Ambulatory follow-up of aortic dissection: Comparison between computed tomography and biplane transesophageal echocardiography

被引:9
|
作者
Maffei, S
Baroni, M
Terrazzi, M
Piacenti, M
Paoli, F
Camerini, E
Verunelli, F
Salvatore, L
Biagini, A
机构
[1] ANNUNZIATA HOSP,FLORENCE,ITALY
[2] OSPED S CHIARA,CLIN RADIOL,PISA,ITALY
[3] CISANELLO HOSP,PISA,ITALY
来源
关键词
D O I
10.1007/BF01880741
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim of the study was to assess the relative usefulness of transesophageal echocardiography (TEE) and X-ray computed tomography (CT) in the follow-up of patients who survived an aortic dissection. Materials and Methods. We evaluated 44 patients (age = 57 +/- 12 years) with treated aortic dissection: 14 had a De Bakey type I, 20 a type II and 1 patient a type III dissection treated surgically; 1 patient had a type I, 1 a type II and 7 a type III dissection treated medically. All entered an outpatient follow-up program with serial evaluations at 1, 6 and 12 months after initial diagnosis by dual noninvasive imaging protocol. A contrast-enhanced CT scan and a TEE with biplane probe were performed on the same day and in random order. Results. A total of 252 evaluations with both CT and TEE were considered. A completely normal study was found in 45 TEE and 48 CT evaluations. The following abnormal findings could be documented by one or both techniques: thrombus in the false lumen (TEE: n = 48; CT: n = 45 evaluations); intimal flap (TEE and CT: n = 68); aortic dilatation (TEE and CT: n = 15); pericardial effusion (TEE and CT: n = 3); aortic pseudoaneurysm (TEE: n = 2; CT: n = 3); isthmic coarctation (TEE and CT: n = 1). Regarding the presence or absence of these abnormalities, which are within the diagnostic domain of both imaging techniques, the results were fully concordant in 245 studies, and discordant in 7, with an overall agreement of 97%. In addition, some abnormal findings could be detected by TEE only: aortic insufficiency (n = 36); intimal tear (n = 25); spontaneous echocontrast effect in the false lumen (n = 39 evaluations). Other abnormal findings could be detected by CT only: a pleural effusion in 4, a truncus anonymous dissection in 1, a pseudoaneurysm due to suture dehiscence of the distal anastomosis of the ascending aorta in 1 evaluation (which yielded ambiguous results by TEE, with turbulent flow departing from the graft). Conclusion. Both CT and TEE are atraumatic, safe and accurate techniques for serial follow-up imaging of patients treated for aortic dissection. Information provided by CT is largely redundant, rather than additive, to that provided by TEE. The latter should be probably preferred for shorter imaging time, accuracy and convenience, although CT might still play a role in selected cases of ambiguous TEE results.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 50 条
  • [41] AORTIC ENDOCARDITIS AFTER PERCUTANEOUS BALLOON VALVULOPLASTY - THE ROLE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN EARLY DETECTION AND FOLLOW-UP
    CHIRILLO, F
    CAVARZERANI, A
    TOTIS, O
    BRUNI, A
    GIOMMI, L
    MARTON, F
    CUZZATO, V
    AMERICAN HEART JOURNAL, 1992, 124 (01) : 223 - 225
  • [42] Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography
    Andrew Jabbour
    Tevfik F Ismail
    Ali Vazir
    Isabelle Roussin
    Ankur Gulati
    Francisco Alpendurada
    Sameer Zaman
    Oluwatosin Sotubo
    Saman S Zaman
    Ashwin Krishnamoorthy
    Simon Davies
    Sanjay K Prasad
    Susanna Price
    Michael B Rubens
    Neil Moat
    Raad H Mohiaddin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [43] Computed tomography follow-up imaging of stroke
    Nguyen, BT
    Mullins, ME
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (03) : 168 - 176
  • [44] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, Oliver
    Holzamer, Andreas
    Resch, Markus
    Endemann, Dierk H.
    Nunez, Julio
    Bodi, Vicente
    Schmid, Christof
    Riegger, Guenter A. J.
    Goessmann, Holger
    Hamer, Okka
    Stroszczynski, Christian
    Luchner, Andreas
    Hilker, Michael
    Hengstenberg, Christian
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3431 - 3438
  • [45] COMPUTED TOMOGRAPHY IN FOLLOW-UP OF MEDULLOBLASTOMAS AND EPENDYMOMAS
    ENZMANN, DR
    NORMAN, D
    LEVIN, V
    WILSON, C
    NEWTON, TH
    RADIOLOGY, 1978, 128 (01) : 57 - 63
  • [46] Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography
    Husser, O.
    Holzamer, A.
    Nunez, J.
    Bodi, V.
    Schmid, C.
    Riegger, G. A. J.
    Hamer, O.
    Stroszczynski, C.
    Hilker, M.
    Hengstenberg, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 577 - 577
  • [47] False-positive Transesophageal Echocardiography after False-positive Computed Tomography Angiography in Suspected Type A Aortic Dissection
    Gologorsky, Edward
    Zhang, Qin N.
    Gologorsky, Angela
    ANESTHESIOLOGY, 2018, 129 (05) : 1028 - 1028
  • [48] VALUE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE FOLLOW-UP OF SUCCESSFUL PERCUTANEOUS MITRAL COMMISSUROTOMY
    PORTE, JM
    CORMIER, B
    IUNG, B
    DADEZ, E
    STARKMAN, C
    MICHEL, PL
    NALLET, O
    VAHANIAN, A
    ACAR, J
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (02): : 211 - 218
  • [49] Computed tomography follow-up after elective proximal aortic surgery: Less is more?
    Marreiros, Delano J. de Oliveira
    Tomsic, Anton
    van Brakel, Thomas J.
    Hamming, Jaap F.
    Scholte, Arthur J. H. A.
    Hjortnaes, Jesper
    Klautz, Robert J. M.
    AMERICAN HEART JOURNAL, 2022, 249 : 66 - 75
  • [50] Transesophageal echocardiography and unexplained cerebral ischemia: A multicenter follow-up study
    Labovitz, AJ
    AMERICAN HEART JOURNAL, 1999, 137 (06) : 1082 - 1087