Sub-diffraction imaging on standard microscopes through photobleaching microscopy with non-linear processing

被引:25
|
作者
Munck, Sebastian [1 ,2 ,3 ]
Miskiewicz, Katarzyna [1 ,2 ]
Sannerud, Ragna [1 ,2 ]
Menchon, Silvia A. [1 ,2 ]
Jose, Liya [1 ,2 ]
Heintzmann, Rainer [4 ,5 ,6 ]
Verstreken, Patrik [1 ,2 ]
Annaert, Wim [1 ,2 ]
机构
[1] VIB Ctr Biol Dis, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Ctr Human Genet, B-3000 Louvain, Belgium
[3] VIB, LiMoNe, B-3000 Louvain, Belgium
[4] Univ Jena, Inst Phys Chem, D-07743 Jena, Germany
[5] Inst Photon Technol, D-07745 Jena, Germany
[6] Kings Coll London, NHH, Randall Div Cell & Mol Biophys, London SE1 1UL, England
基金
欧洲研究理事会;
关键词
Bleaching; Super-resolution microscopy; Method; PiMP; SUBDIFFRACTION-RESOLUTION; ILLUMINATION MICROSCOPY; FLUORESCENCE MICROSCOPY; LIMIT; RECONSTRUCTION; DEPLETION; NANOSCOPY; BREAKING;
D O I
10.1242/jcs.098939
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Visualization of organelles and molecules at nanometer resolution is revolutionizing the biological sciences. However, such technology is still limited for many cell biologists. We present here a novel approach using photobleaching microscopy with non-linear processing (PiMP) for sub-diffraction imaging. Bleaching of fluorophores both within the single-molecule regime and beyond allows visualization of stochastic representations of sub-populations of fluorophores by imaging the same region over time. Our method is based on enhancing the probable positions of the fluorophores underlying the images. The random nature of the bleached fluorophores is assessed by calculating the deviation of the local actual bleached fluorescence intensity to the average bleach expectation as given by the overall decay of intensity. Subtracting measured from estimated decay images yields differential images. Non-linear enhancement of maxima in these diffraction-limited differential images approximates the positions of the underlying structure. Summing many such processed differential images yields a super-resolution PiMP image. PiMP allows multi-color, three-dimensional sub-diffraction imaging of cells and tissues using common fluorophores and can be implemented on standard wide-field or confocal systems.
引用
收藏
页码:2257 / 2266
页数:10
相关论文
共 50 条
  • [31] NON-LINEAR SIGNAL-PROCESSING FOR HIGH-RESOLUTION ACOUSTICAL IMAGING
    BORBURGH, J
    ERMERT, H
    ULTRASONIC IMAGING, 1980, 2 (02) : 191 - 191
  • [32] Imaging of Caenorhabditis elegans samples and sub-cellular localization of new generation photosensitizers for photodynamic therapy, using non-linear microscopy
    Filippidis, G
    Kouloumentas, C
    Kapsokalyvas, D
    Voglis, G
    Tavernarakis, N
    Papazoglou, TG
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2625 - 2632
  • [33] In vivo imaging of cellular structures and processes in Caenorhabditis elegans, using non-linear microscopy
    Filippidis, G.
    Gualda, E. J.
    Stefan, A.
    Mari, M.
    Fotakis, C.
    Voglis, G.
    Vlachos, M.
    Tavernarakis, N.
    2008 IEEE INTERNATIONAL WORKSHOP ON IMAGING SYSTEMS AND TECHNIQUES, 2008, : 64 - +
  • [34] Non-linear enhancement of ultrafast X-ray diffraction through transient resonances
    Kuschel, Stephan
    Ho, Phay J.
    Al Haddad, Andre
    Zimmermann, Felix F.
    Flueckiger, Leonie
    Ware, Matthew R.
    Duris, Joseph
    Macarthur, James P.
    Lutman, Alberto
    Lin, Ming-Fu
    Li, Xiang
    Nakahara, Kazutaka
    Aldrich, Jeff W.
    Walter, Peter
    Young, Linda
    Bostedt, Christoph
    Marinelli, Agostino
    Gorkhover, Tais
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [35] Non-linear stepped chirp waveforms with sub-pulse processing for range sidelobe suppression
    Keel, BM
    Saffold, JA
    Walbridge, MR
    Chadwick, J
    RADAR SENSOR TECHNOLOGY III, 1998, 3395 : 87 - 98
  • [36] Experimental investigation on through-wall imaging based on non-linear inversions
    Meng, Qingyang
    Ye, Dexin
    Huangfu, Jiangtao
    Li, Changzhi
    Ran, Lixin
    ELECTRONICS LETTERS, 2016, 52 (23)
  • [37] Substrate-mediated sub-diffraction guiding of optical signals through a linear chain of metal nanoparticles: Polarization dependence and the role of the dispersion relation
    Compaijen, P. J.
    Malyshev, V. A.
    Knoester, J.
    2013 7TH INTERNATIONAL CONGRESS ON ADVANCED ELECTROMAGNETIC MATERIALS IN MICROWAVES AND OPTICS (METAMATERIALS 2013), 2013, : 247 - 249
  • [38] Advanced multi-frequency GPR data processing for non-linear deterministic imaging
    Salucci, M.
    Poli, L.
    Massa, A.
    SIGNAL PROCESSING, 2017, 132 : 306 - 318
  • [39] Non-linear imaging and characterization of atherosclerotic arterial tissue using combined SHG and FLIM microscopy
    Cicchi, Riccardo
    Matthaeus, Christian
    Meyer, Tobias
    Lattermann, Annika
    Dietzek, Benjamin
    Brehm, Bernhard R.
    Popp, Juergen
    Pavone, Francesco S.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XV, 2015, 9329
  • [40] Effect of tissue fixation on the optical properties of structural components assessed by non-linear microscopy imaging
    Markus, M. Andrea
    Ferrari, Daniele P.
    Alves, Frauke
    Ramos-Gomes, Fernanda
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (08) : 3988 - 4002