Studying the Dynamic Strain of Copper and Its Alloy by the Split Hopkinson Bar Method

被引:0
|
作者
Garmashev, Yu. A. [1 ]
Degtyaryov, A. A. [1 ]
Dolgykh, S. M. [1 ]
Klyonov, A. I. [1 ]
Petrov, D. V. [1 ]
Petukhov, E. A. [1 ]
Sidorov, K. S. [1 ]
Smirnov, E. B. [1 ]
Shistirikov, M. A. [1 ]
Yusupov, D. T. [1 ]
机构
[1] Zababakhin All Russia Res Inst Tech Phys, Russian Fed Nucl Ctr, 13 Vasilyeva St, Snezhinsk 456770, Russia
关键词
D O I
10.1063/1.5084378
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The study is undertaken in order to obtain experimental data on dynamic compression of structural materials for refining computational models that describe material behavior under dynamic loading. The task was to study the dynamic properties of a copper-tin alloy and copper MOOK in the strain rate range (epsilon) over dot = 102 10(4) s(-1). The problem of strength and failure under a single intense loading, such as shock, explosion, etc. occupies a special place in the general problem of the strength of materials and structures under dynamic loading. High strain rates or shock loading, high stress levels, high plastic strain predominantly in the isentropic process of deformation, and specific behavior of the material under such loading cause difficulties in experimental studies forming a basis for physical and mathematical models of material strain and failure that are used in structural calculations. The possibility of comparing the results of the studies and their reliability are primarily determined by the scientific validation of the setup of high-rate material tests. One of the methods having a clear theoretical basis, high efficiency, generality and reliability of the obtained results is the split Hopkinson bar (SHB) method, or the Kolsky method. This method allows one to study dynamic diagrams of compression and tension at strain rates (epsilon) over dot = 10(2) 10(4) s(-1). The paper contains the experimental results of tests on dynamic compression of copper and a copper-tin alloy performed by the SHB method. The diagrams of dynamic compression have been determined. The strain model parameters for copper and its alloy have been obtained in Johnson-Cook form widely used in dynamic calculations.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] SPECIMEN STRAIN MEASUREMENT IN SPLIT-HOPKINSON-PRESSURE-BAR EXPERIMENT
    SHARPE, WN
    HOGE, KG
    EXPERIMENTAL MECHANICS, 1972, 12 (10) : N29 - &
  • [32] A split Hopkinson pressure bar for experimental investigation of dynamic pulverization under very high strain rates
    Jayawickrama, Eranga Gayanath
    Sekiguchi, Takuma
    Muto, Jun
    Sawa, Sando
    Nagahama, Hiroyuki
    Kono, Yoshio
    Bae, Kyung-Oh
    Shin, Hyung-Seop
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (09):
  • [33] High Strain Rate Response of Rocks Under Dynamic Loading Using Split Hopkinson Pressure Bar
    Mishra S.
    Meena H.
    Parashar V.
    Khetwal A.
    Chakraborty T.
    Matsagar V.
    Chandel P.
    Singh M.
    Mishra, Sunita (sunita.mishra256@gmail.com), 2018, Springer International Publishing (36) : 531 - 549
  • [34] High Strain Rate Response of Rocks under Dynamic Loading Using Split Hopkinson Pressure Bar
    Mishra, Sunita
    Parashar, Vedant
    Chakraborty, Tanusree
    Matsagar, Vasant
    Chandel, Pradeep
    Mangla, Vikas
    Singh, Manjit
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 88 - 96
  • [35] Research on dynamic compressive behaviors of marble under high strain rates with split Hopkinson pressure bar
    Wang, Fuzeng
    Liu, Shuying
    Cao, Liang
    JOURNAL OF STRUCTURAL GEOLOGY, 2020, 138
  • [36] SPECIMEN STRAIN MEASUREMENT IN SPLIT-HOPKINSON-PRESSURE-BAR EXPERIMENT
    SHARPE, WN
    HOGE, KG
    EXPERIMENTAL MECHANICS, 1972, 12 (12) : 570 - +
  • [37] ON THE COMPRESSION TESTS OF ROCK BY THE SPLIT HOPKINSON BAR METHOD.
    Sato, Kazuhiko
    Kinoshita, Shigenori
    Nippon Kogyo Kaishi/Journal of the Mining and Metallurgical Institute of Japan, 1974, 90 (1038): : 527 - 532
  • [38] Effects of strain rate on concrete strength subjected to impact load - Dynamic compressive strength test by Split Hopkinson Pressure Bar method
    Jitsu, K
    Shirai, K
    Ito, C
    Shimamura, K
    Ohnuma, H
    STRUCTURES UNDER SHOCK AND IMPACT V, 1998, 2 : 471 - 480
  • [39] Dynamic Brazilian test of concrete using split Hopkinson pressure bar
    Xudong Chen
    Limei Ge
    Jikai Zhou
    Shengxing Wu
    Materials and Structures, 2017, 50
  • [40] Using the split Hopkinson pressure bar to investigate the dynamic behaviour of SFRC
    Lok, TS
    Zhao, PJ
    Lu, G
    MAGAZINE OF CONCRETE RESEARCH, 2003, 55 (02) : 183 - 191