Microchip reversed-phase liquid chromatography with packed column and electrochemical flow cell using polystyrene/poly(dimethylsiloxane)

被引:14
|
作者
Ishida, Akihiko [1 ]
Natsume, Masamichi [1 ]
Kamidate, Tamio [1 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Div Biotechnol & Macromol Chem, Sapporo, Hokkaido 0608628, Japan
基金
日本学术振兴会;
关键词
Chip technology; Microchip LC; Pressure-driven flow; Electrochemical detection; Catechins;
D O I
10.1016/j.chroma.2008.10.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microchip pressure-driven liquid chromatography (LC) with a packed column and an electrochemical flow cell has been developed by using polystyrene (PS) and poly(dimethylsiloxane) (PDMS). The cylindrical separation column with packed octadecyl silica particles was fabricated in the PS substrate. The three electrode system (working, reference, and counter electrode) for amperometric detection was fabricated onto the PS substrate, using the Au deposition, photolithography, and chemical etching. The detector flow cell was formed by sealing the electrode system with a PDMS chip containing a channel. In this flow cell, the effect of working electrode width (in the direction of flow) on chromatographic parameters, such as peak width and peak resolution were studied in electrode width ranging 50-5000 mu m. The effect of electrode width on sensitivity (current intensity. current density, and S/N ratio) was also examined. The sensitivity was discussed by simulating the concentration profile generated around the working electrode. The effects of the column packing size and the column size on the separation efficiency were examined. In this study, a good separation of three catechins was successfully achieved and the detection limits for (+)-catechin, epicarechin, and epigallocatechin gallate were 350, 450, and 160 nM, respectively. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 50 条
  • [31] Organic solvent effects in reversed-phase liquid chromatography in relation to column testing
    K. Le Mapihan
    J. Vial
    A. Jardy
    Chromatographia, 2003, 57 : S163 - S170
  • [32] Organic solvent effects in reversed-phase liquid chromatography in relation to column testing
    Le Mapihan, K
    Vial, J
    Jardy, A
    CHROMATOGRAPHIA, 2003, 57 (Suppl 1) : S163 - S170
  • [33] Column preparation for reversed-phase high-temperature open tubular column liquid chromatography
    Nyholm, LM
    Markides, KE
    JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (01) : 11 - 20
  • [35] ANALYSIS OF PETROLEUM AND COAL LIQUID SAMPLES USING COUPLED-COLUMN CHROMATOGRAPHY TOGETHER WITH REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    KATZ, E
    OGAN, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 180 (AUG): : 30 - ANYL
  • [36] LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - NEW APPLICATIONS IN ION CHROMATOGRAPHY AND REVERSED-PHASE CHROMATOGRAPHY
    HORVAI, G
    FEKETE, J
    NIEGREISZ, Z
    TOTH, K
    PUNGOR, E
    JOURNAL OF CHROMATOGRAPHY, 1987, 385 : 25 - 32
  • [37] A TRAPPING COLUMN FOR THE COUPLING OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY
    VREULS, JJ
    GOUDRIAAN, VP
    BRINKMAN, UAT
    DEJONG, GJ
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (07): : 475 - 480
  • [38] Modelling flow rate gradient elution in reversed-phase liquid chromatography
    Louisi, A. Pappa
    Nikitas, P.
    Zitrou, A.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 305 - 310
  • [39] Comparison of the adsorption equilibrium of a few low-molecular mass compounds on a monolithic and a packed column in reversed-phase liquid chromatography
    Gritti, F
    Piatkowski, W
    Guiochon, G
    JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) : 81 - 107
  • [40] QUANTITATIVE-ANALYSIS OF ERYTHROMYCIN BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING
    CACHET, T
    DETURCK, K
    ROETS, E
    HOOGMARTENS, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (07) : 547 - 555