Repeatability of normal multifocal VEP: Implications for detecting progression

被引:21
|
作者
Fortune, B
Demirel, S
Zhang, X
Hood, DC
Johnson, CA
机构
[1] Discoveries Sight, Legacy Clin Res & Technol Ctr, Denvers Eye Inst, Portland, OR 97232 USA
[2] Columbia Univ, Dept Psychol, New York, NY USA
关键词
electrophysiology; visual evoked potential; multi-focal VEP; glaucoma posterior segment; progression;
D O I
10.1097/00061198-200604000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the repeatability of the multifocal visual evoked potential (mfVEP) and to compare it with the repeatability of standard automated perimetry (SAP) in the same group of 50 normal controls retested after 1 year. Our second aim was to assess the repeatability of false alarm rates determined previously for the mfVEP using various cluster criteria. Methods: Fifty individuals with normal vision participated in this study (33 females and 17 males). The age range was 26.7 to 77.9 years and the group average age (+/- SD) was 51.4 (+/- 12.1) years. Pattern-reversal mfVEPs were obtained using a dartboard stimulus pattern in VERIS and two 8-minute runs per eye were averaged. The average number of days between the first and second mfVEP tests was 378 (+/- 58). SAP Visual fields were obtained within 17.4 (+/- 20.3) days of the mfVEP using the SITA-standard threshold algorithm. Repeatability of mfVEPs and SAP total deviation values were evaluated by calculating point-wise limits of agreement (LOA). Specificity (1-false alarm rate) was evaluated for a range of cluster criteria, whereby the number and probability level of the points defining a cluster were varied. Results: Point-wise LOA for the mfVEP signal-to-noise ratio (SNR) ranged from 2.0 to 4.3dB, with an average of 2.9 dB across all 60 locations. For SAP, LOA ranged from 2.4 to 8.9 dB, with an average of 4.0dB (excluding the points immediately above and below the blind spot). Clusters of abnormal points were not likely to repeat on either mfVEP or SAP. When an mfVEP abnormality was defined as the repeat presence (confirmation) of a 3-point (P < 0.05) cluster anywhere within a single hemifield, only 1 (of 200) monocular hemifield was deemed abnormal. Although the LOA of the mfVEP were similar throughout the field, the limited dynamic range of SNR at superior field locations will limit the ability to follow progression in "depth" at those locations.
引用
收藏
页码:131 / 141
页数:11
相关论文
共 50 条
  • [31] Multifocal VEP responses in glaucoma patients with unilateral hemifieid defects
    Thienprasiddhi, P
    Greenstein, VC
    Chen, C
    Karam, EZ
    Liebmann, JM
    Ritch, R
    Hood, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U496 - U496
  • [32] Multifocal VEP (mfVEP) reveals abnormal neuronal delays in diabetes
    Brian E. Wolff
    Marcus A. Bearse
    Marilyn E. Schneck
    Shirin Barez
    Anthony J. Adams
    Documenta Ophthalmologica, 2010, 121 : 189 - 196
  • [33] Reproducibility of multifocal VEP latency using different stimulus presentations
    Prema Sriram
    Alexander Klistorner
    Hemamalini Arvind
    Stuart L. Graham
    Documenta Ophthalmologica, 2012, 125 : 43 - 49
  • [34] Abnormal multifocal ERG and VEP responses in carriers of 11778 LHON
    Sutter, EE
    Berezovsky, A
    Salomao, SR
    Pereira, J
    Sadun, AA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U380 - U380
  • [35] Filtering multifocal VEP signals using Prony's method
    Fernandez, A.
    de Santiago, L.
    Blanco, R.
    Perez-Rico, C.
    Rodriguez-Ascariz, J. M.
    Barea, R.
    Miguel-Jimenez, J. M.
    Garcia-Luque, J. R.
    del Castillo, M. Ortiz
    Sanchez-Morla, E. M.
    Boquete, L.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 56 : 13 - 19
  • [36] Are multifocal VEP findings in glaucoma suspects consistent with structural findings?
    Greenstein, V
    Thienprasiddhi, P
    Chu, DH
    Ritch, R
    Liebmann, J
    Hood, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U781 - U781
  • [37] Technical Feasibility of Implementing Multifocal VEP for Multicenter Clinical Trials
    Cadavid, Diego
    Levin, Netta
    Costello, Fiona
    Rahilly, Alisa
    Klistorner, Alexandr
    NEUROLOGY, 2013, 80
  • [38] Abnormal multifocal ERG and VEP responses in carriers of 11778 LHON
    Sutter, EE
    Berezovsky, A
    Salomao, SR
    Pereira, J
    Sadun, AA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [39] Relationship between multifocal ERG and VEP components in retinitis pigmentosa
    Paris, V
    Ziccardi, L
    Stifano, G
    Montrone, L
    Gallinaro, G
    Falsini, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U577 - U577
  • [40] Effects of fixation instability on multifocal VEP (mfVEP) responses in amblyopes
    Zhang, Bin
    Stevenson, Scott S.
    Cheng, Han
    Laron, Michal
    Kumar, Girish
    Tong, Jianliang
    Chino, Yuzo M.
    JOURNAL OF VISION, 2008, 8 (03):