Modelling the IEC 61850 and DNP3 Protocol Using OPNET in an Electrical Substation Communication Network

被引:0
|
作者
Njova, Dion [1 ]
Ogudo, Kingsley [2 ]
Umenne, Patrice [1 ]
机构
[1] Univ South Africa, Dept Elect & Min Engn, Johannesburg, South Africa
[2] Univ Johannesburg, Dept Elect & Elect Engn, Fac Engn & Built Environm, Johannesburg, South Africa
关键词
Supervisory Control and Data Acquisition (SCADA); Distributed Network Protocol (DNP3); International Electrotechnical Commission (IEC) 61850; Intelligent Electronic Devices (LED's); Remote Terminal Unit (RTU);
D O I
10.1109/icABCD54961.2022.9856151
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Communication protocols are a composite of supervisory control and data acquisition (SCADA) and they are used by the devices connected on the SCADA network. In this paper the distributed network protocol (DNP3) and International Electrotechnical Commission IEC 61850 communication protocols were modelled in OPNET. The simulation of DNP3 and MC 61850 communication protocol is done in different scenarios and the traffic behavior is analyzed. The DNP3 protocol is modelled as the medium protocol of communication during the maintenance of a 400kV Transformer at an Electrical Substation. Its network traffic behavior is then analyzed for this operation. The IEC 61850 protocol is then used as a medium of communication in the same Electrical Substation communication network (SCN) when a faulty backbone switch is present. In this scenario the network traffic behavior is again analyzed. The DNP3 simulation during the maintenance of the 400 kV Transformer shows that the model is working since the throughput is consistent without dropped packets at the Substation RTU end and the 400kV Transformer IED end. The IEC 61850 simulation when a faulty backbone switch is present shows that the model is working in this scenario since the throughput is again consistent. When the IEC 61850 protocol is modelled on the SCN, the time delay is 80 Its during normal operation and with a faulty switch the delay is 100 Its for this protocol. This shows that for the IEC 61850 model the time delay increases when there is a faulty backbone switch but not exceedingly since there is a backup switch in the structure. In the DNP3 model during the maintenance of the 400kV Transformer the time delay is approximately 160 Its. The IEC 61850 protocol performs approximately twice as fast as the DNP3 protocol during normal operation in an SCN.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Study on relaying protection communication network in digital substation using OPNET simulation
    Fang, Xiao-Jie
    Ji, Xia-Yi
    Lu, Zhi-Gang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (23): : 137 - 140
  • [22] Real-Time Analysis of Time-Critical Messages in IEC 61850 Electrical Substation Communication Systems
    Leon, Hector
    Montez, Carlos
    Valle, Odilson
    Vasques, Francisco
    ENERGIES, 2019, 12 (12)
  • [23] Multi-state IEC-61850 Substation Communication Network based on Markov partitions and symbolic dynamics
    Mathebula, Vonani Clive
    Saha, Akshay Kumar
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2021, 26
  • [24] Process-to-Bay Level Peer-to-Peer Network Delay in IEC 61850 Substation Communication Systems
    Das, Narottam
    Aung, Tin Tun
    Islam, Syed
    2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [25] Reliability of IEC 61850 based substation communication network architecture considering quality of repairs and common cause failures
    Vonani Clive Mathebula
    Akshay Kumar Saha
    Protection and Control of Modern Power Systems, 2022, 7
  • [26] Reliability of IEC 61850 based substation communication network architecture considering quality of repairs and common cause failures
    Mathebula, Vonani Clive
    Saha, Akshay Kumar
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)
  • [27] If I Knew Then What I Know Now: On Reevaluating DNP3 Security using Power Substation Traffic
    Irvene, Celine
    Shekari, Tohid
    Formby, David
    Beyah, Raheem
    5TH ANNUAL INDUSTRIAL CONTROL SYSTEM SECURITY WORKSHOP (ICSS 2019), 2019, : 48 - 59
  • [28] Communication Protocol Conversion on Electrical Equipment Intelligent Monitoring System Based on IEC61850 Standard
    Wang, Yongqiang
    Zhao, Yilei
    Yue, Yun
    2012 INTERNATIONAL CONFERENCE ON FUTURE COMMUNICATION AND COMPUTER TECHNOLOGY (ICFCCT 2012), 2012, : 42 - 46
  • [29] Responsiveness of Multi-Channel IEC-61850 Substation Communication Network Reliability Performance to Changes in Repair Factors
    Mathebula, Vonani Clive
    Saha, Akshay Kumar
    IEEE ACCESS, 2021, 9 : 789 - 800
  • [30] De-Synchronisation Attack Modelling in Real-Time Protocols Using Queue Networks: Attacking the ISO/IEC 61850 Substation Automation Protocol
    Wright, James G.
    Wolthusen, Stephen D.
    CRITICAL INFORMATION INFRASTRUCTURES SECURITY (CRITIS 2017), 2018, 10707 : 131 - 143