NMR imaging of thermally polarized helium-3 gas

被引:16
|
作者
Kober, F
Koenigsberg, B
Belle, V
Viallon, M
Leviel, JL
Delon, A
Ziegler, A
Décorps, M
机构
[1] Univ Grenoble 1, LRC, CEA, LCHU,INSERM,U438, F-38043 Grenoble 9, France
[2] Univ Lyon 1, CNRS, F-69622 Villeurbanne, France
[3] LCMI, CNRS, UPR 5021, F-38042 Grenoble 9, France
关键词
NMR; MRI; helium; diffusion; lung imaging;
D O I
10.1006/jmre.1999.1756
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is shown that thermally polarized He-3 gas can be used to measure important physical parameters and to design, test, and tune imaging sequences. The bulk values of T-1, T-2, and the diffusion coefficient were measured in a glass cell containing a mixture of helium-3 (0.8 bar) and oxygen (0.2 bar). They were found to be T-1 = 7 s, T-2 = 2.4 s, and D = 1.6 cm(2) s(-1). The relaxation times T-2* and T-1 and the apparent diffusion coefficient of thermally polarized helium-3 gas were measured in the rat lung, and these parameters were used to design a helium-3 optimized multi-spin-echo sequence which was shown to increase the signal-to-noise ratio sufficiently to obtain the first NMR-images of thermally polarized helium-3 in the rat lung, (C) 1999 Academic Press.
引用
收藏
页码:308 / 312
页数:5
相关论文
共 50 条
  • [31] NMR dynamics with large dipolar interactions in liquid helium-3 films
    Nacher, PJ
    Marion, F
    Villard, B
    Tastevin, G
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2002, 126 (1-2) : 85 - 90
  • [32] Universal Gas Installation with the Function of Recovering and Cleaning Helium-3
    Glushkova, T. I.
    Kochenda, L. M.
    Kravtsov, P. A.
    Fetisov, A. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (01) : 157 - 162
  • [33] Parallel imaging of hyperpolarized helium-3 with simultaneous slice excitation
    Teh, K
    Lee, KJ
    Paley, MNJ
    Wild, JM
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) : 258 - 262
  • [34] Airway imaging in humans using hyperpolarized helium-3 MRI
    McKinstry, EL
    Tooker, AC
    Hong, KS
    Costello, P
    Jolesz, FA
    Albert, MS
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 923 - 924
  • [35] In vivo oxygen tension mapping with helium-3 MR imaging
    Roberts, TP
    Kauczor, HU
    Surkau, R
    Grossmann, T
    Thelen, M
    RADIOLOGY, 1997, 205 : 1388 - 1388
  • [36] Probing the micropores in Linde-type A zeolites by helium-3 NMR
    Hayashi, S
    CHEMISTRY LETTERS, 2006, 35 (01) : 92 - 93
  • [37] NMR shielding in helium-3 atoms modified by gaseous nitrogen and oxygen
    Garbacz, Piotr
    Misiak, Maria
    Jackowski, Karol
    MAGNETIC RESONANCE IN CHEMISTRY, 2020, 58 (08) : 745 - 749
  • [38] A study of final. state effects in the electrodisintegration of a polarized helium-3 target
    Kievsky, A
    Pace, E
    Salmé, G
    GDH 2004: PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON THE GERASIMOV-DRELL-HEARN SUM RULE AND ITS EXTENSIONS, 2005, : 312 - 319
  • [39] A NMR spectrometer for superfluid helium-3 study at very low temperatures
    Medeová, M
    Skyba, P
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 : A149 - A152
  • [40] Hyperpolarized helium-3 MR imaging of asthma induction and reversal
    Altes, TA
    Samee, S
    Ciambotti, JM
    Mata, JF
    Platts-Mills, T
    De Lange, EE
    RADIOLOGY, 2002, 225 : 347 - 347