Selective photon counter for digital x-ray mammography tomosynthesis - art. no. 61425B

被引:0
|
作者
Goldan, Amir H. [1 ]
Karim, Karim S. [1 ]
Rowlands, J. A. [1 ]
机构
[1] Simon Fraser Univ, Burnaby, BC V5A 1S6, Canada
关键词
digital mammography; tomosynthesis; selective photon counter; pixel input-stage noise; complementary; folded cascode op amp; low noise; wide dynamic range; crystalline silicon technology;
D O I
10.1117/12.653764
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon counting is an emerging detection technique that is promising for mammography tomosynthesis imagers. In photon counting systems, the value of each image pixel is equal to the number of photons that interact with the detector. In this research, we introduce the design and implementation of a low noise, novel selective photon counting pixel for digital mammography tomosynthesis in crystalline silicon CMOS (complementary metal oxide semiconductor) 0.18 micron technology. The design comprises of a low noise charge amplifier (CA), two low offset voltage comparators, a decision-making unit (I)MU), a mode selector, and a pseudo-random counter. Theoretical calculations and simulation results of linearity, gain, and noise of the photon counting pixel are presented.
引用
下载
收藏
页码:B1425 / B1425
页数:9
相关论文
共 50 条
  • [1] Single photon counter for digital x-ray mammography tomosynthesis
    Goldan, AH
    Karim, KS
    Rowlands, JA
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2006, 24 (03): : 854 - 859
  • [2] Classification of breast masses and normal tissues in digital tomosynthesis mammography - art. no. 691508
    Wei, Jun
    Chan, Heang-Ping
    Zhang, Yiheng
    Sahiner, Berkman
    Zhou, Chuan
    Ge, Jun
    Wu, Yi-Ta
    Hadjiiski, Lubomir M.
    MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915 : 91508 - 91508
  • [3] Photon interference x-ray absorption fine structure -: art. no. 201101
    Nishino, Y
    Tröger, L
    Korecki, P
    Materlik, G
    PHYSICAL REVIEW B, 2001, 64 (20):
  • [4] Digital x-ray tomosynthesis: current state of the art and clinical potential
    Dobbins, JT
    Godfrey, DJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19): : R65 - R106
  • [5] Computer simulation for local x-ray diffractometry - art. no. 62530B
    Kalabushkin, Alexander Eu.
    Ninth International Workshop on Nondestructive Testing and Computer Simulations, 2006, 6253 : B2530 - B2530
  • [6] Polarimetry with a soft X-ray spectrometer - art. no. 701129
    Aarshall, Herman L.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011 : 1129 - 1129
  • [7] X-ray interferometry with microelectronvolt resolution -: art. no. 013904
    Shvyd'ko, YV
    Lerche, M
    Wille, HC
    Gerdau, E
    Lucht, M
    Rüter, HD
    Alp, EE
    Khachatryan, R
    PHYSICAL REVIEW LETTERS, 2003, 90 (01)
  • [8] Hard x-ray nanoprobe based on refractive x-ray lenses -: art. no. 124103
    Schroer, CG
    Kurapova, O
    Patommel, J
    Boye, P
    Feldkamp, J
    Lengeler, B
    Burghammer, M
    Riekel, C
    Vincze, L
    van der Hart, A
    Küchler, M
    APPLIED PHYSICS LETTERS, 2005, 87 (12) : 1 - 3
  • [9] Photon polarization in B→Xγ in the standard model -: art. no. 011504
    Grinstein, B
    Grossman, Y
    Ligeti, Z
    Pirjol, D
    PHYSICAL REVIEW D, 2005, 71 (01): : 011504 - 1
  • [10] Observation of heterodyne mixing in surface x-ray photon correlation spectroscopy experiments -: art. no. 076104
    Gutt, C
    Ghaderi, T
    Chamard, V
    Madsen, A
    Seydel, T
    Tolan, M
    Sprung, M
    Grübel, G
    Sinha, SK
    PHYSICAL REVIEW LETTERS, 2003, 91 (07)