Partial Discharge Analysis for Predictive Maintenance of Generator of Geothermal Power Plant

被引:0
|
作者
Darwanto, Djoko [1 ]
Hamdani, Deny [1 ]
Hariyanto, Didik Dwi [2 ]
Karyawan, Otto Hari
机构
[1] Inst Teknol Bandung, Sch Elect Engn & Informat, Jl Ganesha 10, Bandung 40132, Indonesia
[2] PT Pertamina, Jakarta 10110, Indonesia
关键词
predictive maintenance; insulation; partial discharge; geothermal;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Generator is one of the most important apparatuses highly responsible for production process. Predictive maintainance is necessary for its high availability and reliability. It is reported that about 37% of problems of disruptive generator is caused by stator winding and about 40% of those problems is caused by disruptive insulation, to which partial discharge (PD) contributes. This paper presents partial discharge (PD) analysis for predictivie maintenance of generator of geothermal power plant. PD measurement was on-line conducted in a geothermal power plant using TGA-B IRIS Power with capacitor-coupled method and quarter system. The measurement data was used to determine PD type and its location for diagnostic purpose. Further, the analysis result and condition assessment became the basis of predictive maintenance.
引用
收藏
页码:736 / 739
页数:4
相关论文
共 50 条
  • [21] Analysis and localization of abnormal partial discharge activity in generator units
    Pemen, A. J. M.
    van der Laan, P. C. T.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2007, 17 (02): : 191 - 206
  • [22] Analysis and localization of spurious partial discharge activity in generator units
    Pemen, AJM
    van der Laan, PCT
    de Leeuw, W
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 489 - 492
  • [23] Fingerprint similarity based analysis of generator partial discharge stability
    Qian, Yong
    Huang, Cheng-Jun
    Huang, Fang-Neng
    Chen, Hong-Fu
    Chen, Chen
    Jiang, Xiu-Chen
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2007, 27 (07): : 37 - 41
  • [24] Experience with on-line Partial Discharge analysis as a tool for predictive maintenance for medium voltage (MV) switchgear systems
    Smith, JE
    Paoletti, G
    Blokhintsev, I
    INDUSTRY APPLICATIONS SOCIETY 49TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2002, : 155 - 161
  • [25] Performance analysis of the Chena binary geothermal power plant
    Aneke, Mathew
    Agnew, Brian
    Underwood, Chris
    APPLIED THERMAL ENGINEERING, 2011, 31 (10) : 1825 - 1832
  • [26] Energy, exergy, and economic analysis of a geothermal power plant
    Kazemi H.
    Ehyaei M.A.
    Advances in Geo-Energy Research, 2018, 2 (02): : 190 - 209
  • [27] Energy and Exergy Analysis of Dieng Geothermal Power Plant
    Qurrahman, Alfian Hardi
    Wilopo, Wahyu
    Susanto, Sigit Ponco
    Petrus, Himawan Tri Bayu Murti
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2021, 12 (01) : 175 - 185
  • [28] Experience of a Partial Discharge Problem of Electrical Cables in Power Plant
    Kongdang, P.
    Nganpitak, T.
    Sontayananon, N.
    Chamnong, C.
    Chuayin, C.
    Pattanadech, N.
    2018 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2018, : 700 - 703
  • [29] OPERATIONS & MAINTENANCE Monitoring of Power Station Components: Predictive Maintenance in Flexible Plant Operation
    Binder, Franz
    Power, 2022, 166 (03) : 28 - 29
  • [30] THE POWER OF PREDICTIVE MAINTENANCE
    Paré, Mathieu
    Design Engineering (Canada), 2021, 66 (05): : 24 - 25