Pixel X-ray Detector
    Fitrio, David
    Tjoa, Suhardi
    Mohan, Anand
    Veljanovski, Ronny
    Berry, Andrew
    PROCEEDINGS OF THE 2009 12TH INTERNATIONAL SYMPOSIUM ON INTEGRATED CIRCUITS (ISIC 2009), 2009, : 408 - +
  • [43] An X-ray imaging detector based on pixel structured scintillator
    Kim, Byoung-Jik
    Cho, Gyuseong
    Cha, Bo Kyung
    Kang, Bosun
    RADIATION MEASUREMENTS, 2007, 42 (08) : 1415 - 1418
  • [44] The gas pixel detector as a solar X-ray polarimeter and imager
    Fabiani, Sergio
    Costa, Enrico
    Bellazzini, Ronaldo
    Brez, Alessandro
    Di Cosimo, Sergio
    Lazzarotto, Francesco
    Muleri, Fabio
    Rubini, Alda
    Soffitta, Paolo
    Spandre, Gloria
    ADVANCES IN SPACE RESEARCH, 2012, 49 (01) : 143 - 149
  • [45] A hybrid pixel detector with two counters for X-ray Imaging
    Edling, F
    Brenner, R
    Bingefors, N
    Fransson, K
    Gustafsson, L
    Norrlid, LD
    Rönnqvist, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1422 - 1424
  • [46] Small pixel CZT detector for hard X-ray spectroscopy
    Wilson, Matthew David
    Cernik, Robert
    Chen, Henry
    Hansson, Conny
    Iniewski, Kris
    Jones, Lawrence L.
    Seller, Paul
    Veale, Matthew C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 158 - 161
  • [47] Assembly and test of the gas pixel detector for X-ray polarimetry
    Li, H.
    Feng, H.
    Muleri, E.
    Bellazzini, R.
    Minuti, M.
    Soffitta, P.
    Brez, A.
    Spandre, G.
    Pinchera, M.
    Sgro, C.
    Baldini, L.
    She, R.
    Costa, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 155 - 162
  • [48] Energy- and position-sensitive pixel detector Timepix for X-ray fluorescence imaging
    Zemlicka, Jan
    Jakubek, Jan
    Kroupa, Martin
    Tichy, Vladimir
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 202 - 204
  • [49] Development of a CdTe pixel detector with a window comparator ASIC for high energy X-ray applications
    Hirono, T.
    Toyokawa, H.
    Furukawa, Y.
    Honma, T.
    Ikeda, H.
    Kawase, M.
    Koganezawa, T.
    Ohata, T.
    Sato, M.
    Sato, G.
    Takagaki, M.
    Takahashi, T.
    Watanabe, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 88 - 91
  • [50] Energy-resolved X-ray imaging method with a counting-type pixel detector
    Toyokawa, H.
    Kajiwara, K.
    Sato, M.
    Kawase, M.
    Honma, T.
    Takagaki, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 84 - 87