Accuracy of transesophageal echocardiography in preoperative determination of aortic anulus size during valve replacement

被引:7
|
作者
Abraham, TP
Kon, ND
Nomeir, AM
Cordell, AR
Kitzman, DW
机构
[1] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,CARDIOL SECT,WINSTON SALEM,NC 27157
[2] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,DEPT CARDIOTHORAC SURG,WINSTON SALEM,NC 27157
关键词
D O I
10.1016/S0894-7317(97)70087-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This prospective, blinded study evaluated the accuracy of transesophageal (TEE) and transthoracic echocardiography in predicting the size of the surgical aortic valve anulus in 20 consecutive patients undergoing aortic valve replacement. TEE was highly accurate in predicting surgical aortic valve anulus size (p = 0.98; p < 0.00001). The standard error of the TEE estimate of the size of the obturator anulus was only 0.04 mm, and in all cases the TEE estimate was within 1 mm of the direct surgical measurement. Both biplane and multiplane TEE probes were equally accurate and this accuracy was maintained over a wide range of sizes of surgical aortic anulus. Transthoracic echocardiography appeared less accurate in predicting anulus size (r = 0.64; p < 0.08). Therefore TEE can be used routinely for selection and preparation of aortic allografts before sternotomy, potentially reducing cardiopulmonary bypass pump time by 10 to 30 minutes and ensuring optimal size matching of the donor-recipient anulus.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [41] A GASTRIC LACERATION AFTER TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN A PATIENT UNDERGOING AORTIC-VALVE REPLACEMENT
    LATHAM, P
    HODGINS, LR
    [J]. ANESTHESIA AND ANALGESIA, 1995, 81 (03): : 641 - 642
  • [42] DETERMINATION OF AORTIC-VALVE ORIFICE AREA IN AORTIC-STENOSIS WITH TRANSESOPHAGEAL AND DOPPLER ECHOCARDIOGRAPHY
    KASPER, W
    GEIBEL, A
    HOFMANN, T
    BEHROZ, A
    JUST, H
    [J]. CIRCULATION, 1987, 76 (04) : 354 - 354
  • [43] Assessment of Post-Procedural Aortic Regurgitation After Transcatheter Aortic Valve Replacement During the Procedure: An Intraprocedural Transesophageal Echocardiography Study
    Mihara, Hirotsugu
    Shibayama, Kentaro
    Jilaihawi, Hasan
    Itabashi, Yuji
    Berdejo, Javier
    Utsunomiya, Hiroto
    Siegel, Robert J.
    Makkar, Raj R.
    Shiota, Takahiro
    [J]. CIRCULATION, 2014, 130
  • [44] Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: A case report
    Nakahira J.
    Ishii H.
    Sawai T.
    Minami T.
    [J]. Journal of Medical Case Reports, 9 (1)
  • [45] Less Invasive and More Efficient: Transcatheter Aortic Valve Replacement With Transthoracic Echocardiography vs. Transesophageal Echocardiography
    Vuong, Belinda W.
    Hess, Timothy
    Saari, Stacey
    Jacobson, Kurt
    Gepner, Adam D.
    [J]. CIRCULATION, 2018, 138
  • [46] Prediction of homograft aortic valve size by transthoracic and transesophageal two-dimensional echocardiography
    Fan, CM
    Liu, X
    Panidis, JP
    Wiener, DH
    Pollack, PS
    Addonizio, VP
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (04): : 345 - 348
  • [47] DETERMINATION OF AORTIC-VALVE ORIFICE AREA IN AORTIC-VALVE STENOSIS BY TWO-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    HOFMANN, T
    KASPER, W
    MEINERTZ, T
    SPILLNER, G
    SCHLOSSER, V
    JUST, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04): : 330 - 335
  • [48] The Use of Contrast May Improve Aortic Valve Assessment During Transesophageal Echocardiography
    Haas, Zachary A.
    Qian, Cheng
    Dabski, Matthew A.
    Jafarisis, Samira
    Cousins, Jonathan
    Fernandez, Stanley F.
    Nader, Nader D.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (06) : 904 - 910
  • [49] PROGNOSIS OF AORTIC-VALVE REPLACEMENT IN RELATION TO PREOPERATIVE HEART SIZE
    BRAUN, LO
    KINCAID, OW
    MCGOON, DC
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 65 (03): : 381 - 385
  • [50] Preoperative echocardiographic prediction of small prosthesis size for aortic valve replacement
    BechHanssen, O
    Caidahl, K
    Myken, PSU
    Kjellman, U
    Larsson, S
    Wallentin, I
    [J]. JOURNAL OF HEART VALVE DISEASE, 1996, 5 (02): : 128 - 135