Exploiting sequential injection analysis technique to automate on-line sample treatment and quantitative determination of morphine in human urine

被引:38
|
作者
Idris, Abubakr M. [1 ]
Alnajjar, Ahmed O. [1 ]
机构
[1] King Faisal Univ, Dept Chem, Al Hufuf 31982, Saudi Arabia
关键词
Morphine; Sequential injection analysis; Forensic analysis; Clinical analysis;
D O I
10.1016/j.talanta.2008.04.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple uni-stream sequential injection analysis (SIA) manifold was developed to automate a method for the assay of morphine in human sample. The proposed SIA method includes on-line sample treatment, coupling reaction and spectrophotometric measurement. A rapid algorithm controlled the adopted procedure was critically programmed. For sample treatment, solid-phase extraction (SPE) was carried out into a homemade microcolumn, installed in the SIA manifold. Sufficient sample clean-Lip, extraction and preconcentration Were obtained by SPE. A coupling reaction of morphine with diazonium salt of aniline hydrochloride was adapted to SIA. The product of the reaction, an azo-morphine derivative, was spectrophotometrically detected at 390 nm. Parameters that influenced the efficiency of the proposed method, including Solution Volumes, diazonium Concentration, flow Fate and residence time, Were optimized. The proposed method was linear in a range of 0.10-2.5 mu g ml(-1). The limits of detection and quantification were 0.023 and 0.076 mu g ml(-1), respectively. The detectability of the method was enhanced by the preconcentration a rid the use of an extended path length (50 mm) of a flow cell. The method was validated by an H PLC method. Comparable results with respect to accuracy(recovery 96.3-97.1), repeatability (R.S.D. < 2.4%) and intermediate precision (R.S.D. < 3.1) were gained. The full-automation and miniaturization of the utilized technique offer rapidity, safety in handling urine sample and reagents as well as reduction of reagent and sample volumes. The method is Suitable for the application in forensic cases as an initial test and clinical analysis to prevent overdose-induced toxicity. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 50 条
  • [31] A new strategy for exploiting ion exchange in sequential injection analysis: In-line phytic acid separation/determination in foods as an example
    Sartini, RP
    Oliveira, CC
    ANALYTICAL SCIENCES, 2002, 18 (06) : 675 - 679
  • [32] Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration
    Cladera, A
    Miró, M
    Estela, JM
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2000, 421 (02) : 155 - 166
  • [33] Automatic On-Line Purge-and-Trap Sequential Injection Analysis for Trace Ammonium Determination in Untreated Estuarine and Seawater Samples
    Dimitriadou, Athina
    Anthemidis, Aristidis
    MOLECULES, 2020, 25 (07):
  • [34] Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine
    Piest'ansky, Juraj
    Marakova, Katarina
    Mikus, Peter
    MOLECULES, 2017, 22 (10)
  • [35] A fast and reliable method for the quantitative determination of benzimidazoles and metabolites in milk by LC-MS/MS with on-line sample treatment
    Garcia-Gomez, Diego
    Garcia-Hernandez, Marta
    Rodriguez-Gonzalo, Encarnacion
    Carabias-Martinez, Rita
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (10) : 2909 - 2914
  • [36] A fast and reliable method for the quantitative determination of benzimidazoles and metabolites in milk by LC-MS/MS with on-line sample treatment
    Diego García-Gómez
    Marta García-Hernández
    Encarnación Rodríguez-Gonzalo
    Rita Carabias-Martínez
    Analytical and Bioanalytical Chemistry, 2012, 404 : 2909 - 2914
  • [37] Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry
    Wang, JH
    Hansen, EH
    Gammelgaard, B
    TALANTA, 2001, 55 (01) : 117 - 126
  • [38] On-line sample preconcentration technique based on a dynamic pH junction in CE-amperometric detection for the analysis of biogenic amines in urine
    Tang, Wanrong
    Ge, Shuli
    Gao, Fan
    Wang, Guan
    Wang, Qingjiang
    He, Pingang
    Fang, Yuzhi
    ELECTROPHORESIS, 2013, 34 (14) : 2041 - 2048
  • [39] A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine
    Gallignani, M
    Bahsas, H
    Brunetto, MR
    Burguera, M
    Burguera, JL
    de Peña, YP
    ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) : 57 - 67
  • [40] Liquid chromatographic sample cleanup coupled on-line with gas chromatography in the analysis of beta-blockers in human serum and urine
    Hyotylainen, T
    Andersson, T
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (06) : 280 - 286