EXPERIMENTAL DAMPING OF A HEAT EXCHANGE TUBE WITH A LARGE NUMBER OF SUPPORTS IN AIR AND WATER

被引:0
|
作者
Park, Tae-Jung [1 ]
Ha, Chang-Hoon [1 ]
Cho, Min-Ki [1 ]
Kang, Heung Seok [2 ]
Lee, Kang Hee [2 ]
机构
[1] Doosan Heavy Ind & Construct Co, Chang Won, South Korea
[2] KAERI, Daejeon, South Korea
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The flow induced vibration occurs frequently in a steam generator in the nuclear power plant. The large-scale steam generator has a large number of tube supports whose cell has rhombus-type shape, and there is a tiny clearance between tube and its support grid. The damping is very complex because of non-linearity and randomness. The experiment for damping was performed to investigate it with a number of 13 support spans both in air and water environment. The lower part of multi-span fixture was excited by root-mean-square random force with the range of 1 similar to 10 newton to get the frequency response function. The half-power bandwidth method was applied to obtain the damping ratio. The sensitivity of a number of spans was investigated in the range of 9 similar to 13. In addition, the damping was reviewed from a comparison with Pettigrew [1 similar to 4] and ASME B&PV Code [5].
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Water to Nanofluids heat transfer in concentric tube heat exchanger: Experimental study
    Khedkar, Rohit S.
    Sonawane, Shriram S.
    Wasewar, Kailas L.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 318 - 323
  • [22] Sensitivity Analysis for the Water-Air Heat Exchange Term
    Kalinowska, Monika B.
    Mrokowska, Magdalena M.
    Rowinski, Pawel M.
    FREE SURFACE FLOWS AND TRANSPORT PROCESSES, 2018, : 219 - 233
  • [23] APPROXIMATION OF HEAT-EXCHANGE AT AIR-WATER INTERFACE
    YOTSUKURA, N
    JACKMAN, AP
    FAUST, CR
    WATER RESOURCES RESEARCH, 1973, 9 (01) : 118 - 128
  • [24] APPROXIMATION OF HEAT-EXCHANGE AT AIR-WATER INTERFACE
    MORSE, WL
    WATER RESOURCES RESEARCH, 1973, 9 (05) : 1471 - 1473
  • [25] Experimental assessment of the replacement of a conventional fin-and-tube condenser by a minichannel heat exchanger in an air/water chiller for residential air conditioning
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    Hidalgo-Mompean, F.
    Lopez-Belchi, A.
    ENERGY AND BUILDINGS, 2017, 144 : 104 - 116
  • [26] AN EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER DURING TURBULENT FLOW OF AIR IN A CIRCULAR TUBE FOR CASE OF COOLING WITH LARGE TEMPERATURE DIFFERENCES
    ROZHDESTVENSKII, VI
    INTERNATIONAL CHEMICAL ENGINEERING, 1970, 10 (02): : 279 - +
  • [27] A study of the evaporation heat exchange characteristics of water-air annular two-phase flows in a vertical slender tube
    Yi, Jie
    Liu, Zhen-Hua
    Wang, Jing
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 2002, 17 (04): : 370 - 374
  • [28] Numerical and PIV Experimental Study on the Performance of Heat Exchange Tube With Conical Strips
    Liu, Peng
    Zheng, Nian-Ben
    Wang, Xin-Ting
    Shan, Feng
    Liu, Zhi-Chun
    Liu, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2019, 40 (02): : 382 - 388
  • [29] Experimental Study of Heat Transfer Rate in a Shell and Tube Heat Exchanger with Air Bubble Injection
    Nandan, A.
    Singh, G.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2016, 29 (08): : 1160 - 1166
  • [30] The efficiency of number of tube passes of MSF heat exchanger materials for water desalination
    Al-Faize, Mustafa M.
    Jabar, Worod M.
    MATERIALS TODAY-PROCEEDINGS, 2022, 49 : 2802 - 2805