Rapid and fully-automated detection of Clostridium difficile Toxin B via magnetic-particle-based chemiluminescent immunoassay

被引:1
|
作者
Qi, Haonan [1 ]
Wang, Yu [2 ]
Wu, Peidian [3 ]
Ma, Yi [1 ]
Wang, Jufang [1 ]
机构
[1] South China Univ Technol, Sch Biol & Biol Engn, Guangzhou 510006, Peoples R China
[2] South China Univ Technol, Coll Food Sci, Guangzhou 510006, Peoples R China
[3] Guangzhou Wondfo Biotech Co Ltd, Natl & Local United Engn Lab Rapid Diagnost Test, Guangzhou 510663, Peoples R China
来源
关键词
Toxin B; high-affinity antibodies; automation; chemiluminescent immunoassay; point-of-care tests; clinical application; ENZYME-IMMUNOASSAY; INFECTION; DIAGNOSIS; ASSAY; PERFORMANCE;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Clostridium difficile colitis is caused by a cytotoxin produced by the anaerobic bacteria C. difficile on the epithelial cells of the large intestine, particularly C. difficile toxin B (Tcd B). Current C. difficile toxin assays have proven to be insensitive and have thus been ruled out from diagnostic purposes. Therefore, Tcd B detection via sandwich-type chemiluminescent immunoassay was proposed as a straightforward approach with potential diagnostic applicability. Here, two high-affinity anti Tcd B monoclonal antibodies were successfully identified and implemented in a fully-automated magnetic-particle-based chemiluminescent immunoassay (CLEIA). In this test, toxin B was sandwiched between the anti-toxin B antibody-coated magnetic particles and alkaline phosphate-labeled antitoxin B antibodies. Compared with traditional techniques, the proposed immunoassay demonstrated high sensitivity for toxin B identification and was further optimized to achieve a linear response ranging from 0.12 to 150 ng/mL with a limit of detection (LOD) of 0.47 ng/mL. Importantly, the entire process could be completed in less than 30 minutes. The proposed assay was used to detect toxin B in 104 randomly-selected human stool samples and delivered similar results to those of a commercial EUSA kit, highlighting its great potential for rapid and efficient toxin B determination in human stool specimens.
引用
收藏
页码:4228 / 4236
页数:9
相关论文
共 37 条
  • [31] Rapid Quantitative Detection of Salmonella spp. via Magnetic Beads-based Fluorescent Lateral Flow Immunoassay
    Zhuang, Linlin
    Gong, Jiansen
    Ji, Yongxin
    Gu, Ning
    Zhang, Yu
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO 2019), 2019, : 80 - 85
  • [32] A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screening
    Alefantis, T
    Grewal, P
    Ashton, J
    Khan, AS
    Valdes, JJ
    Del Vecchio, VG
    MOLECULAR AND CELLULAR PROBES, 2004, 18 (06) : 379 - 382
  • [33] Is a Two-Step Glutamate Dehyrogenase Antigen-Cytotoxicity Neutralization Assay Algorithm Superior to the Premier Toxin A and B Enzyme Immunoassay for Laboratory Detection of Clostridium difficile? (vol 46, pg 1523, 2008)
    Gilligan, Peter H.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (11) : 3872 - 3872
  • [34] Detection of EGFR Exons 18-21 Hotspot Mutations Using a Fully-Automated, Cartridge-Based Platform with Ultra-Rapid Turnaround Time: A Comparison Study with Conventional Next Generation Sequencing
    Gralewski, Jonathon
    Toth, Laura
    Judd, Andrew
    Volpicelli, Emily
    Vasef, Mohammad
    LABORATORY INVESTIGATION, 2020, 100 (SUPPL 1) : 1776 - 1777
  • [35] Rapid simultaneous extraction and magnetic particle-based enzyme immunoassay for the parallel determination of ochratoxin A, fumonisin B1 and deoxynivalenol mycotoxins in cereal samples
    Vidal, J. C.
    Bertolin, J. R.
    Ezquerra, A.
    Hernandez, S.
    Castillo, J. R.
    ANALYTICAL METHODS, 2017, 9 (24) : 3602 - 3611
  • [36] Detection of EGFR Exons 18-21 Hotspot Mutations Using a Fully-Automated, Cartridge-Based Platform with Ultra-Rapid Turnaround Time: A Comparison Study with Conventional Next Generation Sequencing
    Gralewski, Jonathon
    Toth, Laura
    Judd, Andrew
    Volpicelli, Emily
    Vasef, Mohammad
    MODERN PATHOLOGY, 2020, 33 (SUPPL 2) : 1776 - 1777