Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries

被引:56
|
作者
Achenbach, Stephan [1 ,2 ,3 ,4 ]
Manolopoulos, Michael [3 ,4 ]
Schuhbaeck, Annika [1 ,2 ]
Ropers, Dieter [3 ,4 ]
Rixe, Johannes [1 ,2 ]
Schneider, Christian [1 ,2 ]
Krombach, Gabriele A. [1 ,2 ]
Uder, Michael [3 ,4 ]
Hamm, Christian [1 ,2 ]
Daniel, Werner G. [3 ,4 ]
Lell, Michael [3 ,4 ]
机构
[1] Univ Giessen, Dept Cardiol, D-35392 Giessen, Germany
[2] Univ Giessen, Dept Radiol, D-35392 Giessen, Germany
[3] Univ Erlangen Nurnberg, Dept Radiol, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Cardiol, Erlangen, Germany
关键词
Coronary CT angiography; Image quality; Heart rate; Dual-source CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; RECONSTRUCTION INTERVALS; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; WINDOWS;
D O I
10.1016/j.jcct.2011.11.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Coronary CT angiography allows visualization of the coronary arteries. However, motion artifact can impair delineation of the coronary artery lumen and detection of coronary artery stenoses. OBJECTIVE: We investigated the influence of heart rate and the segment of the cardiac cycle during which images are reconstructed on the occurrence of motion artifacts. METHODS: We evaluated coronary CT angiography datasets obtained by 64-slice dual-source CT in 100 consecutive patients. Data were reconstructed at 13 time instants during the cardiac cycle and evaluated for the presence of motion artifact. RESULTS: Mean heart rate was 66 +/- 14 beats/min. Overall, 98 of 100 patients had evaluable datasets. For heart rates <= 60 beats/min, optimal image quality was uniformly found during late diastole (100% of cases with evaluable image quality during a time window between 65% and 75% of the cardiac cycle). With increasing heart rates, images reconstructed during late systole more frequently provided best image quality. However, image reconstruction could not be restricted to a systolic time period. To achieve evaluable image quality in 95% of cases, data acquired between 25% and 75% of the cardiac cycle had to be available for patients with heart rates >60 beats/min. CONCLUSION: Dual-source CT provides high image quality across a wide range of heart rates. Although data acquisition may be limited to diastole for patients with heart rates <= 60 beats/min, the availability of data acquired both during systole and diastole is necessary for patients with higher heart rates. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [21] Y Reduction of cardiac motion artifact in step-and-shoot coronary CT angiography with third-generation as compared with second-generation dual-source CT scanners
    Jin, Liang
    Zhou, Ji'an
    Gao, Yiyi
    Zhao, Wei
    Li, Ming
    Wang, Zhizhong
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (04) : 482 - 487
  • [22] Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    Tamci, Batuhan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 56 - 63
  • [23] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [24] Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease
    Meng, Lingdong
    Cui, Lianqun
    Cheng, Yuntao
    Wu, Xiaoyan
    Tang, Yuansheng
    Wang, Yong
    Xu, Fayun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 347 - 354
  • [25] Is dual-source CT coronary angiography ready for the real world?
    Cademartiri, Filippo
    Maffei, Erica
    Mollet, Nico R.
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 701 - 703
  • [26] Electrocardiographically triggered CT angiography of the whole aorta and coronary arteries with high-pitch dual-source CT
    张楠
    China Medical Abstracts (Internal Medicine), 2013, 30 (02) : 65 - 65
  • [27] Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
    Alkadhi, Hatem
    Scheffel, Hans
    Desbiolles, Lotus
    Gaemperli, Oliver
    Stolzmann, Paul
    Plass, Andre
    Goerres, Gerhard W.
    Luescher, Thomas F.
    Genoni, Michele
    Marincek, Borut
    Kaufmann, Philipp A.
    Leschka, Sebastian
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 766 - 776
  • [28] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [29] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [30] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Sun, Ming-li
    Lu, Bin
    Wu, Run-ze
    Johnson, Laura
    Han, Lei
    Liu, Gang
    Yu, Fang-Fang
    Hou, Zhi-hui
    Gao, Yang
    Wang, Hong-yu
    Jiang, Shiliang
    Yang, Yue-jin
    Qiao, Shu-bin
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1635 - 1642