A geometric view of signal sensitivity metrics in multi-echo fMRI

被引:1
|
作者
Liu, Thomas T. [1 ,2 ,3 ,4 ]
Li, Bochao [5 ]
Fernandez, Brice [6 ]
Banerjee, Suchandrima [7 ]
机构
[1] Univ Calif San Diego, Ctr Funct MRI, 9500 Gilman Dr MC 0677, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, 9500 Gilman Dr, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Psychiat, 9500 Gilman Dr, La Jolla, CA 92093 USA
[4] Univ Calif San Diego, Dept Bioengn, 9500 Gilman Dr, La Jolla, CA 92093 USA
[5] Univ Southern Calif, Dept Biomed Engn, Los Angeles, CA 90007 USA
[6] GE Healthcare, Buc, France
[7] GE Healthcare, Menlo Pk, CA USA
关键词
fMRI; Multi-echo; CNR; tSNR; BOLD-CONTRAST SENSITIVITY; PHYSIOLOGICAL NOISE; OPTIMIZATION; ENHANCEMENT; EPI; MRI;
D O I
10.1016/j.neuroimage.2022.119409
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In multi-echo fMRI (ME-fMRI), two metrics have been widely used to measure the performance of various acquisition and analysis approaches. These are temporal SNR (tSNR) and differential contrast-to-noise ratio (dCNR). A key step in ME-fMRI is the weighted combination of the data from multiple echoes, and prior work has examined the dependence of tSNR and dCNR on the choice of weights. However, most studies have focused on only one of these two metrics, and the relationship between the two metrics has not been examined. In this work, we present a geometric view that offers greater insight into the relation between the two metrics and their weight dependence. We identify three major regimes: (1) a tSNR robust regime in which tSNR is robust to the weight selection with most weight variants achieving close to optimal performance, whereas dCNR shows a pronounced dependence on the weights with most variants achieving suboptimal performance; (2) a dCNR robust regime in which dCNR is robust to the weight selection with most weight variants achieving close to optimal performance, while tSNR exhibits a strong dependence on the weights with most variants achieving significantly lower than optimal performance; and (3) a within-type robust regime in which both tSNR and dCNR achieve nearly optimal performance when the form of the weights are variants of their respective optimal weights and exhibit a moderate decrease in performance for other weight variants. Insight into the behavior observed in the different regimes is gained by considering spherical representations of the weight dependence of the components used to form each metric. For multi-echo acquisitions, dCNR is shown to be more directly related than tSNR to measures of CNR and signal-to-noise ratio (SNR) for task-based and resting-state fMRI scans, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Leveraging Multi-echo EPI to Improve Olfactory fMRI BOLD Sensitivity
    Zhao, Sichen Ludwig
    Raithel, Clara U.
    Tisdall, M. Dylan
    Detre, John A.
    Gottfried, Jay A.
    CHEMICAL SENSES, 2023, 48
  • [2] Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7 T
    Boyacioglu, Rasim
    Schulz, Jenni
    Koopmans, Peter J.
    Barth, Markus
    Norris, David G.
    NEUROIMAGE, 2015, 119 : 352 - 361
  • [3] An image registration strategy for multi-echo fMRI
    Jonsson, T
    Wennerberg, ABA
    Forssberg, H
    Glover, GH
    Li, TQ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (02): : 154 - 158
  • [4] Multivariate classification of complex and multi-echo fMRI data
    Peltier, Scott
    Noll, Douglas
    Lisinski, Jonathan
    LaConte, Stephen
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 229 - 232
  • [5] Theoretical optimization of multi-echo fMRI data acquisition
    Gowland, P. A.
    Bowtell, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07): : 1801 - 1813
  • [6] Multi-echo fMRI: A review of applications in fMRI denoising and analysis of BOLD signals
    Kundu, Prantik
    Voon, Valerie
    Balchandani, Priti
    Lombardo, Michael V.
    Poser, Benedikt A.
    Bandettini, Peter A.
    NEUROIMAGE, 2017, 154 : 59 - 80
  • [7] Multi-echo fMRI of the cortical laminae in humans at 7 T
    Koopmans, Peter J.
    Barth, Markus
    Orzada, Stephan
    Norris, David G.
    NEUROIMAGE, 2011, 56 (03) : 1276 - 1285
  • [8] Investigating the benefits of multi-echo EPI for fMRI at 7 T
    Poser, Benedikt A.
    Norris, David G.
    NEUROIMAGE, 2009, 45 (04) : 1162 - 1172
  • [9] Enhanced identification of BOLD-like components with multi-echo simultaneous multi-slice (MESMS) fMRI and multi-echo ICA
    Olafsson, Valur
    Kundu, Prantik
    Wong, Eric C.
    Bandettini, Peter A.
    Liu, Thomas T.
    NEUROIMAGE, 2015, 112 : 43 - 51
  • [10] Magnetization transfer weighted laminar fMRI with multi-echo FLASH
    Pfaffenrot, Viktor
    Koopmans, Peter J.
    NEUROIMAGE, 2022, 264