Initial experience with off-pump coronary artery bypass grafting

被引:4
|
作者
Kihara, S [1 ]
Shimakura, T [1 ]
Tanaka, SA [1 ]
Hanayama, N [1 ]
Saito, N [1 ]
Sugawara, Y [1 ]
Hirasawa, Y [1 ]
Maeba, S [1 ]
机构
[1] Fukuyama Cardiovasc Hosp, Dept Cardiovasc Surg, Hiroshima 7200809, Japan
关键词
off-pump coronary artery bypass grafting; minimally invasive coronary artery bypass grafting;
D O I
10.1007/s003800170002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Off-pump coronary artery bypass grafting (OPCAB) is clearly preferable for patients with extracardiac complications. The aim of this study was to evaluate the initial outcome of OPCAB, and its validity for patients with extracardiac complications. One hundred and fifty-seven consecutive coronary artery bypass graft (CABG) patients were divided into two groups: 30 OPCAB patients and 127 on-pump CABG patients. The early outcomes of the two groups were compared. Preoperatively, OPCAB patients had more extracardiac risk factors than on-pump CABG patients. There were no differences in age or cardiac function between the groups, but the off-pump group had a higher incidence of previous surgery, cerebrovascular disease, and renal failure. There were no differences in graft patency, stroke, or mortality between the two groups, even though the OPCAB patients had more risk factors than the on-pump patients. Our initial experience with OPCAB showed that it is acceptable for high-risk patients in view of the serious nature of their extracardiac condition.
引用
收藏
页码:9 / 11
页数:3
相关论文
共 50 条
  • [41] Outcomes of off-pump coronary artery bypass grafting in females
    Guzman-Gonzalez, Ricardo
    Careaga-Reyna, Guillermo
    Cardoza-Pacheco, Hugo
    Argueero-Sanchez, Ruben
    CIRUGIA Y CIRUJANOS, 2008, 76 (01): : 29 - 35
  • [42] Why is "off-pump" coronary artery bypass grafting better?
    Buffolo, E
    HEART SURGERY FORUM, 2002, 5 (02): : 154 - 156
  • [43] Surgical Considerations in Off-Pump Coronary Artery Bypass Grafting
    Reddy, Ramachandra C.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2011, 23 (01) : 14 - 17
  • [44] Safety and efficacy of off-pump coronary artery bypass grafting
    Arom, KV
    Flavin, TF
    Emery, RW
    Kshettry, VR
    Janey, PA
    Petersen, RJ
    ANNALS OF THORACIC SURGERY, 2000, 69 (03): : 704 - 710
  • [45] Off-pump coronary artery bypass grafting: Not a flash in the pan
    Ascione, R
    Caputo, M
    Angelini, GD
    ANNALS OF THORACIC SURGERY, 2003, 75 (01): : 306 - 313
  • [46] Anaesthesia for off-pump coronary artery bypass grafting surgery
    Alston, R. Peter
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2015, 16 (10): : 524 - 527
  • [47] Anaesthesia for off-pump coronary artery bypass grafting surgery
    Alston, R. Peter
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2012, 13 (10): : 510 - 512
  • [48] Off-pump coronary artery bypass grafting in a tracheostomy patient
    Kasai, Mio
    Osako, Motohiko
    Yamada, Toshiyuki
    Yamabe, Kentaro
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2019, 67 (09) : 803 - 805
  • [49] Off-pump coronary artery bypass grafting in Moyamoya disease
    Kim, Do-Kyun
    Yoo, Kyung-Jong
    YONSEI MEDICAL JOURNAL, 2007, 48 (05) : 876 - 878
  • [50] Off-Pump Coronary Artery Bypass Grafting; is it Still Relevant?
    Ofoegbu, Chima K. P.
    Manganyi, Rodgers M.
    CURRENT CARDIOLOGY REVIEWS, 2022, 18 (02) : 64 - 77