Modelling the IEC 61850 and DNP3 Protocol Using OPNET in an Electrical Substation Communication Network

被引:0
|
作者
Njova, Dion [1 ]
Ogudo, Kingsley [2 ]
Umenne, Patrice [1 ]
机构
[1] Univ South Africa, Dept Elect & Min Engn, Johannesburg, South Africa
[2] Univ Johannesburg, Dept Elect & Elect Engn, Fac Engn & Built Environm, Johannesburg, South Africa
关键词
Supervisory Control and Data Acquisition (SCADA); Distributed Network Protocol (DNP3); International Electrotechnical Commission (IEC) 61850; Intelligent Electronic Devices (LED's); Remote Terminal Unit (RTU);
D O I
10.1109/icABCD54961.2022.9856151
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Communication protocols are a composite of supervisory control and data acquisition (SCADA) and they are used by the devices connected on the SCADA network. In this paper the distributed network protocol (DNP3) and International Electrotechnical Commission IEC 61850 communication protocols were modelled in OPNET. The simulation of DNP3 and MC 61850 communication protocol is done in different scenarios and the traffic behavior is analyzed. The DNP3 protocol is modelled as the medium protocol of communication during the maintenance of a 400kV Transformer at an Electrical Substation. Its network traffic behavior is then analyzed for this operation. The IEC 61850 protocol is then used as a medium of communication in the same Electrical Substation communication network (SCN) when a faulty backbone switch is present. In this scenario the network traffic behavior is again analyzed. The DNP3 simulation during the maintenance of the 400 kV Transformer shows that the model is working since the throughput is consistent without dropped packets at the Substation RTU end and the 400kV Transformer IED end. The IEC 61850 simulation when a faulty backbone switch is present shows that the model is working in this scenario since the throughput is again consistent. When the IEC 61850 protocol is modelled on the SCN, the time delay is 80 Its during normal operation and with a faulty switch the delay is 100 Its for this protocol. This shows that for the IEC 61850 model the time delay increases when there is a faulty backbone switch but not exceedingly since there is a backup switch in the structure. In the DNP3 model during the maintenance of the 400kV Transformer the time delay is approximately 160 Its. The IEC 61850 protocol performs approximately twice as fast as the DNP3 protocol during normal operation in an SCN.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Packet Analysis of DNP3 protocol over TCP/IP at an Electrical Substation Grid modelled in OPNET.
    Njova, Dion
    Ogudo, Kingsley
    Umenne, Patrice
    2020 IEEE PES & IAS POWERAFRICA CONFERENCE, 2020,
  • [2] Sensor Based Communication Network for WACS with DNP3
    Neeraja, T. P.
    Pa, Sivraj
    Sasi, K. K.
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 76 - 81
  • [3] Benchmarking of performance requirements between IEC 61850 and DNP3 in Real-time Monitoring context
    Villalta, Vinicius de O.
    Netto, Roberto S.
    Caetano, Ricardo E.
    Bonatto, Benedito D.
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [4] Trust System Architecture for Securing GOOSE Communication in IEC 61850 Substation Network
    Rashid, Muhammad Talha Abdul
    Yussof, Salman
    Yusoff, Yunus
    INTERNATIONAL JOURNAL OF SECURITY AND ITS APPLICATIONS, 2016, 10 (04): : 289 - 302
  • [5] Performance analysis and simulation of communication network in substation based on IEC61850
    Chang, H
    Huang, WH
    Ru, F
    Huang, W
    Xue, JY
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7972 - 7974
  • [6] Seamless communication network of substation automation system based on the IEC61850
    Chang, H
    Ru, F
    Huang, W
    Xue, JY
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7975 - 7978
  • [7] Design and Performance of a Split Protocol Architecture on Distributed Network Protocol 3 (DNP3)
    Richard, Anand
    Appiah-Kubi, Patrick
    2017 IEEE INTERNATIONAL CONFERENCE ON ELECTRO INFORMATION TECHNOLOGY (EIT), 2017, : 249 - 253
  • [8] Modelling and simulation for performance evaluation of IEC61850-Based substation communication systems
    Sidhu, Tarlochan S.
    Yin, Yujie
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) : 1482 - 1489
  • [9] A Network Protection Framework for DNP3 Over TCP/IP Protocol
    Bai, Jin
    Hariri, Salim
    Al-Nashif, Youssif
    2014 IEEE/ACS 11TH INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS AND APPLICATIONS (AICCSA), 2014, : 9 - 15
  • [10] Modeling of IEC 61850 GOOSE Substation Communication Traffic Using ARMA Model
    Feizimirkhani, Ronak
    Bratcu, Antoneta Iuliana
    Besanger, Yvon
    Labonne, Antoine
    Braconnier, Thierry
    PROCEEDINGS OF 2019 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE), 2019,