Quantification of the viability of residential air source heat pump water heaters as potential replacement for geysers in South Africa

被引:3
|
作者
Tangwe, Stephen Loh [1 ]
Simon, Michael [1 ]
机构
[1] Univ Ft Hare, Ft Hare Inst Technol, East London, South Africa
关键词
Load factor; Air source heat pump; Geyser; Global warming potential; Payback period;
D O I
10.1108/JEDT-05-2017-0042
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose This paper aims to compute demand, consumption and other avoidance saving by replacing existing geysers with split and integrated type air source heat pump (ASHP) water heaters, to prove the potential of both ASHP water heaters in both winter and summer by virtue of their coefficient of performance (COP) during the vapour compression refrigeration cycles and to demonstrate that despite the viability of both split and integrated ASHP system, the latter exhibits a better performance in terms of its COP and achievable savings and load factor. Design/methodology/approach This research emphasised the use of the data acquisition system housing various temperature sensors, power metres, flow metre, ambient temperature and relative humidity sensor to determine electrical energy consumption and useful thermal energy gained by the hot water in a geyser and storage tanks of residential ASHP water heaters. The load factors, average power and electrical energy consumptions for the 150 L high-pressure geyser, a 150 L split and integrated type ASHP water heaters were evaluated based on the controlled volume (150, 50 and 100 L) of daily hot water drawn off. Findings The results depicted that the average electrical energy consumed and load factors of the summer months for the geyser, split and integrated type ASHP water heaters were 312.3, 111.7 and 121.1 kWh and 17.9, 10.2 and 16.7 per cent, respectively. Finally, the simple payback period for both the split and integrated type ASHP water heaters were determined to be 3.9 and 5.2 years, respectively. By the application of the Eskom's projected tariff hikes over the years, the payback periods for the split and integrated ASHP water heaters could be reduced to 3.3 and 4.1 years, respectively. Originality/value The experimental design and methodology is the first of its kind to be conducted in South Africa. The results and interpretation were obtained from original data collected from the set of experiments conducted. Also, the authors are able to show that the introduction of back up element in an ASHP unit to run simultaneously with the vapour compression refrigeration cycles of the ASHP can reduce the COP of the overall system.
引用
收藏
页码:456 / 470
页数:15
相关论文
共 50 条
  • [41] AN EXPERIMENTAL ANALYSIS OF AIR SOURCE HEAT PUMP WATER HEATER
    Ozturk, M. Mete
    Erbay, L. Berrin
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 117 - 127
  • [42] Local Control of Heat Pump Water Heaters for Voltage Control with High Penetration of Residential PV Systems
    Mufaris, A. L. M.
    Baba, J.
    [J]. 2013 8TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2013, : 18 - +
  • [43] Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters
    Fenaughty, Karen
    Parker, Danny
    Butzbaugh, Joshua
    [J]. ASHRAE TRANSACTIONS 2022, VOL 128, PT 2, 2022, 128 : 659 - 667
  • [44] Evaluation of effect of providing power system balancing reserve from residential heat pump water heaters
    Omori, Hiroyuki
    Negishi, Shintaro
    Ikegami, Takashi
    [J]. IEEJ Transactions on Power and Energy, 2020, 140 (04) : 313 - 322
  • [45] Experimental and simulation study of air source heat pump for residential applications in northern China
    Yang, Yongan
    Li, Ruishen
    Zhu, Yiqun
    Sun, Zhili
    Zhang, Zhe
    [J]. ENERGY AND BUILDINGS, 2020, 224
  • [46] Potential energy optimisation in a domestic air to water heat pump
    Tangwe, Stephen
    Kusakana, Kanzumba
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2021, 36 (2-4) : 173 - 190
  • [47] Performance Investigation of An Air Source Heat Pump for Residential Heat Supply Through PCM Underfloor Heating
    Huang, Ming Jun
    Hewitt, Neil J.
    [J]. PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1763 - 1771
  • [48] Prevention of output suppression through heat pump water heaters for high-penetration residential PV systems
    Miyamoto, Yusuke
    Hayashi, Yasuhiro
    [J]. 2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 1715 - 1720
  • [49] Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs
    Sparn B.
    Maguire J.
    [J]. Current Sustainable/Renewable Energy Reports, 2021, 8 (02): : 107 - 113
  • [50] Exergy Analysis of Air-source Heat Pump Water Heater
    Mi Bingjie
    Luo Qinghai
    Chen Guojie
    [J]. PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 197 - 202