Effect of flow patterns on bovine serum albumin and ampicillin partitioning using aqueous two-phase systems in microdevice

被引:15
|
作者
Pedro, Marcelo da Silva [1 ]
Fialho Oliveira, Luiz Andre [1 ]
de Araujo Padilha, Carlos Eduardo [1 ,2 ]
dos Santos, Everaldo Silvino [2 ]
de Oliveira, Jackson Araujo [1 ]
de Santana Souza, Domingos Fabiano [1 ]
机构
[1] Fed Univ Rio Grande do Norte UFRN, Chem Engn Dept, Lab Alternat Energy & Transport Phenomena, Natal, RN, Brazil
[2] Fed Univ Rio Grande do Norte UFRN, Chem Engn Dept, Lab Biochem Engn, Natal, RN, Brazil
关键词
Microfluid; Extraction; Polyethylene glycol; Bovine serum albumin; Droplet flow pattern; LIQUID-LIQUID FLOW; MASS-TRANSFER; POLY(ETHYLENE GLYCOL); SLUG FLOW; INTERFACIAL-TENSION; SOLVENT-EXTRACTION; SEPARATION; OPTIMIZATION; PHASE; MICROCHANNELS;
D O I
10.1016/j.seppur.2020.117592
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The separation and purification of biomolecules via aqueous two-phase extraction (ATPE) has encountered a series of obstacles to its industrial implementation. Recently, the miniaturization of ATPE has attracted interest due to the increase of performance, the possibility of operating in a continuous mode, and easy to scale-up by numbering-up approach. However, there is a gap in the literature with regard to the effects of flow patterns on the partitioning of biomolecules using microdevices. Thus, the present study investigated the ATPE of bovine serum albumin (BSA) and ampicillin, a beta-lactam antibiotic, under different flow patterns (slug, droplet and parallel) by means of microdevices. The microdevices were manufactured with circular tubes in a senoidal shape and the ATPE were prepared from the mixture between aqueous solutions of polyethylene glycol (PEG) and dibasic potassium phosphate. Using 1.80 mm tubes, slug, droplet and parallel flow patterns were observed only in the PEG 1500/dibasic potassium phosphate system, while the parallel flow pattern was not stabilized in systems involving PEG 4000 and PEG 6000. Experiments using a droplet flow pattern showed higher values of recovery (56% after 10 min) and partition coefficient of BSA compared to the slug and parallel flow patterns. In experiments involving ampicillin, the extraction performance was practically independent of the flow patterns. The BSA recovery behaved as an inverse function of the diameter tubes, which achieved slightly superior performance than the batch experiment (67% after 10 min) using droplet flow pattern, 0.51 mm tubes and residence time of 10 min (69%).
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Optimal Design of Aqueous Two-Phase Systems for Biomolecule Partitioning
    Chen, Yuqiu
    Liang, Xiaodong
    Kontogeorgis, Georgios M.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (28) : 11165 - 11177
  • [42] Partitioning of a Bacillus alkaline protease in aqueous two-phase systems
    Sinha, R
    Singh, SP
    Ahmed, S
    Garg, SK
    BIORESOURCE TECHNOLOGY, 1996, 55 (02) : 163 - 166
  • [43] Hybridoma and CHO cell partitioning in aqueous two-phase systems
    Zijlstra, GM
    Michielsen, MJF
    deGooijer, CD
    vanderPol, LA
    Tramper, J
    BIOTECHNOLOGY PROGRESS, 1996, 12 (03) : 363 - 370
  • [44] Affinity partitioning of human antibodies in aqueous two-phase systems
    Rosa, P. A. J.
    Azevedo, A. M.
    Ferreira, I. F.
    de Vries, J.
    Korporaal, R.
    Verhoef, H. J.
    Visser, T. J.
    Aires-Barros, M. R.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1162 (01) : 103 - 113
  • [45] Molecular features determining different partitioning patterns of papain and bromelain in aqueous two-phase systems
    Victoria Rocha, Maria
    Beatriz Nerli, Bibiana
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2013, 61 : 204 - 211
  • [46] Continuous cell partitioning using an aqueous two-phase flow system in microfluidic devices
    Yamada, M
    Kasim, V
    Nakashima, M
    Edahiro, J
    Seki, M
    BIOTECHNOLOGY AND BIOENGINEERING, 2004, 88 (04) : 489 - 494
  • [47] The effect of surface forces on flow patterns and flow characteristics in two-phase systems
    Brauner, N
    Maron, DM
    INTERNATIONAL SYMPOSIUM ON LIQUID-LIQUID TWO PHASE FLOW AND TRANSPORT PHENOMENA, 1998, : 21 - 40
  • [48] Aqueous two-phase extraction for bovine serum albumin (BSA) with co-laminar flow in a simple coaxial capillary microfluidic device
    Huang, Yushi
    Meng, Tao
    Guo, Ting
    Li, Wei
    Yan, Weili
    Li, Xueru
    Wang, Shu
    Tong, Zhiping
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (03) : 483 - 491
  • [49] Aqueous two-phase extraction for bovine serum albumin (BSA) with co-laminar flow in a simple coaxial capillary microfluidic device
    Yushi Huang
    Tao Meng
    Ting Guo
    Wei Li
    Weili Yan
    Xueru Li
    Shu Wang
    Zhiping Tong
    Microfluidics and Nanofluidics, 2014, 16 : 483 - 491
  • [50] Partitioning features of bovine trypsin and α-chymotrypsin in polyethyleneglycol- sodium citrate aqueous two-phase systems
    Tubio, Gisela
    Nerli, Bibiana
    Pico, Guillermo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 244 - 249