Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies

被引:22
|
作者
Christen, Patrik [1 ]
Ito, Keita [1 ]
Mueller, Ralph [2 ]
Rubin, Mishaela R. [3 ]
Dempster, David W. [4 ]
Bilezikian, John P. [3 ]
van Rietbergen, Bert [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] ETH, Inst Biomech, CH-8093 Zurich, Switzerland
[3] Coll Phys & Surg, Dept Med, New York, NY 10032 USA
[4] Helen Hayes Hosp, Reg Bone Ctr, W Haverstraw, NY 10993 USA
基金
美国国家卫生研究院;
关键词
Bone modelling and remodelling; Bone loading; Hypoparathyroidism; TRABECULAR BONE; CANCELLOUS BONE; PARATHYROID-HORMONE; IN-VIVO; MECHANICAL STIMULATION; STRUCTURAL-PROPERTIES; MINERAL DENSITY; DISTAL RADIUS; HYPERPARATHYROIDISM; ADAPTATION;
D O I
10.1016/j.jbiomech.2012.06.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-specific predictions of bone modelling and remodelling. Based on such models, the underlying mechanisms of bone diseases and/or the effects of certain drugs and their influence on the bone micro-architecture can be investigated. In the present study we test the ability of this approach to predict changes in bone micro-architecture during hypoparathyroidism (HypoPT), as an illustrative example. We hypothesize that, apart from reducing bone turnover, HypoPT must also lead to increased osteocyte mechanosensitivity in order to explain the changes in bone mass seen in patients. Healthy human iliac crest biopsies were used as the starting point for the simulations that mimic HypoPT conditions and the resultant micro-architectures were compared to age-matched clinical HypoPT biopsies. Simulation results were in good agreement with the clinical data when osteocyte mechanosensitivity was increased by 40%. In conclusion, the results confirm our hypothesis, and also demonstrate that patient-specific bone modelling and remodelling simulations are feasible. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2411 / 2416
页数:6
相关论文
共 50 条
  • [31] Patient-specific simulation of refractive surgery: Biomechanics and modeling of CLEAR human lenticules
    Nambiar, Malavika
    Liechti, Layko
    Seiler, Theo G.
    Buchler, Philippe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [32] Parametric model of human body shape and ligaments for patient-specific epidural simulation
    Vaughan, Neil
    Dubey, Venketesh N.
    Wee, Michael Y. K.
    Isaacs, Richard
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2014, 62 (02) : 129 - 140
  • [33] Longitudinal changes between premenopausal and postmenopausal in three-dimensional trabecular microstructural characteristics of human iliac crest bone biopsies.
    Jiang, Y
    Zhao, J
    Recker, RR
    Draper, MW
    Genant, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S184 - S184
  • [34] A patient-specific modelling method of blood circulatory system for the numerical simulation of enhanced external counterpulsation
    Li, Bao
    Wang, Hui
    Li, Gaoyang
    Liu, Jian
    Zhang, Zhe
    Gu, Kaiyun
    Yang, Haisheng
    Qiao, Aike
    Du, Jianhang
    Liu, Youjun
    JOURNAL OF BIOMECHANICS, 2020, 111
  • [35] A Novel FEM Approach for Evaluating the Fracture Resistance of Human Cortical Bone Demonstrates that Material Heterogeneity Distributes and Attenuates Damage in Cortical Bone from Human Iliac Crest Biopsies
    Demirtas, Ahmet
    Taylor, Erik
    Donnelly, Eve
    Ural, Ani
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 65 - 65
  • [36] Fabrication of individual scaffolds based on a patient-specific alveolar bone defect model
    Li, Jinghui
    Zhang, Lei
    Lv, Shengyi
    Li, Shengjie
    Wang, Na
    Zhang, Zhenting
    JOURNAL OF BIOTECHNOLOGY, 2011, 151 (01) : 87 - 93
  • [37] Skeletal site-specific characterization of orofacial and iliac crest human bone marrow stromal cells in same individuals
    Akintoye, Sunday O.
    Lam, Thanh
    Shi, Songtao
    Brahim, Jaime
    Collins, Michael T.
    Robey, Pamela G.
    BONE, 2006, 38 (06) : 758 - 768
  • [38] Patient-specific anisotropic model of human trunk based on MR data
    Courchesne, Olivier
    Guibault, Francois
    Parent, Stefan
    Cheriet, Farida
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (09) : e02724
  • [39] ADJOINT BASED CALIBRATION OF COUPLED SIMULATION APPROACHES OF PATIENT-SPECIFIC VASCULAR MODELS
    Wall, Wolfgang A.
    Ismail, Mahmoud
    Maier, Andreas
    Gee, Michael W.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 903 - 904
  • [40] Numerical Simulation of Intravascular Ultrasound Images Based on Patient-Specific Computed Tomography
    van Aarle, Daniek A. C.
    Fasen, Floor
    Schmeitz, Harold A. W.
    de Bruijn, Frederik J.
    van Sambeek, Marc R. H. M.
    Schwab, Hans-Martin
    Lopata, Richard G. P.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 215 - 225